The DOI matches its Crossref record.
Error Analysis of a Quantitative Cerebral Blood Flow Measurement Using H215O Autoradiography and Positron Emission Tomography, with Respect to the Dispersion of the Input Function
Open accessAbstract
The effect of the inaccuracy of the input function on CBF measured by the H 152 O autoradiographic method was investigated. In H 152 O autoradiography the measured input function usually includes a larger dispersion than the true input function, as well as the absolute time axis having been already lost. The time constant of the external dispersion that occurred in our continuous sampling system was evaluated as 10–12 s when the dispersion function was approximated by a monoexponential function. The internal dispersion occurring in arterial lines in a human body was evaluated as 4–6 s. Such dispersion, indispensable in a patient study, was found to produce large errors in calculating CBF, e.g., 5(10) s of the dispersion caused + 15(33) and + 10(20)% systematic overestimations for the 40- and 60-s accumulation time, respectively. An analytical correction employing an inverse Laplace transform was applied to clinical CBF studies, and the results were compared with those from the C 15 O 2 steady-state inhalation method. Correction by 10 s in time constant, corresponding to the external dispersion, reduced the overestimation significantly from 70–100% to ∼20%. Further correction by 5 s, corresponding to the internal dispersion, resulted in a negligible difference (less than a few percent) from the steady-state method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Spectral Analysis of Dynamic PET Studies
Cunningham, V. J., & Jones, T. (1993) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.1993.5 · Cited by 498
Kaisti, K. K., Långsjö, J. W., Aalto, S., Oikonen, V., Sipilä, H., Teräs, M., Hinkka, S., Metsähonkala, L., & Scheinin, H. (2003) · Anesthesiology · doi:10.1097/00000542-200309000-00015 · Cited by 428
Update on Bispectral Index monitoring
Johansen, J. W. (2006) · Best Practice & Research Clinical Anaesthesiology · doi:10.1016/j.bpa.2005.08.004 · Cited by 313
The National High Blood Pressure Education Program: Thirty Years and Counting
Jones, D. W., & Hall, J. E. (2002) · Hypertension · doi:10.1161/01.hyp.0000018303.61360.28 · Cited by 279
Romero, L. M., & Remage-Healey, L. (2000) · General and Comparative Endocrinology · doi:10.1006/gcen.2000.7491 · Cited by 259
Metadata
- Authors
- Iida, H., Kanno, I., Miura, S., Murakami, M., Takahashi, K., & Uemura, K.
- Venue
- Journal of Cerebral Blood Flow & Metabolism
- Publisher
- SAGE Publications
- Published
- 1986-10
- Volume
- 6
- Issue
- 5
- Pages
- 536-545
- ISSN
- 0271-678X (ISSN-L)
- 1559-7016
- OpenAlex
- W1969451158
- Cited by
- 373
- References
- 0
- FWCI
- 8.00
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Error Analysis of a Quantitative Cerebral Blood Flow Measurement Using H215O Autoradiography and Positron Emission Tomography, with Respect to the Dispersion of the Input Function. https://app.cochat.ai/papers/10.1038/jcbfm.1986.99
- The paper
- Iida, H., Kanno, I., Miura, S., Murakami, M., Takahashi, K., & Uemura, K. (1986). Error Analysis of a Quantitative Cerebral Blood Flow Measurement Using H215O Autoradiography and Positron Emission Tomography, with Respect to the Dispersion of the Input Function. Journal of Cerebral Blood Flow & Metabolism. https://doi.org/10.1038/jcbfm.1986.99
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.