The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Accuracy of implant placement based on pre‐surgical planning of three‐dimensional cone‐beam images: a pilot study
Open accessAbstract
Aim: To evaluate the precision of transfer of a computer‐based three‐dimensional (3D) planning, using re‐formatted cone‐beam images, for oral implant placement in partially edentulous jaws. Material and Methods: Four formalin‐fixed cadaver jaws were imaged in a 3D Accuitomo FPD® cone‐beam computed tomography (CT). Data were used to produce an accurate implant planning with a transfer to surgery by means of stereolithographic drill guides. Pre‐operative cone‐beam CT images were subsequently matched with post‐operative ones to calculate the deviation between planned and installed implants. Results: Placed implants (length: 10–15 mm) showed an average angular deviation of 2° (SD: 0.8, range: 0.7–4.0°) as compared with the planning, while the mean linear deviation was 1.1 mm (SD: 0.7 mm, range 0.3–2.3 mm) at the hex and 2.0 mm (SD: 0.7 mm, range 0.7–2.4 mm) at the tip. Conclusions: Cone‐beam images could be used for implant planning, taking into account a maximal 4° angular and 2.4 mm linear deviation at the apical tip.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Multimodality image registration by maximization of mutual information
Maes, F., Collignon, A., Vandermeulen, D., Marchal, G., & Suetens, P. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.563664 · Cited by 4,547
Clinical applications of cone-beam computed tomography in dental practice.
Scarfe, W. C., Farman, A. G., & Sukovic, P. (2006) · PubMed · Cited by 1,528
A new volumetric CT machine for dental imaging based on the cone-beam technique: preliminary results
Mozzo, P., Procacci, C., Tacconi, A., Tinazzi Martini, P., & Bergamo Andreis, I. A. (1998) · European Radiology · doi:10.1007/s003300050586 · Cited by 1,383
Lascala, C., Panella, J., & Marques, M. (2004) · Dentomaxillofacial Radiology · doi:10.1259/dmfr/25500850 · Cited by 564
State-of-the-art on cone beam CT imaging for preoperative planning of implant placement
Guerrero, M. E., Jacobs, R., Loubele, M., Schutyser, F., Suetens, P., & van Steenberghe, D. (2006) · Clinical Oral Investigations · doi:10.1007/s00784-005-0031-2 · Cited by 371
Self-citationComputer-assisted planning of oral implant surgery: a three-dimensional approach.
Verstreken, K., Cleynenbreugel, J. V., Marchal, G., Naert, I., Suetens, P., & van Steenberghe, D. (1996) · PubMed · Cited by 172
Van Steenberghe, D., Malevez, C., Van Cleynenbreugel, J., Serhal, C. B., Dhoore, E., Schutyser, F., Suetens, P., & Jacobs, R. (2003) · Clinical Oral Implants Research · doi:10.1034/j.1600-0501.2003.140118.x · Cited by 171
Self-citationAssessment of bone segmentation quality of cone-beam CT versus multislice spiral CT: a pilot study
Loubele, M., Maes, F., Schutyser, F., Marchal, G., Jacobs, R., & Suetens, P. (2006) · Oral Surgery, Oral Medicine, Oral Pathology, Oral Radiology, and Endodontology · doi:10.1016/j.tripleo.2005.10.039 · Cited by 168
Self-citationFortin, T., Champleboux, G., Bianchi, S. D., Buatois, H., & Coudert, J. (2002) · Clinical Oral Implants Research · doi:10.1034/j.1600-0501.2002.130612.x · Cited by 146
In‐vitro assessment of a registration protocol for image guided implant dentistry
Birkfellner, W., Solar, P., Gahleitner, A., Huber, K., Kainberger, F., Kettenbach, J., Homolka, P., Diemling, M., Watzek, G., & Bergmann, H. (2001) · Clinical Oral Implants Research · doi:10.1034/j.1600-0501.2001.012001069.x · Cited by 97
Cited by
Schneider, D., Marquardt, P., Zwahlen, M., & Jung, R. E. (2009) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2009.01788.x · Cited by 477
Additive manufacturing of ceramics for dental applications: A review
Galante, R., Figueiredo-Pina, C. G., & Serro, A. P. (2019) · Dental Materials · doi:10.1016/j.dental.2019.02.026 · Cited by 441
Metadata
- Authors
- Van Assche, N., Van Steenberghe, D., Guerrero, M. E., Hirsch, E., Schutyser, F., Quirynen, M., & Jacobs, R.
- Venue
- Journal of Clinical Periodontology
- Publisher
- Wiley
- Published
- 2007-08-16
- Volume
- 34
- Issue
- 9
- Pages
- 816-821
- ISSN
- 0303-6979 (ISSN-L)
- 1600-051X
- OpenAlex
- W2103542049
- Cited by
- 318
- References
- 11
- FWCI
- 20.59
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Accuracy of implant placement based on pre‐surgical planning of three‐dimensional cone‐beam images: a pilot study. https://app.cochat.ai/papers/10.1111/j.1600-051x.2007.01110.x
- The paper
- Van Assche, N., Van Steenberghe, D., Guerrero, M. E., Hirsch, E., Schutyser, F., Quirynen, M., & Jacobs, R. (2007). Accuracy of implant placement based on pre‐surgical planning of three‐dimensional cone‐beam images: a pilot study. Journal of Clinical Periodontology. https://doi.org/10.1111/j.1600-051x.2007.01110.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.