Surface morphology optimization for osseointegration of coated implants
Abstract
This paper aims to establish a relationship between the surface morphology induced micromechanics and bone remodeling responses to a solid bead coated porous implant and further to develop a multiobjective optimization framework for the coating design of biomaterials. Multiscale modeling and remodeling techniques were developed, where a macroscopic analysis was initially performed to generate a global response to enable a microscopic analysis. The bone remodeling responses of the microscopic models (with a specific surface morphology) were evaluated in terms of the average apparent density developed in the peri-implant region. To explore the proposed multiscale analysis and design methods, a typical dental implantation setting is exemplified in this study. The response surface method (RSM) was utilized to relate the major implant coating parameters to the bone responses. It is found that increasing the volume fraction of the coating beads/particles results in a greater bone density, whereas increasing bead/particle size does not significantly affect the bone's responses. Several different multiobjective optimization schemes were adopted to optimize the coated bead size and volume fraction, which reveal that the optimal design parameters of particle diameter and volume fraction are 100 microm--35% and 38 microm--17.5% for the cortical and cancellous bones respectively, agreeing with clinical data. To maximize the implant/bone interfacial stability, specific surface coating des…
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Titanium implants used for bone tissue replacement show higher osseointegration when the surface is modified to permit attachment and migration of bone-forming cells.
“For example, titanium implants used for bone tissue replacement (e.g., hip/knee replacements, dental implants) show higher osseointegration when the surface is modified to permit attachment and migration of bone forming cells [87,88].”
From Biomaterial based modulation of macrophage polarization: a review and suggested design principles (2015) · cites this paper as [88]
Cites
Response Surface Methodology: Process and Product Optimization Using Designed Experiments
Gunst, R. F., Myers, R. H., & Montgomery, D. C. (1996) · Technometrics · doi:10.2307/1270613 · Cited by 9,576 · see citing works
Response Surface Methodology: Process and Product Optimization Using Designed Experiments
Gunst, R. F. (1996) · Technometrics · doi:10.1080/00401706.1996.10484509 · Cited by 3,302 · see citing works
MOPSO: a proposal for multiple objective particle swarm optimization
Coello, C. A. C., & Lechuga, M. S. (2002) · IEEE Congress on Evolutionary Computation (CEC) · doi:10.1109/cec.2002.1004388 · Cited by 2,457 · see citing works
Adaptive bone-remodeling theory applied to prosthetic-design analysis
Huiskes, R., Weinans, H., Grootenboer, H. J., Dalstra, M., Fudala, B., & Slooff, T. J. J. H. (1987) · Journal of Biomechanics · doi:10.1016/0021-9290(87)90030-3 · Cited by 1,175 · see citing works
Application of finite element analysis in implant dentistry: A review of the literature
Geng, J., Tan, K. B. C., & Liu, G. (2001) · Journal of Prosthetic Dentistry · doi:10.1067/mpr.2001.115251 · Cited by 1,107 · see citing works
Advancing dental implant surface technology – From micron- to nanotopography
Mendonça, G., Mendonça, D. B. S., Aragão, F. J. L., et al. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.05.012 · Cited by 992 · see citing works
The Optimum Pore Size for the Fixation of Porous-Surfaced Metal Implants by the Ingrowth of Bone
Bobyn, J., Pilliar, R. M., Cameron, H. U., et al. (1980) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198007000-00045 · Cited by 833 · see citing works
Relations of mechanical properties to density and CT numbers in human bone
Rho, J. Y., Tho, M. H. B., & ASHMAN, R. B. (1995) · Medical Engineering & Physics · doi:10.1016/1350-4533(95)97314-f · Cited by 825 · see citing works
Application of porous ceramics for the attachment of load bearing internal orthopedic applications
