CoChat

Stereochemical aspects of warfarin drug interactions: Use of a combined pharmacokinetic-pharmacodynamic model

Chan, Eli, Mclachlan, Andrew, O'reilly, Robert, Rowland, Malcolm · 1994 · Clinical Pharmacology & Therapeutics
Cited by 93

The DOI matches its Crossref record.

Abstract

OBJECTIVE: To apply a combined pharmacokinetic-pharmacodynamic model to data from warfarin drug interaction studies. METHODS: The pharmacokinetic model for warfarin enantiomers combined a common first-order absorption process with individual clearance and volume of distribution values and is based on unbound drug. The complete pharmacodynamic model comprised two components: that involving inhibition of prothrombin complex activity (PCA) synthesis described by a sigmoid maximum effect (Emax) model and that relating temporal changes in PCA to synthesis and degradation. The combined model was applied to prothrombin time and plasma concentration-time data obtained after oral administration of single doses of racemic warfarin to healthy subjects either alone or during multiple dosing with the metabolic enzyme inhibitor phenylbutazone or the inducer secobarbital. RESULTS: The five parameters associated with the complete pharmacodynamic model were kd (0.054 +/- 0.014 hr-1), the degradation rate constant of PCA; Cu50,S (0.0026 +/- 0.0015 mg.L-1) and Cu50,R (3.45 +/- 4.20 mg.L-1), the unbound concentrations of (S)- and (R)-warfarin required to produce a 50% reduction in PCA synthesis if administered individually; gamma (0.90 +/- 0.23), the slope parameter in the sigmoid Emax model; and td (8.2 +/- 0.3 hours), the observed delay in the onset of warfarin anticoagulant response. CONCLUSIONS: These findings qualitatively confirm the known potency difference between warfarin enantiomers. Furthermore, although phenylbutazone and secobarbital altered the pharmacokinetics of warfarin, these compounds do not appear to influence its pharmacodynamics. Simulation studies indicate that, after racemate administration, the continual presence of the more potent (S)-enantiomer precludes accurate assessment of Cu50,R. Analysis indicates that use of racemic (rather than enantiomer) warfarin concentration data in drug interaction studies may lead to misinterpretation of pharmacodynamic data.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/clpt.1994.139

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 93

Metadata

Authors
Chan, E., Mclachlan, A., O'reilly, R., & Rowland, M.
Venue
Clinical Pharmacology & Therapeutics
Publisher
Wiley
Published
1994-09
Volume
56
Issue
3
Pages
286-294
ISSN
  • 0009-9236 (ISSN-L)
  • 1532-6535
OpenAlex
W1965277351
Cited by
93
References
0
FWCI
1.79
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Stereochemical aspects of warfarin drug interactions: Use of a combined pharmacokinetic-pharmacodynamic model. https://app.cochat.ai/papers/10.1038/clpt.1994.139
The paper
Chan, E., Mclachlan, A., O'reilly, R., & Rowland, M. (1994). Stereochemical aspects of warfarin drug interactions: Use of a combined pharmacokinetic-pharmacodynamic model. Clinical Pharmacology & Therapeutics. https://doi.org/10.1038/clpt.1994.139

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.