The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Minimally invasive high-speed imaging of sarcomere contractile dynamics in mice and humans
Open accessAbstract
Sarcomeres are the basic contractile units of striated muscle. Our knowledge about sarcomere dynamics has primarily come from in vitro studies of muscle fibres and analysis of optical diffraction patterns obtained from living muscles. Both approaches involve highly invasive procedures and neither allows examination of individual sarcomeres in live subjects. Here we report direct visualization of individual sarcomeres and their dynamical length variations using minimally invasive optical microendoscopy to observe second-harmonic frequencies of light generated in the muscle fibres of live mice and humans. Using microendoscopes as small as 350 μm in diameter, we imaged individual sarcomeres in both passive and activated muscle. Our measurements permit in vivo characterization of sarcomere length changes that occur with alterations in body posture and visualization of local variations in sarcomere length not apparent in aggregate length determinations. High-speed data acquisition enabled observation of sarcomere contractile dynamics with millisecond-scale resolution. These experiments point the way to in vivo imaging studies demonstrating how sarcomere performance varies with physical conditioning and physiological state, as well as imaging diagnostics revealing how neuromuscular diseases affect contractile dynamics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
OpenSim: Open-Source Software to Create and Analyze Dynamic Simulations of Movement
Delp, S. L., Anderson, F. C., Arnold, A. S., Loan, P., Habib, A., John, C. T., Guendelman, E., & Thelen, D. G. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.901024 · Cited by 4,933
Self-citationGhrelin: Structure and Function
Kojima, M., & Kangawa, K. (2005) · Physiological Reviews · doi:10.1152/physrev.00012.2004 · Cited by 2,810
An interactive graphics-based model of the lower extremity to study orthopaedic surgical procedures
Delp, S. L., Loan, J. P., Hoy, M. G., Zajac, F. E., Topp, E. L., & Rosen, J. M. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.102791 · Cited by 2,005
Self-citationHUXLEY, H., & HANSON, J. (1954) · Nature · doi:10.1038/173973a0 · Cited by 1,751
Zipfel, W. R., Williams, R. M., Christie, R., Nikitin, A. Y., Hyman, B. T., & Webb, W. W. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0832308100 · Cited by 1,676
Structural Changes in Muscle During Contraction: Interference Microscopy of Living Muscle Fibres
HUXLEY, A. F., & NIEDERGERKE, R. (1954) · Nature · doi:10.1038/173971a0 · Cited by 1,608
Campagnola, P. J., & Loew, L. M. (2003) · Nature Biotechnology · doi:10.1038/nbt894 · Cited by 1,326
Campagnola, P. J., Millard, A. C., Terasaki, M., Hoppe, P. E., Malone, C. J., & Mohler, W. A. (2002) · Biophysical Journal · doi:10.1016/s0006-3495(02)75414-3 · Cited by 917
Zoumi, A., Yeh, A., & Tromberg, B. J. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.172368799 · Cited by 870
In Vivo Multiphoton Microscopy of Deep Brain Tissue
Levene, M. J., Dombeck, D. A., Kasischke, K. A., Molloy, R. P., & Webb, W. W. (2004) · Journal of Neurophysiology · doi:10.1152/jn.01007.2003 · Cited by 456
Cited by
Video-Rate Molecular Imaging in Vivo with Stimulated Raman Scattering
Saar, B. G., Freudiger, C. W., Reichman, J., Stanley, C. M., Holtom, G. R., & Xie, X. S. (2010) · Science · doi:10.1126/science.1197236 · Cited by 844
Skeletal muscle design to meet functional demands
Lieber, R. L., & Ward, S. R. (2011) · Philosophical Transactions of the Royal Society B: Biological Sciences · doi:10.1098/rstb.2010.0316 · Cited by 377
Two-photon excitation microscopy for the study of living cells and tissues
Benninger, R. K. P., & Piston, D. W. (2013) · Current Protocols in Cell Biology · doi:10.1002/0471143030.cb0411s59 · Cited by 311
Advances in Light Microscopy for Neuroscience
Wilt, B. A., Burns, L. D., Wei Ho, E. T., Ghosh, K. K., Mukamel, E. A., & Schnitzer, M. J. (2009) · Annual Review of Neuroscience · doi:10.1146/annurev.neuro.051508.135540 · Cited by 278
Self-citationIn vivo fluorescence imaging with high-resolution microlenses
Barretto, R. P. J., Messerschmidt, B., & Schnitzer, M. J. (2009) · Nature Methods · doi:10.1038/nmeth.1339 · Cited by 274
Self-citation
Metadata
- Authors
- Llewellyn, M. E., Barretto, R. P. J., Delp, S. L., & Schnitzer, M. J.
- Venue
- Nature
- Published
- 2008-07-06
- Volume
- 454
- Issue
- 7205
- Pages
- 784-788
- ISSN
- 0028-0836 (ISSN-L)
- 1476-4687
- OpenAlex
- W2156833447
- Cited by
- 337
- References
- 28
- FWCI
- 9.17
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Minimally invasive high-speed imaging of sarcomere contractile dynamics in mice and humans. https://app.cochat.ai/papers/10.1038/nature07104
- The paper
- Llewellyn, M. E., Barretto, R. P. J., Delp, S. L., & Schnitzer, M. J. (2008). Minimally invasive high-speed imaging of sarcomere contractile dynamics in mice and humans. Nature. https://doi.org/10.1038/nature07104
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.