The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Visible light optical coherence tomography measures retinal oxygen metabolic response to systemic oxygenation
Open accessAbstract
The lack of capability to quantify oxygen metabolism noninvasively impedes both fundamental investigation and clinical diagnosis of a wide spectrum of diseases including all the major blinding diseases such as age-related macular degeneration, diabetic retinopathy, and glaucoma. Using visible light optical coherence tomography (vis-OCT), we demonstrated accurate and robust measurement of retinal oxygen metabolic rate (rMRO2) noninvasively in rat eyes. We continuously monitored the regulatory response of oxygen consumption to a progressive hypoxic challenge. We found that both oxygen delivery, and rMRO2 increased from the highly regulated retinal circulation (RC) under hypoxia, by 0.28 ± 0.08 µL min−1 (p < 0.001), and 0.20 ± 0.04 µL min−1 (p < 0.001) per 100 mmHg systemic pO2 reduction, respectively. The increased oxygen extraction compensated for the deficient oxygen supply from the poorly regulated choroidal circulation. Results from an oxygen diffusion model based on previous oxygen electrode measurements corroborated our in vivo observations. We believe that vis-OCT has the potential to reveal the fundamental role of oxygen metabolism in various retinal diseases. An optical scheme for monitoring the level of oxygen metabolism in the retina could aid early diagnosis of eye diseases. Ji Yi and co-workers from Northwestern University and the University of Wisconsin used visible-light optical coherence tomography to measure the retinal oxygen metabolic rate non-invasively in rat eyes. Abnormalities in the rate are associated with cell degeneration and death, and potentially act as an indicator for several retinal diseases. The optical coherence tomography system determines the rate by measuring the haemoglobin oxygen saturation and blood flow in blood vessels supplying the retina. The team performed both in vitro and in vivo measurements under a range of hypoxic conditions. Comparisons with a model and direct oxygen tension measurements using microelectrodes confirm the validity of the approach.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
From oxygen to erythropoietin: Relevance of hypoxia for retinal development, health and disease
Caprara, C., & Grimm, C. (2012) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2011.11.003 · Cited by 176
Oxygen Sensing in Retinal Health and Disease
Lange, C. A. K., & Bainbridge, J. W. B. (2012) · Ophthalmologica · doi:10.1159/000331418 · Cited by 86
Cited by
Optical coherence tomography (OCT): principle and technical realization
Aumann, S., Donner, S., Fischer, J., & Müller, F. (2019) · High Resolution Imaging in Microscopy and Ophthalmology · doi:10.1007/978-3-030-16638-0_3 · Cited by 449
Samara, W. A., Shahlaee, A., Adam, M. K., Khan, M. A., Chiang, A., Maguire, J. I., Hsu, J., & Ho, A. C. (2017) · Ophthalmology · doi:10.1016/j.ophtha.2016.10.008 · Cited by 345
Metadata
- Authors
- Yi, J., Liu, W., Chen, S., Backman, V., Sheibani, N., Sorenson, C. M., Fawzi, A. A., Linsenmeier, R. A., & Zhang, H. F.
- Venue
- Light: Science & Applications
- Published
- 2015-09-25
- Volume
- 4
- Issue
- 9
- Pages
- e334-e334
- ISSN
- 2047-7538 (ISSN-L)
- OpenAlex
- W2210198236
- Cited by
- 177
- References
- 2
- FWCI
- 8.96
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Visible light optical coherence tomography measures retinal oxygen metabolic response to systemic oxygenation. https://app.cochat.ai/papers/10.1038/lsa.2015.107
- The paper
- Yi, J., Liu, W., Chen, S., Backman, V., Sheibani, N., Sorenson, C. M., Fawzi, A. A., Linsenmeier, R. A., & Zhang, H. F. (2015). Visible light optical coherence tomography measures retinal oxygen metabolic response to systemic oxygenation. Light: Science & Applications. https://doi.org/10.1038/lsa.2015.107
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.