The DOI matches its Crossref record.
The mucosal attachment to titanium implants with different surface characteristics: an experimental study in dogs
Abstract
Background: Findings from in vitro studies have indicated that the orientation and proliferation of cells on titanium surfaces may be influenced by the topography of the surface on which they are grown. It may be argued, therefore, that differences may occur in the mucosal attachment to titanium implants with different surface roughness. Aim: The present experiment was performed to study the composition of the soft tissue barrier that formed to implants prepared with well‐defined smooth or rough surfaces. Material and Methods: Five beagle dogs were used. Four implants made of c.p. titanium were placed in the right edentulous mandibular premolar region. After 3 months, two different types of abutments were connected: one experimental (OA) with a dual, thermal acid‐etched surface (‘Osseotite®’), and one regular (RA) abutment with a ‘turned’ surface. At the end of a 6‐month period during which proper plaque control had been maintained, biopsies including the implant and the surrounding soft and hard tissues were obtained, decalcified and processed for light and electron microscopy. A confocal He–Ne laser profilometer was used to study the surface topography of the abutments. Results: The attachment between the peri‐implant mucosa and titanium abutments with either a turned (RA; ‘smooth’) or acid‐etched (OA; ‘rough’) surface was similar from both a quantitative and a qualitative aspect. The attachment comprised a barrier epithelium and a zone of connective tissue attachment of similar dimension at RA and OA. It was further observed that the ‘inner’ zone of the connective tissue attachment at both types of abutment was composed of about 30–33% fibroblasts and 63–66% collagen. Conclusion: It was demonstrated that the soft tissue attachment that formed to implants made of c.p. titanium was not influenced by the roughness of the titanium surface.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Soft tissue wound healing around teeth and dental implants
Sculean, A., Gruber, R., & Bosshardt, D. D. (2014) · Journal of Clinical Periodontology · doi:10.1111/jcpe.12206 · Cited by 439
Rompen, E., Domken, O., Degidi, M., Farias Pontes, A. E., & Piattelli, A. (2006) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2006.01367.x · Cited by 356
Morphogenesis of the peri‐implant mucosa: an experimental study in dogs
Berglundh, T., Abrahamsson, I., Welander, M., Lang, N. P., & Lindhe, J. (2007) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2006.01380.x · Cited by 302
Self-citationThe mucosal barrier at implant abutments of different materials
Welander, M., Abrahamsson, I., & Berglundh, T. (2008) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2008.01543.x · Cited by 293
Self-citationSurface treatments and roughness properties of Ti-based biomaterials
Bagno, A., & Di Bello, C. (2004) · Journal of Materials Science: Materials in Medicine · doi:10.1023/b:jmsm.0000042679.28493.7f · Cited by 282
Metadata
- Authors
- Abrahamsson, I., Zitzmann, N. U., Berglundh, T., Linder, E., Wennerberg, A., & Lindhe, J.
- Venue
- Journal of Clinical Periodontology
- Publisher
- Wiley
- Published
- 2002-05
- Volume
- 29
- Issue
- 5
- Pages
- 448-455
- ISSN
- 0303-6979 (ISSN-L)
- 1600-051X
- OpenAlex
- W2062131397
- Cited by
- 194
- References
- 0
- FWCI
- 3.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The mucosal attachment to titanium implants with different surface characteristics: an experimental study in dogs. https://app.cochat.ai/papers/10.1034/j.1600-051x.2002.290510.x
- The paper
- Abrahamsson, I., Zitzmann, N. U., Berglundh, T., Linder, E., Wennerberg, A., & Lindhe, J. (2002). The mucosal attachment to titanium implants with different surface characteristics: an experimental study in dogs. Journal of Clinical Periodontology. https://doi.org/10.1034/j.1600-051x.2002.290510.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.