CoChat

Multi-Center Colonoscopy Quality Measurement Utilizing Natural Language Processing

Imler, Timothy D, Morea, Justin, Kahi, Charles, Cardwell, Jon, Johnson, Cynthia S, Xu, Huiping, Ahnen, Dennis, Antaki, Fadi, Ashley, Christopher, Baffy, Gyorgy, Cho, Ilseung, Dominitz, Jason, Hou, Jason, Korsten, Mark, Nagar, Anil, Promrat, Kittichai, Robertson, Douglas, Saini, Sameer, Shergill, Amandeep, Smalley, Walter, Imperiale, Thomas F · 2015 · American Journal of Gastroenterology
Cited by 85

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

BACKGROUND: An accurate system for tracking of colonoscopy quality and surveillance intervals could improve the effectiveness and cost-effectiveness of colorectal cancer (CRC) screening and surveillance. The purpose of this study was to create and test such a system across multiple institutions utilizing natural language processing (NLP). METHODS: From 42,569 colonoscopies with pathology records from 13 centers, we randomly sampled 750 paired reports. We trained (n=250) and tested (n=500) an NLP-based program with 19 measurements that encompass colonoscopy quality measures and surveillance interval determination, using blinded, paired, annotated expert manual review as the reference standard. The remaining 41,819 nonannotated documents were processed through the NLP system without manual review to assess performance consistency. The primary outcome was system accuracy across the 19 measures. RESULTS: A total of 176 (23.5%) documents with 252 (1.8%) discrepant content points resulted from paired annotation. Error rate within the 500 test documents was 31.2% for NLP and 25.4% for the paired annotators (P=0.001). At the content point level within the test set, the error rate was 3.5% for NLP and 1.9% for the paired annotators (P=0.04). When eight vaguely worded documents were removed, 125 of 492 (25.4%) were incorrect by NLP and 104 of 492 (21.1%) by the initial annotator (P=0.07). Rates of pathologic findings calculated from NLP were similar to those calculated by annotation for the majority of measurements. Test set accuracy was 99.6% for CRC, 95% for advanced adenoma, 94.6% for nonadvanced adenoma, 99.8% for advanced sessile serrated polyps, 99.2% for nonadvanced sessile serrated polyps, 96.8% for large hyperplastic polyps, and 96.0% for small hyperplastic polyps. Lesion location showed high accuracy (87.0-99.8%). Accuracy for number of adenomas was 92%. CONCLUSIONS: NLP can accurately report adenoma detection rate and the components for determining guideline-adherent colonoscopy surveillance intervals across multiple sites that utilize different methods for reporting colonoscopy findings.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/ajg.2015.51

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 85

Metadata

Authors
Imler, T. D., Morea, J., Kahi, C., Cardwell, J., Johnson, C. S., Xu, H., Ahnen, D., Antaki, F., Ashley, C., Baffy, G., Cho, I., Dominitz, J., Hou, J., Korsten, M., Nagar, A., Promrat, K., Robertson, D., Saini, S., Shergill, A., Smalley, W., & Imperiale, T. F.
Venue
American Journal of Gastroenterology
Published
2015-04
Volume
110
Issue
4
Pages
543-552
ISSN
0002-9270 (ISSN-L)
OpenAlex
W2076073265
Cited by
85
References
3
FWCI
3.25
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Multi-Center Colonoscopy Quality Measurement Utilizing Natural Language Processing. https://app.cochat.ai/papers/10.1038/ajg.2015.51
The paper
Imler, T. D., Morea, J., Kahi, C., Cardwell, J., Johnson, C. S., Xu, H., Ahnen, D., Antaki, F., Ashley, C., Baffy, G., Cho, I., Dominitz, J., Hou, J., Korsten, M., Nagar, A., Promrat, K., Robertson, D., Saini, S., Shergill, A., . . . Imperiale, T. F. (2015). Multi-Center Colonoscopy Quality Measurement Utilizing Natural Language Processing. American Journal of Gastroenterology. https://doi.org/10.1038/ajg.2015.51

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.