Dynamic MRI Using Iron Oxide Nanoparticles to Assess Early Vascular Effects of Antiangiogenic versus Corticosteroid Treatment in a Glioma Model
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
The vascular effects of antiangiogenic treatment may pose problems for evaluating brain tumor response based on contrast-enhanced magnetic resonance imaging (MRI). We used serial dynamic contrast-enhanced MRI at 12 T to assess vascular responses to antiangiogenic versus steroid therapy. Athymic rats with intracerebral U87MG human glioma ( n = 17) underwent susceptibility-weighted perfusion MRI with ferumoxytol, a solely intravascular ultrasmall superparamagnetic iron oxide (USPIO) nanoparticle, followed by T1-weighted dynamic gadodiamide-enhanced MRI to measure vascular permeability. Rats were imaged before and after 24, 48, and 72 h of treatment with the antiangiogenic agent bevacizumab or the corticosteroid dexamethasone. Contrast agent extravasation was seen rapidly after gadodiamide, but not with ferumoxytol administration. Bevacizumab significantly decreased the blood volume and decreased permeability in tumors as determined by increased time-to-peak enhancement. A single dose of 45 mg/kg bevacizumab resulted in changes analogous to dexamethasone given in an extremely high dose (12 mg/kg per day), and was significantly more effective than dexamethasone at 2 mg/kg per day. We conclude that dynamic perfusion MRI measurements with ferumoxytol USPIO to assess cerebral blood volume, along with dynamic gadodiamide-enhanced MR to assess vascular permeability, hold promise in more accurately detecting therapeutic responses to antiangiogenic therapy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Response criteria for phase II studies of supratentorial malignant glioma.
Macdonald, D. R., Cascino, T. L., Schold, S. C., & Cairncross, J. G. (1990) · Journal of Clinical Oncology · doi:10.1200/jco.1990.8.7.1277 · Cited by 2,409 · cited 1×
“Journal of Cerebral Blood Flow & Metabolism (2009) 29, 853–860 & 2009 ISCBFM All rights reserved 0271-678X/09 $32.00 from gadolinium-based contrast agents (GBCAs) (Macdonald et al, 1990; Shah et al, 2006).”
InfluentialBatchelor, T. T., Sorensen, A. G., di Tomaso, E., Zhang, W.-T., Duda, D. G., Cohen, K. S., Kozak, K. R., Cahill, D. P., Chen, P.-J., Zhu, M., et al. (2007) · Cancer Cell · doi:10.1016/j.ccr.2006.11.021 · Cited by 1,769
Neuwelt, E. A., Hamilton, B. E., Varallyay, C. G., Rooney, W. R., Edelman, R. D., Jacobs, P. M., & Watnick, S. G. (2009) · Kidney International · doi:10.1038/ki.2008.496 · Cited by 267
Neuwelt, E. A., Várallyay, C. G., Manninger, S., Solymosi, D., Haluska, M., Hunt, M. A., Nesbit, G., Stevens, A., Jerosch-Herold, M., Jacobs, P. M., et al. (2007) · Neurosurgery · doi:10.1227/01.neu.0000255350.71700.37 · Cited by 184
Self-citation
Cited by
Weinstein, J. S., Varallyay, C. G., Dosa, E., Gahramanov, S., Hamilton, B., Rooney, W. D., Muldoon, L. L., & Neuwelt, E. A. (2010) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2009.192 · Cited by 500
Self-citationEmerging applications for ferumoxytol as a contrast agent in MRI
Bashir, M. R., Bhatti, L., Marin, D., & Nelson, R. C. (2015) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24691 · Cited by 371
Advanced MRI and PET imaging for assessment of treatment response in patients with gliomas
Dhermain, F. G., Hau, P., Lanfermann, H., Jacobs, A. H., & van den Bent, M. J. (2010) · The Lancet Neurology · doi:10.1016/s1474-4422(10)70181-2 · Cited by 368
Current and potential imaging applications of ferumoxytol for magnetic resonance imaging
Toth, G. B., Varallyay, C. G., Horvath, A., Bashir, M. R., Choyke, P. L., Daldrup-Link, H. E., Dosa, E., Finn, J. P., Gahramanov, S., Harisinghani, M., et al. (2017) · Kidney International · doi:10.1016/j.kint.2016.12.037 · Cited by 317
Self-citationPalanisamy, S., & Wang, Y.-M. (2019) · Dalton Transactions · doi:10.1039/c9dt00459a · Cited by 230
Metadata
- Authors
- Varallyay, C. G., Muldoon, L. L., Gahramanov, S., Wu, Y. J., Goodman, J. A., Li, X., Pike, M. M., & Neuwelt, E. A.
- Venue
- Journal of Cerebral Blood Flow & Metabolism
- Publisher
- SAGE Publications
- Published
- 2009-01-14
- Volume
- 29
- Issue
- 4
- Pages
- 853-860
- ISSN
- 0271-678X (ISSN-L)
- 1559-7016
- OpenAlex
- W2056440381
- Cited by
- 80
- References
- 4
- FWCI
- 5.50
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Dynamic MRI Using Iron Oxide Nanoparticles to Assess Early Vascular Effects of Antiangiogenic versus Corticosteroid Treatment in a Glioma Model. https://app.cochat.ai/papers/10.1038/jcbfm.2008.162
- The paper
- Varallyay, C. G., Muldoon, L. L., Gahramanov, S., Wu, Y. J., Goodman, J. A., Li, X., Pike, M. M., & Neuwelt, E. A. (2009). Dynamic MRI Using Iron Oxide Nanoparticles to Assess Early Vascular Effects of Antiangiogenic versus Corticosteroid Treatment in a Glioma Model. Journal of Cerebral Blood Flow & Metabolism. https://doi.org/10.1038/jcbfm.2008.162
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.