The Reference Image Database to Evaluate Response to Therapy in Lung Cancer (RIDER) Project: A Resource for the Development of Change-Analysis Software
Open accessThe DOI matches its Crossref record.
Abstract
Critical to the clinical evaluation of effective novel therapies for lung cancer is the early and accurate determination of tumor response, which requires an understanding of the sources of uncertainty in tumor measurement and subsequent attempts to minimize their effects on the assessment of the therapeutic agent. The Reference Image Database to Evaluate Response (RIDER) project seeks to develop a consensus approach to the optimization and benchmarking of software tools for the assessment of tumor response to therapy and to provide a publicly available database of serial images acquired during lung cancer drug and radiation therapy trials. Images of phantoms and patient images acquired under situations in which tumor size or biology is known to be unchanged also will be provided. The RIDER project will create standardized methods for benchmarking software tools to reduce sources of uncertainty in vital clinical assessments such as whether a specific tumor is responding to therapy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Armato, S. G., McLennan, G., Bidaut, L., McNitt‐Gray, M. F., Meyer, C. R., Reeves, A. P., Zhao, B., Aberle, D. R., Henschke, C. I., Hoffman, E. A., et al. (2011) · Medical Physics · doi:10.1118/1.3528204 · Cited by 2,887
Self-citationRadiomics: the process and the challenges
Kumar, V., Gu, Y., Basu, S., Berglund, A., Eschrich, S. A., Schabath, M. B., Forster, K., Aerts, H. J. W. L., Dekker, A., Fenstermacher, D., et al. (2012) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2012.06.010 · Cited by 2,258
“Currently available clinical image data which may be used for radiomics study includes the Lung Image Database Consortium, the Reference Image Database to Evaluate Response to therapy in lung cancer and others [27,28].”
MethodLimkin, E. J., Sun, R., Dercle, L., Zacharaki, E. I., Robert, C., Reuzé, S., Schernberg, A., Paragios, N., Deutsch, E., & Ferté, C. (2017) · Annals of Oncology · doi:10.1093/annonc/mdx034 · Cited by 757
Validation of A Method to Compensate Multicenter Effects Affecting CT Radiomics
Orlhac, F., Frouin, F., Nioche, C., Ayache, N., & Buvat, I. (2019) · Radiology · doi:10.1148/radiol.2019182023 · Cited by 411
Reproducibility and Prognosis of Quantitative Features Extracted from CT Images
Balagurunathan, Y., Gu, Y., Wang, H., Kumar, V., Grove, O., Hawkins, S., Kim, J., Goldgof, D. B., Hall, L. O., Gatenby, R. A., et al. (2014) · Translational Oncology · doi:10.1593/tlo.13844 · Cited by 306
Khorrami, M., Prasanna, P., Gupta, A., Patil, P., Velu, P. D., Thawani, R., Corredor, G., Alilou, M., Bera, K., Fu, P., et al. (2020) · Cancer Immunology Research · doi:10.1158/2326-6066.cir-19-0476 · Cited by 297
“Previous studies have also used radiomics to predict response to ICIs (15, 24, 62, 63).”
MethodInfluentialMasood, A., Sheng, B., Li, P., Hou, X., Wei, X., Qin, J., & Feng, D. (2018) · Journal of Biomedical Informatics · doi:10.1016/j.jbi.2018.01.005 · Cited by 292
“The dataset was from 6 di ff erent sources LIDC-IDRI database [32], RIDER [33], LungCT-Diagnosis [34], and LUng Nodule Analysis (LUNA) 2016 Dataset [35].”
MethodReview and current status of SPECT scatter correction
Hutton, B. F., Buvat, I., & Beekman, F. J. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/14/r01 · Cited by 217
“…(Reilhac et al 2006, Castiglioni et al 2005) and recent work to establish cross-site comparability either for establishing common normal ranges (Dickson et al 2010) or demonstrating site compliance with standards for multi-centre clinical trials (Armato et al 2008, Meyer et al 2009, Frank 2008).”
BackgroundTest–Retest Data for Radiomics Feature Stability Analysis: Generalizable or Study-Specific?
van Timmeren, J. E., Leijenaar, R. T. H., van Elmpt, W., Wang, J., Zhang, Z., Dekker, A., & Lambin, P. (2016) · Tomography · doi:10.18383/j.tom.2016.00208 · Cited by 191
Yamashita, R., Perrin, T., Chakraborty, J., Chou, J. F., Horvat, N., Koszalka, M. A., Midya, A., Gonen, M., Allen, P., Jarnagin, W. R., et al. (2020) · European Radiology · doi:10.1007/s00330-019-06381-8 · Cited by 76
“lower number of reproducible pancreas features in our study compared with prior lung radiomics investigations, including the Balagurunathan study with the RIDER dataset [38], may be due to our inclusion of CECT scans separated by 2 weeks rather than using a coffee-break–type design as used in these studies.”
BackgroundResult
Metadata
- Authors
- Armato, S., Meyer, C., McNitt-Gray, M., McLennan, G., Reeves, A., Croft, B., & Clarke, L.
- Venue
- Clinical Pharmacology & Therapeutics
- Publisher
- Wiley
- Published
- 2008-08-27
- Volume
- 84
- Issue
- 4
- Pages
- 448-456
- ISSN
- 0009-9236 (ISSN-L)
- 1532-6535
- OpenAlex
- W2036382630
- Cited by
- 92
- References
- 0
- FWCI
- 3.82
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.