Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 171

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Accuracy of drilling guides for transfer from three‐dimensional CT‐based planning to placement of zygoma implants in human cadavers

Van Steenberghe, Daniel, Malevez, Chantal, Van Cleynenbreugel, Johan, Serhal, Charbel Bou, Dhoore, Ellen, Schutyser, Filip, Suetens, Paul, Jacobs, Reinhilde·2003·Clinical Oral Implants Research

Abstract

Abstract: The accuracy of surgical drilling guides was assessed for placement of zygoma implants. Six zygoma fixtures of length 45 mm (Nobel Biocare, Göteborg, Sweden) were placed in three formalin‐fixed human cadavers using surgical drilling guides. The fabrication of these custom‐made drilling guides was based on three‐dimensional computerized tomography (3D‐CT) data for the maxillary‐zygomatic complex. The installation of the implants was simulated preoperatively using an adopted 3D‐CT planning system. In addition, anatomical measurements of the zygomatic bone were performed on the 3D images. The preoperative CT images were then matched with postoperative ones in order to assess the deviation between the planned and installed implants. The angle between the planned and actually placed implants was < 3° in four out of six cases. The largest deviation found at the exit point of one of the six implants was 2.7 mm. The present study showed that the use of surgical drilling guides should be encouraged for zygoma implant placement because of the lengths of the implants involved and the anatomical intricacies of the region.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1034/j.1600-0501.2003.140118.x

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 171

Metadata

Authors
Van Steenberghe, D., Malevez, C., Van Cleynenbreugel, J., Serhal, C. B., Dhoore, E., Schutyser, F., Suetens, P., & Jacobs, R.
Venue
Clinical Oral Implants Research
Publisher
Wiley
Published
2003-01-31
Volume
14
Issue
1
Pages
131-136
ISSN
  • 0905-7161 (ISSN-L)
  • 1600-0501
OpenAlex
W2040576051
Cited by
171
References
1
FWCI
8.50
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Accuracy of drilling guides for transfer from three‐dimensional CT‐based planning to placement of zygoma implants in human cadavers. https://app.cochat.ai/papers/10.1034/j.1600-0501.2003.140118.x
The paper
Van Steenberghe, D., Malevez, C., Van Cleynenbreugel, J., Serhal, C. B., Dhoore, E., Schutyser, F., Suetens, P., & Jacobs, R. (2003). Accuracy of drilling guides for transfer from three‐dimensional CT‐based planning to placement of zygoma implants in human cadavers. Clinical Oral Implants Research. https://doi.org/10.1034/j.1600-0501.2003.140118.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.