The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Validation of A Method to Compensate Multicenter Effects Affecting CT Radiomics
Open accessAbstract
Background Radiomics extracts features from medical images more precisely and more accurately than visual assessment. However, radiomics features are affected by CT scanner parameters such as reconstruction kernel or section thickness, thus obscuring underlying biologically important texture features. Purpose To investigate whether a compensation method could correct for the variations of radiomic feature values caused by using different CT protocols. Materials and Methods Phantom data involving 10 texture patterns and 74 patients in cohorts 1 (19 men; 42 patients; mean age, 60.4 years; September-October 2013) and 2 (16 men; 32 patients; mean age, 62.1 years; January-September 2007) scanned by using different CT protocols were retrospectively included. For any radiomic feature, the compensation approach identified a protocol-specific transformation to express all data in a common space that were devoid of protocol effects. The differences in statistical distributions between protocols were assessed by using Friedman tests before and after compensation. Principal component analyses were performed on the phantom data to evaluate the ability to distinguish between texture patterns after compensation. Results In the phantom data, the statistical distributions of features were different between protocols for all radiomic features and texture patterns (P < .05). After compensation, the protocol effect was no longer detectable (P > .05). Principal component analysis demonstrated that each texture pattern was no longer displayed as different clusters corresponding to different imaging protocols, unlike what was observed before compensation. The correction for scanner effect was confirmed in patient data with 100% (10 of 10 features for cohort 1) and 98% (87 of 89 features for cohort 2) of P values less than .05 before compensation, compared with 30% (three of 10) and 15% (13 of 89) after compensation. Conclusion Image compensation successfully realigned feature distributions computed from different CT imaging protocols and should facilitate multicenter radiomic studies. © RSNA, 2019 Online supplemental material is available for this article. See also the editorial by Steiger and Sood in this issue.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Controlling the False Discovery Rate: A Practical and Powerful Approach to Multiple Testing
Benjamini, Y., & Hochberg, Y. (1995) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1995.tb02031.x · Cited by 109,482
Adjusting batch effects in microarray expression data using empirical Bayes methods
Johnson, W. E., Li, C., & Rabinovic, A. (2007) · Biostatistics · doi:10.1093/biostatistics/kxj037 · Cited by 8,658
Radiomics: Images Are More than Pictures, They Are Data
Gillies, R. J., Kinahan, P. E., & Hricak, H. (2016) · Radiology · doi:10.1148/radiol.2015151169 · Cited by 8,421
Decoding tumour phenotype by noninvasive imaging using a quantitative radiomics approach
Aerts, H. J. W. L., Velazquez, E. R., Leijenaar, R. T. H., Parmar, C., Grossmann, P., Carvalho, S., Bussink, J., Monshouwer, R., Haibe-Kains, B., Rietveld, D., et al. (2014) · Nature Communications · doi:10.1038/ncomms5006 · Cited by 5,132
Harmonization of cortical thickness measurements across scanners and sites
Fortin, J.-P., Cullen, N., Sheline, Y. I., Taylor, W. D., Aselcioglu, I., Cook, P. A., Adams, P., Cooper, C., Fava, M., McGrath, P. J., et al. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2017.11.024 · Cited by 1,580
Nioche, C., Orlhac, F., Boughdad, S., Reuzé, S., Goya-Outi, J., Robert, C., Pellot-Barakat, C., Soussan, M., Frouin, F., & Buvat, I. (2018) · Cancer Research · doi:10.1158/0008-5472.can-18-0125 · Cited by 1,167
Self-citationImaging biomarker roadmap for cancer studies
O'Connor, J. P. B., Aboagye, E. O., Adams, J. E., Aerts, H. J. W. L., Barrington, S. F., Beer, A. J., Boellaard, R., Bohndiek, S. E., Brady, M., Brown, G., et al. (2017) · Nature Reviews Clinical Oncology · doi:10.1038/nrclinonc.2016.162 · Cited by 1,091
CT Texture Analysis: Definitions, Applications, Biologic Correlates, and Challenges
Lubner, M. G., Smith, A. D., Sandrasegaran, K., Sahani, D. V., & Pickhardt, P. J. (2017) · RadioGraphics · doi:10.1148/rg.2017170056 · Cited by 773
Measuring Computed Tomography Scanner Variability of Radiomics Features
Mackin, D., Fave, X., Zhang, L., Fried, D., Yang, J., Taylor, B., Rodriguez-Rivera, E., Dodge, C., Jones, A. K., & Court, L. (2015) · Investigative Radiology · doi:10.1097/rli.0000000000000180 · Cited by 651
Berenguer, R., Pastor-Juan, M. D. R., Canales-Vázquez, J., Castro-García, M., Villas, M. V., Mansilla Legorburo, F., & Sabater, S. (2018) · Radiology · doi:10.1148/radiol.2018172361 · Cited by 622
Cited by
Zwanenburg, A., Vallières, M., Abdalah, M. A., Aerts, H. J. W. L., Andrearczyk, V., Apte, A., Ashrafinia, S., Bakas, S., Beukinga, R. J., Boellaard, R., et al. (2020) · Radiology · doi:10.1148/radiol.2020191145 · Cited by 4,177
Self-citationRadiomics in medical imaging—“how-to” guide and critical reflection
van Timmeren, J. E., Cester, D., Tanadini-Lang, S., Alkadhi, H., & Baessler, B. (2020) · Insights into Imaging · doi:10.1186/s13244-020-00887-2 · Cited by 1,316
Predicting cancer outcomes with radiomics and artificial intelligence in radiology
Bera, K., Braman, N., Gupta, A., Velcheti, V., & Madabhushi, A. (2022) · Nature Reviews Clinical Oncology · doi:10.1038/s41571-021-00560-7 · Cited by 819
Park, J. E., Park, S. Y., Kim, H. J., & Kim, H. S. (2019) · Korean Journal of Radiology · doi:10.3348/kjr.2018.0070 · Cited by 388
A Guide to ComBat Harmonization of Imaging Biomarkers in Multicenter Studies
Orlhac, F., Eertink, J. J., Cottereau, A.-S., Zijlstra, J. M., Thieblemont, C., Meignan, M., Boellaard, R., & Buvat, I. (2022) · Journal of Nuclear Medicine · doi:10.2967/jnumed.121.262464 · Cited by 348
Self-citation
Metadata
- Authors
- Orlhac, F., Frouin, F., Nioche, C., Ayache, N., & Buvat, I.
- Venue
- Radiology
- Published
- 2019-04
- Volume
- 291
- Issue
- 1
- Pages
- 53-59
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2913754119
- Cited by
- 411
- References
- 25
- FWCI
- 32.55
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Validation of A Method to Compensate Multicenter Effects Affecting CT Radiomics. https://app.cochat.ai/papers/10.1148/radiol.2019182023
- The paper
- Orlhac, F., Frouin, F., Nioche, C., Ayache, N., & Buvat, I. (2019). Validation of A Method to Compensate Multicenter Effects Affecting CT Radiomics. Radiology. https://doi.org/10.1148/radiol.2019182023
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.