Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 181

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Realization of the first sub-shot-noise wide field microscope

Open access
Samantaray, Nigam, Ruo-Berchera, Ivano, Meda, Alice, Genovese, Marco · 2017 · Light: Science & Applications

Abstract

Recently, several proof of principle experiments have demonstrated the advantages of quantum technologies over classical schemes. The present challenge is to surpass the limits of proof of principle demonstrations to approach real applications. This letter presents such an achievement in the field of quantum enhanced imaging. In particular, we describe the realization of a sub-shot-noise wide field microscope based on spatially multi-mode non-classical photon number correlations in twin beams. The microscope produces realtime images of 8000 pixels at full resolution, for a 500 μm2 field of view, with noise reduced to 80% of the shot noise level (for each pixel), which is suitable for absorption imaging of complex structures. By fast post-elaboration, specifically applying a quantum enhanced median filter, the noise can be further reduced (to <30% of the shot noise level) by setting a trade-off with the resolution, thus achieving the best sensitivity per incident photon reported in absorption microscopy. A new microscope instantly captures thousands of photons from faint objects with signal-to-noise ratios exceeding classical limits. Imaging of sensitive objects, such as live cells, limits the optical power that lasers can apply. Now, Alice Meda from Italy's INRIM and colleagues have developed a microscope that ’squeezes‘ light to overcome intensity-limiting shot noise caused by quantum fluctuations of photons. Their sub-shot-noise microscope uses a nonlinear crystal to generate two high correlated light beams impossible for classical waves. Microscale pixels recorded intensities when one beam strikes a sample can have their shot noise reduced by 20% by subtracting correlated patterns from the second reference beam. This quantum-enhanced noise reduction enables the microscope to operate for high sensitive, dynamic, wide field, Q imaging applications.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/lsa.2017.5

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 181

Metadata

Authors
Samantaray, N., Ruo-Berchera, I., Meda, A., & Genovese, M.
Venue
Light: Science & Applications
Published
2017-01-28
Volume
6
Issue
7
Pages
e17005-e17005
ISSN
2047-7538 (ISSN-L)
OpenAlex
W2567527357
Cited by
181
References
4
FWCI
8.36
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.