The DOI matches its Crossref record.
Formation of Strong Airway Irritants in Terpene/Ozone Mixtures
Open accessAbstract
The American Society for Testing and Materials (ASTM) mouse bioassay, which quantifies airway irritation from reduction in the respiratory rate, was used to find evidence for the formation of highly irritating substances in reactions of ozone with terpenes (common indoor volatile organic compounds (VOCs)). No-observed-effect-levels (NOELs) and concentration-effect relationships were established for ozone, (+)-alpha-pinene and R-(+)-limonene, isoprene, and some of their major reaction products. Reaction mixtures of excess terpene and ozone considerably below their NOEL concentrations resulted in significant upper airway irritation. The reduction of the respiratory rate was from 30% to about 50%, lowest for the alpha-pinene and highest for the isoprene mixture. Chemical analysis of reaction mixtures by conventional methods showed that readily identified stable products and residual reactants at the concentrations found could not account for the observed reductions of the respiratory rate, assuming additivity of the reaction products. The results suggest that, in addition to known irritants (formaldehyde, acrolein, methacrolein, methyl vinylketone), one or more strong airway irritant(s) of unknown structure(s) were formed. Future indoor air quality (IAQ) guidelines for unsaturated VOCs (e.g., terpenes) and their emission from building products may require the consideration of reactions with oxidants, like ozone. Similarly, effects of ozone-emitting equipment should be re-evaluated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Formaldehyde in the Indoor Environment
Salthammer, T., Mentese, S., & Marutzky, R. (2010) · Chemical Reviews · doi:10.1021/cr800399g · Cited by 1,808
Sarigiannis, D. A., Karakitsios, S. P., Gotti, A., Liakos, I. L., & Katsoyiannis, A. (2011) · Environment International · doi:10.1016/j.envint.2011.01.005 · Cited by 522
Wolkoff, P., Wilkins, C. K., Clausen, P. A., & Nielsen, G. D. (2006) · Indoor Air · doi:10.1111/j.1600-0668.2005.00393.x · Cited by 348
Self-citationIndoor secondary pollutants from cleaning product and air freshener use in the presence of ozone
Singer, B. C., Coleman, B. K., Destaillats, H., Hodgson, A. T., Lunden, M. M., Weschler, C. J., & Nazaroff, W. W. (2006) · Atmospheric Environment · doi:10.1016/j.atmosenv.2006.06.005 · Cited by 330
Singer, B. C., Destaillats, H., Hodgson, A. T., & Nazaroff, W. W. (2006) · Indoor Air · doi:10.1111/j.1600-0668.2005.00414.x · Cited by 324
Metadata
- Authors
- WOLKOFF, P., CLAUSEN, P. A., WILKINS, C. K., & NIELSEN, G. D.
- Venue
- Indoor Air
- Publisher
- Hindawi Limited
- Published
- 2000-06
- Volume
- 10
- Issue
- 2
- Pages
- 82-91
- ISSN
- 0905-6947 (ISSN-L)
- OpenAlex
- W2164536739
- Cited by
- 253
- References
- 0
- FWCI
- 8.13
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Formation of Strong Airway Irritants in Terpene/Ozone Mixtures. https://app.cochat.ai/papers/10.1034/j.1600-0668.2000.010002082.x
- The paper
- WOLKOFF, P., CLAUSEN, P. A., WILKINS, C. K., & NIELSEN, G. D. (2000). Formation of Strong Airway Irritants in Terpene/Ozone Mixtures. Indoor Air. https://doi.org/10.1034/j.1600-0668.2000.010002082.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.