The DOI matches its Crossref record.
Skin color measurements: comparison between three instruments: the Chromameter®, the DermaSpectrometer® and the Mexameter®
Abstract
Background/aims: Two types of skin reflectance instruments are available nowadays for the determination of skin color: a tristumulus colorimeter (Chromameter from Minolta) using the CIE L*a*b* color system and the narrow‐band simple reflectance meters (DermaSpectrometer from Cortex and Mexameter from Courage‐Khazaka) using the erythema/melanin indices. The purpose of this study was to compare the capabilities of the three instruments (sensitivity, repeatability and correlation) in vitro and in vivo. Methods: Comparative color measurements were carried out first in vitro on standardized color charts and subsequently in vivo on different skin areas in human volunteers. Skin color changes induced by various physico‐chemical treatments were also quantitatively evaluated with the three instruments. Results: The in vitro and in vivo repeatabilty as well as the sensitivity of the three instruments are rather good. Erythema and skin blanching could be readily quantified by the increase of the a* parameter and of the erythema indices of the simple reflectance meters. Natural UV tanning and artificial chemical tanning could be measured by the decrease of L* and increase of b* and of the melanin indices. Conclusion: The Chromameter and the two narrow‐band reflectance instruments were able to characterize skin color and to quantify small skin color changes. Moderate to high significant linear correlations could be established between the CIE L*a*b* color parameters and the erythema/melanin indices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Ly, B. C. K., Dyer, E. B., Feig, J. L., Chien, A. L., & Del Bino, S. (2020) · Journal of Investigative Dermatology · doi:10.1016/j.jid.2019.11.003 · Cited by 453
WATTANAKRAI, P., MORNCHAN, R., & EIMPUNTH, S. (2010) · Dermatologic Surgery · doi:10.1111/j.1524-4725.2009.01383.x · Cited by 227
van der Wal, M., Bloemen, M., Verhaegen, P., Tuinebreijer, W., de Vet, H., van Zuijlen, P., & Middelkoop, E. (2013) · Journal of Burn Care & Research · doi:10.1097/bcr.0b013e318264bf7d · Cited by 96
Impact of skin tone on photoacoustic oximetry and tools to minimize bias
Mantri, Y., & Jokerst, J. V. (2022) · Biomedical Optics Express · doi:10.1364/boe.450224 · Cited by 75
Scar Treatment Variations by Skin Type
Visscher, M. O., Bailey, J. K., & Hom, D. B. (2014) · Facial Plastic Surgery Clinics of North America · doi:10.1016/j.fsc.2014.04.010 · Cited by 44
Metadata
- Authors
- Clarys, P., Alewaeters, K., Lambrecht, R., & Barel, A. O.
- Venue
- Skin Research and Technology
- Publisher
- Wiley
- Published
- 2000-11
- Volume
- 6
- Issue
- 4
- Pages
- 230-238
- ISSN
- 0909-752X (ISSN-L)
- 1600-0846
- OpenAlex
- W2004312076
- Cited by
- 381
- References
- 0
- FWCI
- 0.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Skin color measurements: comparison between three instruments: the Chromameter®, the DermaSpectrometer® and the Mexameter®. https://app.cochat.ai/papers/10.1034/j.1600-0846.2000.006004230.x
- The paper
- Clarys, P., Alewaeters, K., Lambrecht, R., & Barel, A. O. (2000). Skin color measurements: comparison between three instruments: the Chromameter®, the DermaSpectrometer® and the Mexameter®. Skin Research and Technology. https://doi.org/10.1034/j.1600-0846.2000.006004230.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.