The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Quantitative analysis of bone and soft tissue by micro-computed tomography: applications to ex vivo and in vivo studies
Open accessAbstract
Micro-computed tomography (micro-CT) is a high-resolution imaging modality that is capable of analysing bone structure with a voxel size on the order of 10 μm. With the development of in vivo micro-CT, where disease progression and treatment can be monitored in a living animal over a period of time, this modality has become a standard tool for preclinical assessment of bone architecture during disease progression and treatment. For meaningful comparison between micro-CT studies, it is essential that the same parameters for data acquisition and analysis methods be used. This protocol outlines the common procedures that are currently used for sample preparation, scanning, reconstruction and analysis in micro-CT studies. Scan and analysis methods for trabecular and cortical bone are covered for the femur, tibia, vertebra and the full neonate body of small rodents. The analysis procedures using the software provided by ScancoMedical and Bruker are discussed, and the routinely used bone architectural parameters are outlined. This protocol also provides a section dedicated to in vivo scanning and analysis, which covers the topics of anaesthesia, radiation dose and image registration. Because of the expanding research using micro-CT to study other skeletal sites, as well as soft tissues, we also provide a review of current techniques to examine the skull and mandible, adipose tissue, vasculature, tumour severity and cartilage. Lists of recommended further reading and literature references are included to provide the reader with more detail on the methods described.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Basic biomechanical measurements of bone: A tutorial
Turner, C. H., & Burr, D. B. (1993) · Bone · doi:10.1016/8756-3282(93)90081-k · Cited by 1,666 · cited 1×
“If the samples will be used for biomechanical testing or histomorphometric analysis, freezing is the best storage method.(1) For scanning, samples should be cleaned from surrounding soft tissue as much as possible and placed in a sample holder.”
MethodGarofalo, R. S., Orena, S. J., Rafidi, K., Torchia, A. J., Stock, J. L., Hildebrandt, A. L., Coskran, T., Black, S. C., Brees, D. J., Wicks, J. R., et al. (2003) · Journal of Clinical Investigation · doi:10.1172/jci16885 · Cited by 726
Martin-Millan, M., Almeida, M., Ambrogini, E., Han, L., Zhao, H., Weinstein, R. S., Jilka, R. L., O'Brien, C. A., & Manolagas, S. C. (2010) · Molecular Endocrinology · doi:10.1210/me.2009-0354 · Cited by 282 · cited 1×
“The majority of studies on the vertebra examine the entire vertebral body.(11,14,15,19,20) Alternatively, some researchers have specified a volume (for example, 2 mm) centred at the midline,(8) or they have used the growth plate as a landmark.”
Background
Metadata
- Authors
- Campbell, G. M., & Sophocleous, A.
- Venue
- BoneKEy Reports
- Publisher
- Portico
- Published
- 2014-08-20
- Volume
- 3
- Pages
- 564-564
- ISSN
- 2047-6396 (ISSN-L)
- OpenAlex
- W1981981709
- Cited by
- 163
- References
- 3
- FWCI
- 7.52
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Quantitative analysis of bone and soft tissue by micro-computed tomography: applications to ex vivo and in vivo studies. https://app.cochat.ai/papers/10.1038/bonekey.2014.59
- The paper
- Campbell, G. M., & Sophocleous, A. (2014). Quantitative analysis of bone and soft tissue by micro-computed tomography: applications to ex vivo and in vivo studies. BoneKEy Reports. https://doi.org/10.1038/bonekey.2014.59
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.