Klawitter, J. J., & Hulbert, S. (1971) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820050613 · Cited by 635 · see citing works
The behavior of adaptive bone-remodeling simulation models
Weinans, H., Huiskes, R., & Grootenboer, H. J. (1992) · Journal of Biomechanics · doi:10.1016/0021-9290(92)90056-7 · Cited by 634 · see citing works
An effective use of crowding distance in multiobjective particle swarm optimization
Raquel, C. R., & Naval, P. C. (2005) · Genetic and Evolutionary Computation Conference (GECCO) · doi:10.1145/1068009.1068047 · Cited by 625 · see citing works
Dental Materials and Their Selection
O’Brien, W. J. (2009) · Cited by 569 · see citing works
Mechanical loading histories and cortical bone remodeling
Carter, D. R. (1984) · Calcified Tissue International · doi:10.1007/bf02406129 · Cited by 490 · see citing works
Pore diameter of more than 100 μm is not requisite for bone ingrowth in rabbits
Itälä, A., Ylänen, H. O., Ekholm, C., Karlsson, K. H., & Aro, H. T. (2001) · Journal of Biomedical Materials Research · doi:10.1002/jbm.1069 · Cited by 379 · see citing works
Osseointegrated titanium fixtures in the treatment of edentulousness
Brånemark, P., Adell, R., Albrektsson, T. O., et al. (1983) · Biomaterials · doi:10.1016/0142-9612(83)90065-0 · Cited by 345 · see citing works
A Comparison of Endosseous Dental Implant Surfaces
Cochran, D. L. (1999) · Journal of Periodontology · doi:10.1902/jop.1999.70.12.1523 · Cited by 331 · see citing works
Schenk, R., & Buser, D. (1998) · Periodontology 2000 · doi:10.1111/j.1600-0757.1998.tb00120.x · Cited by 301 · see citing works
Platelet interactions with titanium: modulation of platelet activity by surface topography
Park, J. Y., Gemmell, C. H., & Davies, J. E. (2001) · Biomaterials · doi:10.1016/s0142-9612(01)00009-6 · Cited by 297 · see citing works
A NOTE ON WEIGHTED CRITERIA METHODS FOR COMPROMISE SOLUTIONS IN MULTI-OBJECTIVE OPTIMIZATION
Athan, T. W., & Papalambros, P. Y. (1996) · Engineering Optimization · doi:10.1080/03052159608941404 · Cited by 273 · see citing works
Design optimization of regular hexagonal thin-walled columns with crashworthiness criteria
Hou, S., Li, Q., Long, S., et al. (2007) · Finite Elements in Analysis and Design · doi:10.1016/j.finel.2006.12.008 · Cited by 269 · see citing works
Self-citationEfficient 3D finite element analysis of dental restorative procedures using micro-CT data
Magne, P. (2006) · Dental Materials · doi:10.1016/j.dental.2006.03.013 · Cited by 257 · see citing works
Processing and mechanical properties of autogenous titanium implant materials
Wen, C., Yamada, Y., Shimojima, K., Chino, Y., Asahina, T., & Mabuchi, M. (2002) · Journal of Materials Science Materials in Medicine · doi:10.1023/a:1014344819558 · Cited by 256 · see citing works
Multiobjective optimization of multi-cell sections for the crashworthiness design
Hou, S., Li, Q., Long, S., et al. (2008) · International Journal of Impact Engineering · doi:10.1016/j.ijimpeng.2007.09.003 · Cited by 249 · see citing works
Self-citationO'Mahony, A. M., Williams, J. L., & Spencer, P. (2001) · Clinical Oral Implants Research · doi:10.1034/j.1600-0501.2001.120614.x · Cited by 247 · see citing works
Effect of surface finish on the osseointegration of laser-treated titanium alloy implants
Götz, H., Müller, M., Emmel, A., Holzwarth, U., Erben, R. G., & Stangl, R. (2003) · Biomaterials · doi:10.1016/j.biomaterials.2003.11.002 · Cited by 241 · see citing works
Growth of bone marrow cells on porous ceramics in vitro
Uchida, A., Nade, S., McCartney, E. R., & Ching, W. (1987) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820210106 · Cited by 233 · see citing works
Frost, H. M. (1965) · The American Journal of the Medical Sciences · doi:10.1097/00000441-196502000-00053 · Cited by 227 · see citing works
Dental materials and their selection
Grunnleggende om materialerW.J. O’Brien, E., & Øilo, M. (2009) · Den Norske tannlegeforenings tidende · doi:10.56373/2009-5-27 · Cited by 220 · see citing works
The rate of bone ingrowth into porous metal
Camron, H. U., Pilliar, R. M., & Macnab, I. (1976) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820100210 · Cited by 210 · see citing works
