Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 498

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Spectral Analysis of Dynamic PET Studies

Cunningham, Vincent J., Jones, Terry·1993·Journal of Cerebral Blood Flow & Metabolism

Abstract

We describe a new technique for the analysis of dynamic positron emission tomography (PET) studies in humans, where data consist of the time courses of label in tissue regions of interest and in arterial blood, following the administration of radiolabeled tracers. The technique produces a simple spectrum of the kinetic components which relate the tissue's response to the blood activity curve. From this summary of the kinetic components, the tissue's unit impulse response can be derived. The convolution of the arterial input function with the derived unit impulse response function gives the curve of best fit to the observed tissue data. The analysis makes no a priori assumptions regarding the number of compartments or components required to describe the time course of label in the tissue. Rather, it is based on a general linear model, presented here in a formulation compatible with its solution using standard computer algorithms. Its application is illustrated with reference to cerebral blood flow, glucose utilization, and ligand binding. The interpretation of the spectra, and of the tissue unit impulse response functions, are discussed in terms of vascular components, unidirectional clearance of tracer by the tissue, and reversible and irreversible phenomena. The significance of the number of components which can be identified within a given datum set is also discussed. The technique facilitates the interpretation of dynamic PET data and simplifies comparisons between regions and between subjects.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/jcbfm.1993.5

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

See all 498

Metadata

Authors
Cunningham, V. J., & Jones, T.
Venue
Journal of Cerebral Blood Flow & Metabolism
Published
1993-01
Volume
13
Issue
1
Pages
15-23
ISSN
  • 0271-678X (ISSN-L)
  • 1559-7016
OpenAlex
W2035837210
Cited by
498
References
8
FWCI
6.05
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Spectral Analysis of Dynamic PET Studies. https://app.cochat.ai/papers/10.1038/jcbfm.1993.5
The paper
Cunningham, V. J., & Jones, T. (1993). Spectral Analysis of Dynamic PET Studies. Journal of Cerebral Blood Flow & Metabolism. https://doi.org/10.1038/jcbfm.1993.5

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.