Processive kinesins require loose mechanical coupling for efficient collective motility
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
Processive motor proteins are stochastic steppers that perform actual mechanical steps for only a minor fraction of the time they are bound to the filament track. Motors usually work in teams and therefore the question arises whether the stochasticity of stepping can cause mutual interference when motors are mechanically coupled. We used biocompatible surfaces to immobilize processive kinesin‐1 motors at controlled surface densities in a mechanically well‐defined way. This helped us to study quantitatively how mechanical coupling between motors affects the efficiency of collective microtubule transport. We found that kinesin‐1 constructs that lack most of the non‐motor sequence slow each other down when collectively transporting a microtubule, depending on the number of interacting motors. This negative interference observed for a motor ensemble can be explained quantitatively by a mathematical model using the known physical properties of individual molecules of kinesin‐1. The non‐motor extension of kinesin‐1 reduces this mutual interference, indicating that loose mechanical coupling between motors is required for efficient transport by ensembles of processive motors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Direct observation of kinesin stepping by optical trapping interferometry
Svoboda, K., Schmidt, C. F., Schnapp, B. J., & Block, S. M. (1993) · Nature · doi:10.1038/365721a0 · Cited by 1,910 · cited 1×
“Single-molecule experiments have shown that motors are stochastic steppers (Svoboda et al, 1993; Mehta et al, 1999; Reck-Peterson et al, 2006).”
BackgroundForce and velocity measured for single kinesin molecules
Svoboda, K., & Block, S. M. (1994) · Cell · doi:10.1016/0092-8674(94)90060-4 · Cited by 909 · cited 2×
“It is known that individual kinesins slow down when experiencing a hindering load (Svoboda & Block, 1994; Carter & Cross, 2005).”
BackgroundMovement of microtubules by single kinesin molecules
Howard, J., Hudspeth, A. J., & Vale, R. D. (1989) · Nature · doi:10.1038/342154a0 · Cited by 885 · cited 2×
“…previous observations by showing that the velocity of collective microtubule transport did not depend on the density of full-length kinesin-1 within the range of previously reported densities (up to around 1,000 motors mm 2; Fig 2F, data shown in blue; Howard et al, 1989; Hancock & Howard, 1998).”
BackgroundCarter, N. J., & Cross, R. A. (2005) · Nature · doi:10.1038/nature03528 · Cited by 743 · cited 4×
“It is known that individual kinesins slow down when experiencing a hindering load (Svoboda & Block, 1994; Carter & Cross, 2005).”
BackgroundInfluentialDirect observation of single kinesin molecules moving along microtubules
Vale, R. D., Funatsu, T., Pierce, D. W., Romberg, L., Harada, Y., & Yanagida, T. (1996) · Nature · doi:10.1038/380451a0 · Cited by 711 · cited 1×
“By contrast, monomeric kinesin Kin340GFP did not show processive runs (supplementary Movie 1 online; Fig 1C), as expected (Vale et al, 1996).”
BackgroundForce production by single kinesin motors
Schnitzer, M. J., Visscher, K., & Block, S. M. (2000) · Nature Cell Biology · doi:10.1038/35036345 · Cited by 572
Reconstitution of a microtubule plus-end tracking system in vitro
Bieling, P., Laan, L., Schek, H., Munteanu, E. L., Sandblad, L., Dogterom, M., Brunner, D., & Surrey, T. (2007) · Nature · doi:10.1038/nature06386 · Cited by 475 · cited 3×
“In flow chambers with biotin-PEG instead of Tris-NTA-PEG functionalized glass (Bieling et al, 2007), biotinylated, Alexa568-labelled and pactitaxel-stabilized microtubules were allowed to adhere to the surface through NeutrAvidin (Invitrogen; Karlsruhe, Germany) for 5 min and the remaining free…”
MethodSelf-citationHow kinesin waits between steps
Mori, T., Vale, R. D., & Tomishige, M. (2007) · Nature · doi:10.1038/nature06346 · Cited by 171 · cited 1×
“The duration of the actual mechanical step is several orders of magnitude shorter than the dwell time between individual steps (Carter & Cross, 2005) during which the motor is firmly attached to the microtubule (Mori et al, 2007).”
Background
Cited by
Active matter at the interface between materials science and cell biology
Needleman, D., & Dogic, Z. (2017) · Nature Reviews Materials · doi:10.1038/natrevmats.2017.48 · Cited by 649
A minimal midzone protein module controls formation and length of antiparallel microtubule overlaps
Bieling, P., Telley, I. A., & Surrey, T. (2010) · Cell · doi:10.1016/j.cell.2010.06.033 · Cited by 326
Self-citationKinesin Assembly and Movement in Cells
Verhey, K. J., Kaul, N., & Soppina, V. (2011) · Annual Review of Biophysics · doi:10.1146/annurev-biophys-042910-155310 · Cited by 231
Microtubule organization by the antagonistic mitotic motors kinesin-5 and kinesin-14
Hentrich, C., & Surrey, T. (2010) · The Journal of Cell Biology · doi:10.1083/jcb.200910125 · Cited by 167
Self-citation
Metadata
- Authors
- Bieling, P., Telley, I. A., Piehler, J., & Surrey, T.
- Venue
- EMBO reports
- Published
- 2008-09-19
- Volume
- 9
- Issue
- 11
- Pages
- 1121-1127
- ISSN
- 1469-221X (ISSN-L)
- 1469-3178
- OpenAlex
- W2020007964
- Cited by
- 111
- References
- 8
- FWCI
- 3.55
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Processive kinesins require loose mechanical coupling for efficient collective motility. https://app.cochat.ai/papers/10.1038/embor.2008.169
- The paper
- Bieling, P., Telley, I. A., Piehler, J., & Surrey, T. (2008). Processive kinesins require loose mechanical coupling for efficient collective motility. EMBO reports. https://doi.org/10.1038/embor.2008.169
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.