A mathematical model for simulating the bone remodeling process under mechanical stimulus
Li, J., Li, H., Shi, L., et al. (2006) · Dental Materials · doi:10.1016/j.dental.2006.10.004 · Cited by 209 · see citing works
Anisotropic elastic properties of cancellous bone from a human edentulous mandible
O'Mahony, A. M., Williams, J. L., Katz, J. O., et al. (2000) · Clinical Oral Implants Research · doi:10.1034/j.1600-0501.2000.011005415.x · Cited by 201 · see citing works
Effects of material properties of femoral hip components on bone remodeling
Weinans, H., Huiskes, R., & Grootenboer, H. J. (1992) · Journal of Orthopaedic Research® · doi:10.1002/jor.1100100614 · Cited by 194 · see citing works
Ultrastructural characterization of the implant/bone interface of immediately loaded dental implants
Meyer, U. J., Joos, U., Mythili, J., et al. (2003) · Biomaterials · doi:10.1016/j.biomaterials.2003.08.070 · Cited by 175 · see citing works
Bone response to calcium phosphate-coated and bisphosphonate-immobilized titanium implants
Yoshinari, M., Oda, Y., Inoue, T., et al. (2002) · Biomaterials · doi:10.1016/s0142-9612(01)00415-x · Cited by 174 · see citing works
Mandibular bone remodeling induced by dental implant
Lin, D., Li, Q., Li, W., et al. (2009) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2009.08.024 · Cited by 155 · see citing works
Self-citationPorous‐surfaced metallic implants for orthopedic applications
Pilliar, R. M. (1987) · Journal of Biomedical Materials Research · doi:10.1002/j.1097-4636.1987.tb00003.x · Cited by 146 · see citing works
Microstructure and mechanical properties of plasma sprayed HA/YSZ/Ti–6Al–4V composite coatings
Khor, K. A., Gu, Y., Pan, D., et al. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2003.10.089 · Cited by 138 · see citing works
Mechanics considerations for microporous titanium as an orthopedic implant material
Thelen, S., Barthelat, F., & Brinson, L. C. (2004) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.20100 · Cited by 136 · see citing works
Numerical modeling of pore size and distribution in foamed titanium
Shen, H., Oppenheimer, S., Dunand, D. C., et al. (2005) · Mechanics of Materials · doi:10.1016/j.mechmat.2005.06.027 · Cited by 115 · see citing works
Finite element modeling of porous titanium
Shen, H., & Brinson, L. C. (2006) · International Journal of Solids and Structures · doi:10.1016/j.ijsolstr.2006.04.020 · Cited by 103 · see citing works
Li, H., Oppenheimer, S., Stupp, S. I., et al. (2004) · MATERIALS TRANSACTIONS · doi:10.2320/matertrans.45.1124 · Cited by 98 · see citing works
Finite element analysis of crestal bone loss around porous‐coated dental implants
Vaillancourt, H., Pilliar, R. M., & McCammond, D. (1995) · Journal of Applied Biomaterials · doi:10.1002/jab.770060408 · Cited by 82 · see citing works
A Histological Comparison in the Dog of Porous-coated vs. Threaded Dental Implants
Deporter, D. A., Watson, P., Pilliar, R. M., Chipmani, M. L., & Valiquette, N. (1990) · Journal of Dental Research · doi:10.1177/00220345900690050401 · Cited by 78 · see citing works
Xiropaidis, A. V., Qahash, M., Lim, W. H., et al. (2005) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2005.01126.x · Cited by 77 · see citing works
Cook, S. D., WEINSTEIN, A. M., & Klawitter, J. J. (1982) · Journal of Dental Research · doi:10.1177/00220345820610010501 · Cited by 75 · see citing works
Knabe, C., Howlett, C. R., Klar, F., et al. (2004) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30130 · Cited by 74 · see citing works
Towards automated 3D finite element modeling of direct fiber reinforced composite dental bridge
Li, W., Swain, M. V., Li, Q., et al. (2005) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.30233 · Cited by 71 · see citing works
Self-citationRosa, A. L., Crippa, G. E., de Oliveira, P. T., et al. (2009) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2008.01662.x · Cited by 62 · see citing works
Fibre reinforced composite dental bridge. Part II: numerical investigation
Li, W., Swain, M. V., Li, Q., et al. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2004.01.011 · Cited by 51 · see citing works
Self-citationFibre reinforced composite dental bridge.
