The DOI matches its Crossref record.
Direct X-ray photoconversion in flexible organic thin film devices operated below 1 V
Open accessAbstract
The application of organic electronic materials for the detection of ionizing radiations is very appealing thanks to their mechanical flexibility, low-cost and simple processing in comparison to their inorganic counterpart. In this work we investigate the direct X-ray photoconversion process in organic thin film photoconductors. The devices are realized by drop casting solution-processed bis-(triisopropylsilylethynyl)pentacene (TIPS-pentacene) onto flexible plastic substrates patterned with metal electrodes; they exhibit a strong sensitivity to X-rays despite the low X-ray photon absorption typical of low-Z organic materials. We propose a model, based on the accumulation of photogenerated charges and photoconductive gain, able to describe the magnitude as well as the dynamics of the X-ray-induced photocurrent. This finding allows us to fabricate and test a flexible 2 × 2 pixelated X-ray detector operating at 0.2 V, with gain and sensitivity up to 4.7 × 10 4 and 77,000 nC mGy−1 cm−3, respectively.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Organic Photodetectors for Next‐Generation Wearable Electronics
Chow, P. C. Y., & Someya, T. (2020) · Advanced Materials · doi:10.1002/adma.201902045 · Cited by 779
Haneef, H. F., Zeidell, A. M., & Jurchescu, O. D. (2020) · Journal of Materials Chemistry C · doi:10.1039/c9tc05695e · Cited by 720
Perovskite-filled membranes for flexible and large-area direct-conversion X-ray detector arrays
Zhao, J., Zhao, L., Deng, Y., Xiao, X., Ni, Z., Xu, S., & Huang, J. (2020) · Nature Photonics · doi:10.1038/s41566-020-0678-x · Cited by 408
Halide perovskites for high-performance X-ray detector
Li, Z., Zhou, F., Yao, H., Ci, Z., Yang, Z., & Jin, Z. (2021) · Materials Today · doi:10.1016/j.mattod.2021.01.028 · Cited by 370
Jinno, H., Yokota, T., Koizumi, M., Yukita, W., Saito, M., Osaka, I., Fukuda, K., & Someya, T. (2021) · Nature Communications · doi:10.1038/s41467-021-22558-6 · Cited by 253
Metadata
- Authors
- Basiricò, L., Ciavatti, A., Cramer, T., Cosseddu, P., Bonfiglio, A., & Fraboni, B.
- Venue
- Nature Communications
- Published
- 2016-10-06
- Volume
- 7
- Issue
- 1
- Pages
- 13063-13063
- ISSN
- 2041-1723 (ISSN-L)
- OpenAlex
- W2529824253
- Cited by
- 170
- References
- 0
- FWCI
- 5.03
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Direct X-ray photoconversion in flexible organic thin film devices operated below 1 V. https://app.cochat.ai/papers/10.1038/ncomms13063
- The paper
- Basiricò, L., Ciavatti, A., Cramer, T., Cosseddu, P., Bonfiglio, A., & Fraboni, B. (2016). Direct X-ray photoconversion in flexible organic thin film devices operated below 1 V. Nature Communications. https://doi.org/10.1038/ncomms13063
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.