The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Biodegradable block copolymers as injectable drug-delivery systems
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Alexandridis, P., Holzwarth, J. F., & Hatton, T. A. (1994) · Macromolecules · doi:10.1021/ma00087a009 · Cited by 1,862
Langer, R. (1990) · Science · doi:10.1126/science.2218494 · Cited by 1,778
Moritz, A. R., & Henriques, F. C. (1947) · PubMed · Cited by 1,289
Graft copolymers that exhibit temperature-induced phase transitions over a wide range of pH
Chen, G., & Hoffman, A. S. (1995) · Nature · doi:10.1038/373049a0 · Cited by 1,219
Electrically erodible polymer gel for controlled release of drugs
Kwon, I. C., Bae, Y. H., & Kim, S. W. (1991) · Nature · doi:10.1038/354291a0 · Cited by 655
Self-citationThermo‐sensitive polymers as on‐off switches for drug release
Bae, Y. H., Okano, T., Hsu, R., & Kim, S. W. (1987) · Die Makromolekulare Chemie, Rapid Communications · doi:10.1002/marc.1987.030081002 · Cited by 545
Self-citationSelf-assembly in aqueous block copolymer solutions
Malmsten, M., & Lindman, B. (1992) · Macromolecules · doi:10.1021/ma00046a049 · Cited by 514
Zhu, K. J., Xiangzhou, L., & Shilin, Y. (1990) · Journal of Applied Polymer Science · doi:10.1002/app.1990.070390101 · Cited by 313
Youxin, L., & Kissel, T. (1993) · Journal of Controlled Release · doi:10.1016/0168-3659(93)90155-x · Cited by 166
Ronneberger, B., Kao, W. J., Anderson, J. M., & Kissel, T. (1996) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199601)30:1<31::aid-jbm5>3.0.co;2-s · Cited by 108
Wout, Z. G., Pec, E. A., Maggiore, J. A., et al. (1993) · PubMed · Cited by 96
Cited by
Hydrogels for Tissue Engineering
Lee, K. Y., & Mooney, D. J. (2001) · Chemical Reviews · doi:10.1021/cr000108x · Cited by 5,277
Hydrogels for tissue engineering: scaffold design variables and applications
Drury, J. L., & Mooney, D. J. (2003) · Biomaterials · doi:10.1016/s0142-9612(03)00340-5 · Cited by 5,136
Environment-sensitive hydrogels for drug delivery
Qiu, Y., & Park, K. (2001) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(01)00203-4 · Cited by 3,911
Kamaly, N., Yameen, B., Wu, J., & Farokhzad, O. C. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00346 · Cited by 3,070
Polymeric systems for controlled drug release
Uhrich, K. E., Cannizzaro, S. M., Langer, R. S., & Shakesheff, K. M. (1999) · Chemical Reviews · doi:10.1021/cr940351u · Cited by 2,633
Metadata
- Authors
- Jeong, B., Bae, Y. H., Lee, D. S., & Kim, S. W.
- Venue
- Nature
- Published
- 1997-08-28
- Volume
- 388
- Issue
- 6645
- Pages
- 860-862
- ISSN
- 0028-0836 (ISSN-L)
- 1476-4687
- OpenAlex
- W1800156099
- Cited by
- 1,997
- References
- 11
- FWCI
- 10.10
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.