Error Analysis of a Quantitative Cerebral Blood Flow Measurement Using H215O Autoradiography and Positron Emission Tomography, with Respect to the Dispersion of the Input Function

Open access
Iida, Hidehiro, Kanno, Iwao, Miura, Shuichi, Murakami, Matsutaro, Takahashi, Kazuhiro, Uemura, Kazuo·1986·Journal of Cerebral Blood Flow & Metabolism

Abstract

The effect of the inaccuracy of the input function on CBF measured by the H 152 O autoradiographic method was investigated. In H 152 O autoradiography the measured input function usually includes a larger dispersion than the true input function, as well as the absolute time axis having been already lost. The time constant of the external dispersion that occurred in our continuous sampling system was evaluated as 10–12 s when the dispersion function was approximated by a monoexponential function. The internal dispersion occurring in arterial lines in a human body was evaluated as 4–6 s. Such dispersion, indispensable in a patient study, was found to produce large errors in calculating CBF, e.g., 5(10) s of the dispersion caused + 15(33) and + 10(20)% systematic overestimations for the 40- and 60-s accumulation time, respectively. An analytical correction employing an inverse Laplace transform was applied to clinical CBF studies, and the results were compared with those from the C 15 O 2 steady-state inhalation method. Correction by 10 s in time constant, corresponding to the external dispersion, reduced the overestimation significantly from 70–100% to ∼20%. Further correction by 5 s, corresponding to the internal dispersion, resulted in a negligible difference (less than a few percent) from the steady-state method.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/jcbfm.1986.99

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 373

Metadata

Authors
Iida, H., Kanno, I., Miura, S., Murakami, M., Takahashi, K., & Uemura, K.
Venue
Journal of Cerebral Blood Flow & Metabolism
Published
1986-10
Volume
6
Issue
5
Pages
536-545
ISSN
  • 0271-678X (ISSN-L)
  • 1559-7016
OpenAlex
W1969451158
Cited by
373
References
0
FWCI
8.00
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Error Analysis of a Quantitative Cerebral Blood Flow Measurement Using H215O Autoradiography and Positron Emission Tomography, with Respect to the Dispersion of the Input Function. https://app.cochat.ai/papers/10.1038/jcbfm.1986.99
The paper
Iida, H., Kanno, I., Miura, S., Murakami, M., Takahashi, K., & Uemura, K. (1986). Error Analysis of a Quantitative Cerebral Blood Flow Measurement Using H215O Autoradiography and Positron Emission Tomography, with Respect to the Dispersion of the Input Function. Journal of Cerebral Blood Flow & Metabolism. https://doi.org/10.1038/jcbfm.1986.99

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.