Quantitative Comparison of Measurements of Cerebral Glucose Metabolic Rate Made with Two Positron Cameras
The DOI matches its Crossref record.
Abstract
The rapid progress in PET technology has created the dilemma of how to compare data from old and new tomographs. We examined cerebral metabolic data from two scanners, with different spatial resolutions and methods of attenuation correction, to see if metabolic values from the lower-resolution tomograph (ECAT II) could be adjusted to make them comparable to data from the higher-resolution scanner (Scanditronix PC1024-7B). Nine subjects were scanned on both tomographs after a single injection of [18 F]2-fluoro-2-deoxy-D-glucose. Regional and lobar gray matter metabolic rates for glucose were obtained from comparable images from each scanner. Ratios of lobar to global gray matter metabolism also were calculated. Regression coefficients and percent differences were computed to compare ECAT II and PC 1024 data. Two-thirds of the region pairs showed significant regressions, although percent differences were quite variable, with measures of glucose utilization ranging from 30 to 120% higher on the PC 1024 compared to those from the ECAT II. Comparisons of lobar glucose rates between the two machines were less variable (50 to 80%), and ratios differed by only ±5% (except for the temporal ratios). Since there was no simple and consistent relationship between regional metabolic rates on the two tomographs, an overall adjustment of regional ECAT values for comparison to PC1024 values would be impossible. A region-by-region adjustment would be necessary. Lobar ratios are sufficiently similar that direct comparisons might be possible.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The metabolic topography of normal aging
Moeller, J. R., Ishikawa, T., Dhawan, V., Spetsieris, P., Mandel, F., Alexander, G. E., Grady, C., Pietrini, P., & Eidelberg, D. (1996) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-199605000-00005 · Cited by 254
Self-citationAlkire, M. T. M., Haier, R. J. P., Shah, N. K. M., & Anderson, C. T. M. (1997) · Anesthesiology · doi:10.1097/00000542-199703000-00006 · Cited by 235
“[20] Nonetheless, regional anestheticinduced "percent changes" from baseline are directly comparable between the studies.”
ResultQuantitative EEG correlations with brain glucose metabolic rate during anesthesia in volunteers
Alkire, M. T. (1998) · Anesthesiology · doi:10.1097/00000542-199808000-00007 · Cited by 177
Alexander, G. E., & Moeller, J. R. (1994) · Human Brain Mapping · doi:10.1002/hbm.460020108 · Cited by 159
Grafton, S. T., Mazziotta, J. C., Pahl, J. J., George-Hyslop, P. S., Haines, J. L., Gusella, J., Hoffman, J. M., Baxter, L. R., & Phelps, M. E. (1992) · Archives of Neurology · doi:10.1001/archneur.1992.00530350075022 · Cited by 157
Metadata
- Authors
- Grady, C. L.
- Venue
- Journal of Cerebral Blood Flow & Metabolism
- Publisher
- SAGE Publications
- Published
- 1991-03
- Volume
- 11
- Issue
- 1_suppl
- Pages
- A57-A63
- ISSN
- 0271-678X (ISSN-L)
- 1559-7016
- OpenAlex
- W1985771550
- Cited by
- 19
- References
- 0
- FWCI
- 2.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Quantitative Comparison of Measurements of Cerebral Glucose Metabolic Rate Made with Two Positron Cameras. https://app.cochat.ai/papers/10.1038/jcbfm.1991.38
- The paper
- Grady, C. L. (1991). Quantitative Comparison of Measurements of Cerebral Glucose Metabolic Rate Made with Two Positron Cameras. Journal of Cerebral Blood Flow & Metabolism. https://doi.org/10.1038/jcbfm.1991.38
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.