The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
JC-1: alternative excitation wavelengths facilitate mitochondrial membrane potential cytometry
Open accessAbstract
Mitochondrial membrane potential provides a valuable indicator of cells' health and functional status. Cytometry- and microscopy-based analyses, in combination with fluorescent probes, are widely used to study mitochondrial behavior related to cellular pathways, most notably - apoptosis. The cyanine dye JC-1 (5,5',6,6'-tetrachloro-1,1',3,3'-tetraethylbenzimi- dazolylcarbocyanine iodide) facilitates discrimination of energized and deenergized mitochondria because the normally green fluorescent dye forms red fluorescent aggregates when concentrated in energized mitochondria in response to their higher membrane potential. JC-1 fluorescence is usually excited by the 488 nm laser wavelength common in flow cytometers. In this study, we show that in practice this approach is not optimal for monitoring mitochondrial behavior. Investigation of fluorescence of JC-1 in solution and in cells using spectrofluorimetry, microscopy and flow cytometry reveals that excitation at 405 nm wavelength, now available on standard instruments, produces signals from aggregate fluorescence with considerably less spillover from dye monomer fluorescence than can be obtained using 488 nm excitation. The improved data are more accurate and eliminate the necessity for fluorescence compensation, making the use of the alternative excitation wavelengths beneficial for mitochondria-related biological and biomedial research.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Smiley, S. T., Reers, M., Mottola-Hartshorn, C., Lin, M., Chen, A., Smith, T. W., Steele, G. D., & Chen, L. B. (1991) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.88.9.3671 · Cited by 1,628
Localization of mitochondria in living cells with rhodamine 123.
Johnson, L. V., Walsh, M. L., & Chen, L. B. (1980) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.77.2.990 · Cited by 1,553
Reers, M., Smith, T. W., & Chen, L. B. (1991) · Biochemistry · doi:10.1021/bi00232a015 · Cited by 1,047
Monitoring of relative mitochondrial membrane potential in living cells by fluorescence microscopy.
Johnson, L. V., Walsh, M. L., Bockus, B. J., & Chen, L. B. (1981) · The Journal of cell biology · doi:10.1083/jcb.88.3.526 · Cited by 913
Petit, P. X., Lecoeur, H., Zorn, E., Dauguet, C., Mignotte, B., & Gougeon, M. L. (1995) · The Journal of cell biology · doi:10.1083/jcb.130.1.157 · Cited by 592
Cell Growth and Size Homeostasis in Proliferating Animal Cells
Tzur, A., Kafri, R., LeBleu, V. S., Lahav, G., & Kirschner, M. W. (2009) · Science · doi:10.1126/science.1174294 · Cited by 402
Self-citationCossarizza, A., Franceschi, C., Monti, D., Salvioli, S., Bellesia, E., Rivabene, R., Biondo, L., Rainaldi, G., Tinari, A., & Malorni, W. (1995) · Experimental Cell Research · doi:10.1006/excr.1995.1311 · Cited by 273
Quantitative assay by flow cytometry of the mitochondrial membrane potential in intact cells
Rottenberg, H., & Wu, S. (1998) · Biochimica et Biophysica Acta (BBA) - Molecular Cell Research · doi:10.1016/s0167-4889(98)00088-3 · Cited by 272
Increased mitochondrial uptake of rhodamine 123 during lymphocyte stimulation.
Darzynkiewicz, Z., Staiano-Coico, L., & Melamed, M. R. (1981) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.78.4.2383 · Cited by 210
Optimizing Optical Flow Cytometry for Cell Volume-Based Sorting and Analysis
Tzur, A., Moore, J. K., Jorgensen, P., Shapiro, H. M., & Kirschner, M. W. (2011) · PLoS ONE · doi:10.1371/journal.pone.0016053 · Cited by 184
Self-citation
Cited by
Tai, H., Wang, Z., Gong, H., Han, X., Zhou, J., Wang, X., Wei, X., Ding, Y., Huang, N., Qin, J., et al. (2017) · Autophagy · doi:10.1080/15548627.2016.1247143 · Cited by 334
Dubey, D., Chopra, D., Singh, J., Srivastav, A. K., Kumari, S., Verma, A., & Ray, R. S. (2017) · Food and Chemical Toxicology · doi:10.1016/j.fct.2017.07.056 · Cited by 53
She, X., Khamooshi, K., Gao, Y., Shen, Y., Lv, Y., Calderone, R., Fonzi, W., Liu, W., & Li, D. (2015) · Cellular Microbiology · doi:10.1111/cmi.12438 · Cited by 51
“The fluorescent dye JC-1 (5,5′,6,6′-tetrachloro-1,1′,3,3′tetraethylbenzimidazolocarbo-cyanine iodide) (Gallagher, 2010; Perelman et al., 2012) was obtained from Invitrogen, Inc.”
MethodCaicedo, A., Zambrano, K., Sanon, S., Luis Vélez, J., Montalvo, M., Jara, F., Moscoso, S. A., Vélez, P., Maldonado, A., & Velarde, G. (2021) · Mitochondrion · doi:10.1016/j.mito.2021.02.014 · Cited by 48
Gupta, P. K., Pappuru, S., Gupta, S., Patra, B., Chakraborty, D., & Verma, R. S. (2019) · Materials Science and Engineering: C · doi:10.1016/j.msec.2019.03.041 · Cited by 44
Metadata
- Authors
- Perelman, A., Wachtel, C., Cohen, M., Haupt, S., Shapiro, H., & Tzur, A.
- Venue
- Cell Death & Disease
- Published
- 2012-11-22
- Volume
- 3
- Issue
- 11
- Pages
- e430-e430
- ISSN
- 2041-4889 (ISSN-L)
- OpenAlex
- W2071007484
- Cited by
- 699
- References
- 12
- FWCI
- 5.11
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: JC-1: alternative excitation wavelengths facilitate mitochondrial membrane potential cytometry. https://app.cochat.ai/papers/10.1038/cddis.2012.171
- The paper
- Perelman, A., Wachtel, C., Cohen, M., Haupt, S., Shapiro, H., & Tzur, A. (2012). JC-1: alternative excitation wavelengths facilitate mitochondrial membrane potential cytometry. Cell Death & Disease. https://doi.org/10.1038/cddis.2012.171
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.