The DOI matches its Crossref record.
Comparison of the Yield and Miss Rate of Narrow Band Imaging and White Light Endoscopy in Patients Undergoing Screening or Surveillance Colonoscopy: A Meta-Analysis
Abstract
OBJECTIVES: Colonoscopy has an appreciable miss rate for adenomas and colorectal cancer. The goal of advanced endoscopic imaging is to improve lesion detection. Compared with standard definition, high-definition (HD) colonoscopes have the advantage of increased field of visualization and higher resolution; narrow band imaging (NBI) utilizes narrow band filters for enhanced visualization of surface architecture and capillary pattern. The objective of this study was to compare the yield and miss rates of HD-NBI and HD-WLE (white light endoscopy) for the detection of colon polyps using meta-analysis. METHODS: A recursive literature search of randomized controlled trials (RCTs) comparing the yield of HD-NBI and HD-WLE for detection of colon polyps in patients undergoing screening/surveillance colonoscopy. Authors were contacted for missing data. In RCT with tandem colonoscopy (RCT-t), findings from the first-pass examinations were used in the yield analysis and from the tandem pass for the miss rate analysis. Data on the yield of polyps were extracted, pooled, and analyzed using RevMan 4.2.9 software. Odds ratio (OR) and 95% confidence intervals (CIs) for the pooled data for the yield and miss rates of NBI and WLE were calculated. A fixed effect model (FEM) was used for analyses without, and a random effect model (REM) for analyses with heterogeneity. RESULTS: The yield analysis revealed no significant difference between HD-NBI and HD-WLE for the detection of adenomas (six studies; n=2,284; OR: 1.01; CI: 0.74-1.37; REM); patients with polyps (six studies; n=2,275; OR: 1.15; CI: 0.8-1.64; REM); patients with adenomas (four studies; n=2,177; OR: 1.0; CI: 0.83-1.20; FEM); detection of adenomas <10 mm (five studies; n=1,618; OR: 1.32; CI: 0.92-1.88; FEM); flat adenomas (five studies; n=1,675; OR: 1.26; CI: 0.62-2.57; REM); and flat adenomas per patient (five studies; n=2,200; OR: 1.63; CI: 0.71-3.74; REM). The miss rate analysis revealed no difference in polyp miss rate (three studies; n=524; OR: 1.17; CI: 0.8-1.71; FEM) or adenoma miss rate (three studies; n=524; OR: 0.65; CI: 0.4-1.06; FEM) between the two techniques. CONCLUSIONS: Compared with HD-WLE, HD-NBI does not increase the yield of colon polyps, adenomas, or flat adenomas, nor does it decrease the miss rate of colon polyps or adenomas in patients undergoing screening/surveillance colonoscopy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Zhao, S., Wang, S., Pan, P., Xia, T., Chang, X., Yang, X., Guo, L., Meng, Q., Yang, F., Qian, W., et al. (2019) · Gastroenterology · doi:10.1053/j.gastro.2019.01.260 · Cited by 660
Kamiński, M., Hassan, C., Bisschops, R., Pohl, J., Pellisé, M., Dekker, E., Ignjatovic-Wilson, A., Hoffman, A., Longcroft-Wheaton, G., Heresbach, D., et al. (2014) · Endoscopy · doi:10.1055/s-0034-1365348 · Cited by 433
An updated Asia Pacific Consensus Recommendations on colorectal cancer screening
Sung, J. J. Y., Ng, S. C., Chan, F. K. L., Chiu, H. M., Kim, H. S., Matsuda, T., Ng, S. S. M., Lau, J. Y. W., Zheng, S., Adler, S., et al. (2015) · Gut · doi:10.1136/gutjnl-2013-306503 · Cited by 411
Bisschops, R., East, J. E., Hassan, C., Hazewinkel, Y., Kamiński, M. F., Neumann, H., Pellisé, M., Antonelli, G., Bustamante Balen, M., Coron, E., et al. (2019) · Endoscopy · doi:10.1055/a-1031-7657 · Cited by 340
Optimizing the quality of colorectal cancer screening worldwide
Kaminski, M. F., Robertson, D. J., Senore, C., & Rex, D. K. (2020) · Gastroenterology · doi:10.1053/j.gastro.2019.11.026 · Cited by 171
Colonoscopy screening and surveillance guidelines
Saito, Y., Oka, S., Kawamura, T., Shimoda, R., Sekiguchi, M., Tamai, N., Hotta, K., Matsuda, T., Misawa, M., Tanaka, S., et al. (2021) · Digestive Endoscopy · doi:10.1111/den.13972 · Cited by 170
Aniwan, S., Orkoonsawat, P., Viriyautsahakul, V., Angsuwatcharakon, P., Pittayanon, R., Wisedopas, N., Sumdin, S., Ponuthai, Y., Wiangngoen, S., Kullavanijaya, P., et al. (2016) · American Journal of Gastroenterology · doi:10.1038/ajg.2015.440 · Cited by 87
Karsenti, D., Tharsis, G., Perrot, B., Cattan, P., Percie du Sert, A., Venezia, F., Zrihen, E., Gillet, A., Lab, J.-P., Tordjman, G., et al. (2023) · The Lancet Gastroenterology & Hepatology · doi:10.1016/s2468-1253(23)00104-8 · Cited by 62
Metadata
- Authors
- Pasha, S. F., Leighton, J. A., Das, A., Harrison, E. M., Gurudu, S. R., Ramirez, F. C., Fleischer, D. E., & Sharma, V. K.
- Venue
- American Journal of Gastroenterology
- Published
- 2012-03
- Volume
- 107
- Issue
- 3
- Pages
- 363-370
- ISSN
- 0002-9270 (ISSN-L)
- OpenAlex
- W1987693982
- Cited by
- 170
- References
- 0
- FWCI
- 1.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.