An Outbreak of Respiratory Diseases among Workers at a Water-Damaged Building - A Case Report
The DOI matches its Crossref record.
Abstract
We describe a military hospital building with severe, repeated and enduring water and mold damage, and the symptoms and diseases found among 14 persons who were employed at the building. The exposure of the employees was evaluated by measuring the serum immunoglobulin G (IgG)-antibodies against eight spieces of mold and yeast common in Finnish water and mold damaged buildings and by sampling airborne viable microbes within the hospital. The most abundant spieces was Sporobolomyces salmonicolor. All but one of the employees reported some building-related symptoms, the most common being a cough which was reported by nine subjects. Four new cases of asthma, confirmed by S. salmonicolor inhalation provocation tests, one of whom was also found to have alveolitis, were found among the hospital personnel. In addition, seven other workers with newly diagnosed rhinitis reacted positively in nasal S. salmonicolor provocation tests. Skin prick tests by Sporobolomyces were negative among all 14 workers. Exposure of the workers to mold and yeast in the indoor air caused an outbreak of occupational diseases, including asthma, rhinitis and alveolitis. The diseases were not immunoglobulin E (IgE)-mediated but might have been borne by some other, as yet unexplained, mechanism.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Allergic Rhinitis and its Impact on Asthma (ARIA) 2008*
Bousquet, J., Khaltaev, N., Cruz, A. A., Denburg, J., Fokkens, W. J., Togias, A., Zuberbier, T., Baena‐Cagnani, C. E., Canonica, G. W., Van Weel, C., et al. (2008) · Allergy · doi:10.1111/j.1398-9995.2007.01620.x · Cited by 4,729
Allergic Rhinitis and its Impact on Asthma (ARIA) guidelines: 2010 Revision
Brożek, J. L., Bousquet, J., Baena-Cagnani, C. E., Bonini, S., Canonica, G. W., Casale, T. B., van Wijk, R. G., Ohta, K., Zuberbier, T., & Schünemann, H. J. (2010) · Journal of Allergy and Clinical Immunology · doi:10.1016/j.jaci.2010.06.047 · Cited by 1,813
Mendell, M. J., & Heath, G. A. (2005) · Indoor Air · doi:10.1111/j.1600-0668.2004.00320.x · Cited by 1,034
Arendrup, M. C., Boekhout, T., Akova, M., Meis, J. F., Cornely, O. A., & Lortholary, O. (2014) · Clinical Microbiology and Infection · doi:10.1111/1469-0691.12360 · Cited by 529
Indoor Mold, Toxigenic Fungi, and Stachybotrys chartarum: Infectious Disease Perspective
Kuhn, D. M., & Ghannoum, M. A. (2003) · Clinical Microbiology Reviews · doi:10.1128/cmr.16.1.144-172.2003 · Cited by 352
Metadata
- Authors
- SEURI, M., HUSMAN, K., KINNUNEN, H., REIMAN, M., KREUS, R., KURONEN, P., LEHTOMÄKI, K., & PAANANEN, M.
- Venue
- Indoor Air
- Publisher
- Hindawi Limited
- Published
- 2000-09
- Volume
- 10
- Issue
- 3
- Pages
- 138-145
- ISSN
- 0905-6947 (ISSN-L)
- OpenAlex
- W1972733984
- Cited by
- 63
- References
- 0
- FWCI
- 5.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An Outbreak of Respiratory Diseases among Workers at a Water-Damaged Building - A Case Report. https://app.cochat.ai/papers/10.1034/j.1600-0668.2000.010003138.x
- The paper
- SEURI, M., HUSMAN, K., KINNUNEN, H., REIMAN, M., KREUS, R., KURONEN, P., LEHTOMÄKI, K., & PAANANEN, M. (2000). An Outbreak of Respiratory Diseases among Workers at a Water-Damaged Building - A Case Report. Indoor Air. https://doi.org/10.1034/j.1600-0668.2000.010003138.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.