Volatile Organic Compound Concentrations and Emission Rates in New Manufactured and Site-Built Houses: VOC Concentrations and Emission Rates in New Manufactured and Site-Built Houses
Open accessThe DOI matches its Crossref record.
Abstract
Concentrations of 54 volatile organic compounds (VOCs) and ventilation rates were measured in four new manufactured houses over 2-9.5 months following installation and in seven new site-built houses 1-2 months after completion. The houses were in four projects located in hot-humid and mixed-humid climates. They were finished and operational, but unoccupied. Ventilation rates ranged from 0.14-0.78 h-1. Several of the site-built houses had ventilation rates below the ASHRAE recommended value. In both manufactured and site-built houses, the predominant airborne compounds were alpha-pinene, formaldehyde, hexanal, and acetic acid. Formaldehyde concentrations were below or near 50 ppb with a geometric mean value for all houses of 40 ppb. Similarities in the types of VOCs and in VOC concentrations indicated that indoor air quality in the houses was impacted by the same or similar sources. Major identified sources included plywood flooring, latex paint and sheet vinyl flooring. One site-built house was operated at ventilation rates of 0.14 and 0.32 h-1. VOC emission rates calculated at the two conditions agreed within +/- 10% for the most volatile compounds. Generally, the ratios of emission rates at the low and high ventilation rates decreased with decreasing compound volatility. Changes in VOC emission rates in the manufactured houses over 2-9.5 months after installation varied by compound. Only several compounds showed a consistent decrease in emission rate over this period.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Formaldehyde in the Indoor Environment
Salthammer, T., Mentese, S., & Marutzky, R. (2010) · Chemical Reviews · doi:10.1021/cr800399g · Cited by 1,808
Allen, J. G., MacNaughton, P., Satish, U., Santanam, S., Vallarino, J., & Spengler, J. D. (2016) · Environmental Health Perspectives · doi:10.1289/ehp.1510037 · Cited by 977
Sarigiannis, D. A., Karakitsios, S. P., Gotti, A., Liakos, I. L., & Katsoyiannis, A. (2011) · Environment International · doi:10.1016/j.envint.2011.01.005 · Cited by 522
Weschler, C. J. (2006) · Environmental Health Perspectives · doi:10.1289/ehp.9256 · Cited by 481
Mannan, M., & Al-Ghamdi, S. G. (2021) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph18063276 · Cited by 457
Organic compounds in indoor air—their relevance for perceived indoor air quality?
Wolkoff, P., & Nielsen, G. D. (2001) · Atmospheric Environment · doi:10.1016/s1352-2310(01)00244-8 · Cited by 369
Wolkoff, P., Wilkins, C. K., Clausen, P. A., & Nielsen, G. D. (2006) · Indoor Air · doi:10.1111/j.1600-0668.2005.00393.x · Cited by 348
Logue, J. M., McKone, T. E., Sherman, M. H., & Singer, B. C. (2011) · Indoor Air · doi:10.1111/j.1600-0668.2010.00683.x · Cited by 266
Hodgson, A. T., Beal, D., & McIlvaine, J. E. R. (2002) · Indoor Air · doi:10.1034/j.1600-0668.2002.01129.x · Cited by 213
“other aldehydes were within the reported ranges ( Hodgson et al., 2000 ).”
BackgroundMethodSelf-citationQuality of indoor residential air and health
Dales, R., Liu, L., Wheeler, A. J., & Gilbert, N. L. (2008) · Canadian Medical Association Journal · doi:10.1503/cmaj.070359 · Cited by 198
Spatial and temporal variability in VOC levels within a commercial retail building
Eklund, B. M., Burkes, S., Morris, P., & Mosconi, L. (2008) · Indoor Air · doi:10.1111/j.1600-0668.2008.00537.x · Cited by 35
“, 2004) and manufactured houses (Hodgson et al., 2000), as well as for specific types of use, such as telecommunications offices (Shields et al.”
BackgroundGallego, E., Roca, F. J., Perales, J. F., & Guardino, X. (2011) · Sick Building Syndrome · doi:10.1007/978-3-642-17919-8_16 · Cited by 9
Metadata
- Authors
- HODGSON, A. T., RUDD, A. F., BEAL, D., & CHANDRA, S.
- Venue
- Indoor Air
- Publisher
- Hindawi Limited
- Published
- 2000-09
- Volume
- 10
- Issue
- 3
- Pages
- 178-192
- ISSN
- 0905-6947 (ISSN-L)
- OpenAlex
- W1971315969
- Cited by
- 240
- References
- 0
- FWCI
- 6.92
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.