The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Diffusion-Weighted Magnetic Resonance Imaging in Ileocolonic Crohn's Disease: Validation of Quantitative Index of Activity
Abstract
OBJECTIVES: Magnetic resonance imaging (MRI) allows accurate assessment of Crohn's disease (CD), but requires gadolinium injection. Diffusion-weighted (DW)-MRI yields comparable performances in small bowel CD. We compared the accuracy of DW-MR enterocolonography (MREC) and the magnetic resonance index of activity (MaRIA), and performed an external validation of the Clermont score in assessing inflammation in CD. METHODS: This was an observational prospective study of a single-center cohort. A total of 130 CD patients underwent consecutively MREC with gadolinium injection and DWI sequences between July 2011 and December 2012. RESULTS: Of the 848 evaluated segments (small bowel=352, colon/rectum=496), 175 (20.6%) were active (small bowel=111, colon/rectum=64) defined as MaRIA ≥7. Using a receiver operating characteristic (ROC) curve, we determined an apparent coefficient of diffusion (ADC) threshold of 1.9 × 10(-3) mm(2)/s that yielded a sensitivity and a specificity in discriminating active from nonactive CD of 96.9% and 98.1%, respectively, for the colon/rectum, and 85.9% and 81.6%, respectively, for the ileum. ADC was better correlated to MaRIA ≥7 than related contrast enhancement obtained with injected sequences (P<0.001). The Clermont score (=1.646 × bowel thickness-1.321 × ADC+5.613 × edema+8.306 × ulceration+5.039) was highly correlated with the MaRIA (rho=0.99) in ileal CD but not in colonic CD (rho <0.80). Interobserver agreement was high with regard to ADC measurement (correlation >0.9, P<0.001, and concordance >0.9, P<0001). CONCLUSIONS: DW-MREC is a reliable tool to assess inflammation in colonic (ADC) and ileal (Clermont score) CD and its use in daily practice would avoid gadolinium injection.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Endoscopic monitoring of Crohn's disease treatment: A prospective, randomized clinical trial
Landi, B., Anh, T. N., Cortot, A., Soule, J. C., Rene, E., Gendre, J. P., Bories, P., See, A., Metman, E. H., Florent, C., et al. (1992) · Gastroenterology · doi:10.1016/0016-5085(92)91725-j · Cited by 261
Cited by
Sturm, A., Maaser, C., Calabrese, E., Annese, V., Fiorino, G., Kucharzik, T., Vavricka, S. R., Verstockt, B., van Rheenen, P., Tolan, D., et al. (2019) · Journal of Crohn's and Colitis · doi:10.1093/ecco-jcc/jjy114 · Cited by 461
Bruining, D. H., Zimmermann, E. M., Loftus, E. V., Sandborn, W. J., Sauer, C. G., Strong, S. A., & Society of Abdominal Radiology Crohn’s Disease-Focused Panel (2018) · Radiology · doi:10.1148/radiol.2018171737 · Cited by 336
Kucharzik, T., Tielbeek, J., Carter, D., Taylor, S. A., Tolan, D., Wilkens, R., Bryant, R. V., Hoeffel, C., De Kock, I., Maaser, C., et al. (2022) · Journal of Crohn's and Colitis · doi:10.1093/ecco-jcc/jjab180 · Cited by 149
Metadata
- Authors
- Hordonneau, C., Buisson, A., Scanzi, J., Goutorbe, F., Pereira, B., Borderon, C., Da Ines, D., Montoriol, P. F., Garcier, J. M., Boyer, L., Bommelaer, G., & Petitcolin, V
- Venue
- American Journal of Gastroenterology
- Published
- 2014-01
- Volume
- 109
- Issue
- 1
- Pages
- 89-98
- ISSN
- 0002-9270 (ISSN-L)
- OpenAlex
- W2063513331
- Cited by
- 219
- References
- 1
- FWCI
- 11.73
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.