Li, W., Swain, M. V., Li, Q., et al. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2004.01.010 · Cited by 45 · see citing works
Self-citationKutty, M. G., & Bhaduri, S. B. (2004) · Journal of Materials Science Materials in Medicine · doi:10.1023/b:jmsm.0000011815.50383.bd · Cited by 42 · see citing works
Al-Sayyed, A. A., Deporter, D. A., Pilliar, R. M., et al. (1994) · Clinical Oral Implants Research · doi:10.1034/j.1600-0501.1994.050303.x · Cited by 39 · see citing works
Shen, H., Li, H., & Brinson, L. C. (2008) · Mechanics of Materials · doi:10.1016/j.mechmat.2008.03.009 · Cited by 38 · see citing works
Effect of Particle Size of Fully Porous-Coated (FPC) Implants on Osseointegration
Rungsiyakull, C., Li, Q., Li, W., et al. (2008) · Advanced materials research · doi:10.4028/www.scientific.net/amr.47-50.916 · Cited by 3 · see citing works
Self-citation
Flagged first, then by citations
Cited by
Sorted by citations
Franz, S., Rammelt, S., Scharnweber, D., & Simon, J. C. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2011.05.078 · Cited by 1,391 · see citing works
Biomaterial based modulation of macrophage polarization: a review and suggested design principles
Sridharan, R., Cameron, A. R., Kelly, D. J., Kearney, C. J., & O’Brien, F. J. (2015) · Materials Today · doi:10.1016/j.mattod.2015.01.019 · Cited by 826 · see citing works
Ma, Q.-L., Zhao, L.-Z., Liu, R.-R., Jin, B.-Q., Song, W., Wang, Y., Zhang, Y.-S., Chen, L.-H., & Zhang, Y.-M. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2014.08.025 · Cited by 319 · see citing works
- Authors
- Rungsiyakull, C., Li, Q., Sun, G., Li, W., & Swain, M. V.
- Affiliations
- The University of Sydney (AU)
- Corresponding author
- Swain, Michael V.
- Venue
- Biomaterials
- Publisher
- Elsevier BV
- Published
- 2010-09
- Volume
- 31
- Issue
- 27
- Pages
- 7196-7204
- ISSN
- 0142-9612 (ISSN-L)
- OpenAlex
- W2151613878
- Cited by
- 105
- References
- 54
- Citations by year
- 2026: 1 · 2025: 7 · 2024: 5 · 2023: 4 · 2022: 4 · 2021: 6 · 2020: 4 · 2019: 12 · 2018: 6 · 2017: 9 · 2016: 8 · 2015: 11 · 2014: 8 · 2013: 10 · 2012: 4
- FWCI
- 6.22
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- Biomaterials (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Australian Research Council (DP1095140)
- Topics
- Health Sciences › Dentistry › Oral Surgery › Dental Implant Techniques and Outcomes
- Physical Sciences › Engineering › Biomedical Engineering › Bone Tissue Engineering Materials
- Health Sciences › Medicine › Surgery › Orthopaedic implants and arthroplasty
- Keywords
- osseointegration, coated implants, surface morphology, bone remodeling, porous implants, multiscale modeling, multi-objective optimization, response surface methodology, particle size, dental implants, peri-implant bone density, cortical and cancellous bone, bone-implant interface
- MeSH terms
- Models, Theoretical, Surface Properties, Dental Implants, Osseointegration, Dental Prosthesis Design, Prostheses and Implants, Coated Materials, Biocompatible
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review