The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Experimental realization of stimulated Raman shortcut-to-adiabatic passage with cold atoms
Open accessAbstract
Accurate control of a quantum system is a fundamental requirement in many areas of modern science ranging from quantum information processing to high-precision measurements. A significantly important goal in quantum control is preparing a desired state as fast as possible, with sufficiently high fidelity allowed by available resources and experimental constraints. Stimulated Raman adiabatic passage (STIRAP) is a robust way to realize high-fidelity state transfer but it requires a sufficiently long operation time to satisfy the adiabatic criteria. Here we theoretically propose and then experimentally demonstrate a shortcut-to-adiabatic protocol to speed-up the STIRAP. By modifying the shapes of the Raman pulses, we experimentally realize a fast and high-fidelity stimulated Raman shortcut-to-adiabatic passage that is robust against control parameter variations. The all-optical, robust and fast protocol demonstrated here provides an efficient and practical way to control quantum systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bason, M. G., Viteau, M., Malossi, N., Huillery, P., Arimondo, E., Ciampini, D., Fazio, R., Giovannetti, V., Mannella, R., & Morsch, O. (2012) · Nature Physics · doi:10.1038/nphys2170 · Cited by 462
Cited by
Shortcuts to adiabaticity: Concepts, methods, and applications
Guéry-Odelin, D., Ruschhaupt, A., Kiely, A., Torrontegui, E., Martínez-Garaot, S., & Muga, J. G. (2019) · Reviews of Modern Physics · doi:10.1103/revmodphys.91.045001 · Cited by 1,045
Stimulated Raman adiabatic passage in physics, chemistry, and beyond
Vitanov, N. V., Rangelov, A. A., Shore, B. W., & Bergmann, K. (2017) · Reviews of Modern Physics · doi:10.1103/revmodphys.89.015006 · Cited by 872
Molecular polaritons for controlling chemistry with quantum optics
Herrera, F., & Owrutsky, J. (2020) · The Journal of Chemical Physics · doi:10.1063/1.5136320 · Cited by 294
Accelerated quantum control using superadiabatic dynamics in a solid-state lambda system
Zhou, B. B., Baksic, A., Ribeiro, H., Yale, C. G., Heremans, F. J., Jerger, P. C., Auer, A., Burkard, G., Clerk, A. A., & Awschalom, D. D. (2017) · Nature Physics · doi:10.1038/nphys3967 · Cited by 257
Energy efficient quantum machines
Abah, O., & Lutz, E. (2017) · EPL (Europhysics Letters) · doi:10.1209/0295-5075/118/40005 · Cited by 101
Metadata
- Authors
- Du, Y.-X., Liang, Z.-T., Li, Y.-C., Yue, X.-X., Lv, Q.-X., Huang, W., Chen, X., Yan, H., & Zhu, S.-L.
- Venue
- Nature Communications
- Published
- 2016-08-11
- Volume
- 7
- Issue
- 1
- Pages
- 12479-12479
- ISSN
- 2041-1723 (ISSN-L)
- OpenAlex
- W2260423231
- Cited by
- 233
- References
- 1
- FWCI
- 14.92
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Experimental realization of stimulated Raman shortcut-to-adiabatic passage with cold atoms. https://app.cochat.ai/papers/10.1038/ncomms12479
- The paper
- Du, Y.-X., Liang, Z.-T., Li, Y.-C., Yue, X.-X., Lv, Q.-X., Huang, W., Chen, X., Yan, H., & Zhu, S.-L. (2016). Experimental realization of stimulated Raman shortcut-to-adiabatic passage with cold atoms. Nature Communications. https://doi.org/10.1038/ncomms12479
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.