Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 279

The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.

What Level of Bowel Prep Quality Requires Early Repeat Colonoscopy: Systematic Review and Meta-Analysis of the Impact of Preparation Quality on Adenoma Detection Rate

Open access
Clark, Brian T, Rustagi, Tarun, Laine, Loren · 2014 · American Journal of Gastroenterology

Abstract

OBJECTIVES: Current guidelines recommend early repeat colonoscopy when bowel preparation quality is inadequate, defined as inability to detect polyps >5 mm, but no data link specific bowel preparation categories or scores to this definition. Nevertheless, most physicians use a shortened screening/surveillance interval in patients with intermediate-quality preparation. We determined whether different levels of bowel preparation quality are associated with differences in adenoma detection rates (ADRs: proportion of colonoscopies with ≥1 adenoma) to help guide decisions regarding early repeat colonoscopy-with primary focus on intermediate-quality preparation. METHODS: MEDLINE and Embase were searched for studies with adenoma or polyp detection rate stratified by bowel preparation quality. Preparation quality definitions were standardized on the basis of Aronchick definitions (excellent/good/fair/poor/insufficient), and primary analyses of ADR trichotomized bowel preparation quality: high quality (excellent/good), intermediate quality (fair), and low quality (poor/insufficient). Dichotomized analyses of adequate (excellent/good/fair) vs. inadequate (poor/insufficient) were also performed. RESULTS: Eleven studies met the inclusion criteria. The primary analysis, ADR with intermediate- vs. high-quality preparation, showed an odds ratio (OR) of 0.94 (0.80-1.10) and absolute risk difference of -1% (-3%, 2%). ADRs were significantly higher with both intermediate-quality and high-quality preparation vs. low-quality preparation: OR=1.39 (1.08-1.79) and 1.41 (1.21-1.64), with absolute risk increases of 5% for both. ADR and advanced ADR were significantly higher with adequate vs. inadequate preparation: OR=1.30 (1.19-1.42) and 1.30 (1.02-1.67). Studies did not report other relevant outcomes such as total adenomas per colonoscopy. CONCLUSIONS: ADR is not significantly different with intermediate-quality vs. high-quality bowel preparation. Our results confirm the need for early repeat colonoscopy with low-quality bowel preparation, but suggest that patients with intermediate/fair preparation quality may be followed up at standard guideline-recommended surveillance intervals without significantly affecting quality as measured by ADR.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/ajg.2014.232

Cites

31 of 31 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 31 references

Cited by

See all 279

Metadata

Authors
Clark, B. T., Rustagi, T., & Laine, L.
Venue
American Journal of Gastroenterology
Published
2014-11
Volume
109
Issue
11
Pages
1714-1723
ISSN
0002-9270 (ISSN-L)
OpenAlex
W2064107750
Cited by
279
References
31
FWCI
2.00
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: What Level of Bowel Prep Quality Requires Early Repeat Colonoscopy: Systematic Review and Meta-Analysis of the Impact of Preparation Quality on Adenoma Detection Rate. https://app.cochat.ai/papers/10.1038/ajg.2014.232
The paper
Clark, B. T., Rustagi, T., & Laine, L. (2014). What Level of Bowel Prep Quality Requires Early Repeat Colonoscopy: Systematic Review and Meta-Analysis of the Impact of Preparation Quality on Adenoma Detection Rate. American Journal of Gastroenterology. https://doi.org/10.1038/ajg.2014.232

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.