CoChat

Formation of Strong Airway Irritants in Terpene/Ozone Mixtures

Open access
WOLKOFF, P., CLAUSEN, P. A., WILKINS, C. K., NIELSEN, G. D. · 2000 · Indoor Air
Cited by 253

The DOI matches its Crossref record.

Abstract

The American Society for Testing and Materials (ASTM) mouse bioassay, which quantifies airway irritation from reduction in the respiratory rate, was used to find evidence for the formation of highly irritating substances in reactions of ozone with terpenes (common indoor volatile organic compounds (VOCs)). No-observed-effect-levels (NOELs) and concentration-effect relationships were established for ozone, (+)-alpha-pinene and R-(+)-limonene, isoprene, and some of their major reaction products. Reaction mixtures of excess terpene and ozone considerably below their NOEL concentrations resulted in significant upper airway irritation. The reduction of the respiratory rate was from 30% to about 50%, lowest for the alpha-pinene and highest for the isoprene mixture. Chemical analysis of reaction mixtures by conventional methods showed that readily identified stable products and residual reactants at the concentrations found could not account for the observed reductions of the respiratory rate, assuming additivity of the reaction products. The results suggest that, in addition to known irritants (formaldehyde, acrolein, methacrolein, methyl vinylketone), one or more strong airway irritant(s) of unknown structure(s) were formed. Future indoor air quality (IAQ) guidelines for unsaturated VOCs (e.g., terpenes) and their emission from building products may require the consideration of reactions with oxidants, like ozone. Similarly, effects of ozone-emitting equipment should be re-evaluated.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1034/j.1600-0668.2000.010002082.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
WOLKOFF, P., CLAUSEN, P. A., WILKINS, C. K., & NIELSEN, G. D.
Venue
Indoor Air
Published
2000-06
Volume
10
Issue
2
Pages
82-91
ISSN
0905-6947 (ISSN-L)
OpenAlex
W2164536739
Cited by
253
References
0
FWCI
8.13
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.