CoChat

Integrated arrays of air-dielectric graphene transistors as transparent active-matrix pressure sensors for wide pressure ranges

Open access
Shin, Sung-Ho, Ji, Sangyoon, Choi, Seiho, Pyo, Kyoung-Hee, Wan An, Byeong, Park, Jihun, Kim, Joohee, Kim, Ju-Young, Lee, Ki-Suk, Kwon, Soon-Yong, Heo, Jaeyeong, Park, Byong-Guk, Park, Jang-Ung · 2017 · Nature Communications

The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.

Abstract

Integrated electronic circuitries with pressure sensors have been extensively researched as a key component for emerging electronics applications such as electronic skins and health-monitoring devices. Although existing pressure sensors display high sensitivities, they can only be used for specific purposes due to the narrow range of detectable pressure (under tens of kPa) and the difficulty of forming highly integrated arrays. However, it is essential to develop tactile pressure sensors with a wide pressure range in order to use them for diverse application areas including medical diagnosis, robotics or automotive electronics. Here we report an unconventional approach for fabricating fully integrated active-matrix arrays of pressure-sensitive graphene transistors with air-dielectric layers simply formed by folding two opposing panels. Furthermore, this realizes a wide tactile pressure sensing range from 250 Pa to ∼3 MPa. Additionally, fabrication of pressure sensor arrays and transparent pressure sensors are demonstrated, suggesting their substantial promise as next-generation electronics.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/ncomms14950

Cites

32 of 32 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 Pressure-sensitive graphene FETs with air-dielectric layers. (a,b) Schematic images of pressure-sensitive graphene FETs with air-dielectric layers before (a) and after (b) the folding, respectively. The air-dielectric layer is placed between the graphene channel and the gate electrode as illustrated in the schematic image (inset). (c,d) Optical microscopy image for graphene FETs with air-dielectric layer surrounded by p-PDMS supporting walls. Scale bars, 200 μm. (c) Source, drain electrodes and graphene channel are shown. Black squares are the p-PDMS supporting walls that form the air-dielectric layer. (d) Top gate electrodes cover the air-dielectric holes by substrate folding. (e) Photograph of the fabricated pressure-sensitive graphene FETs, Scale bar, 1 cm. (f) Transfer characteristics (VD=0.1 V). (g) Output characteristics (VG=0–40 V). (h,i) Statistical distribution of the relative change in the field effect mobility of the p-type (h) and n-type (i) regimes.
Figure 1 Pressure-sensitive graphene FETs with air-dielectric layers. (a,b) Schematic images of pressure-sensitive graphene FETs with air-dielectric layers before (a) and after (b) the folding, respectively. The air-dielectric layer is placed between the graphene channel and the gate electrode as illustrated in the schematic image (inset). (c,d) Optical microscopy image for graphene FETs with air-dielectric layer surrounded by p-PDMS supporting walls. Scale bars, 200 μm. (c) Source, drain electrodes and graphene channel are shown. Black squares are the p-PDMS supporting walls that form the air-dielectric layer. (d) Top gate electrodes cover the air-dielectric holes by substrate folding. (e) Photograph of the fabricated pressure-sensitive graphene FETs, Scale bar, 1 cm. (f) Transfer characteristics (VD=0.1 V). (g) Output characteristics (VG=0–40 V). (h,i) Statistical distribution of the relative change in the field effect mobility of the p-type (h) and n-type (i) regimes.CC BY · PubMed Central
Figure 2 Electrical responses of graphene FETs to the applied pressures. (a) Schematic illustrations for the pressure sensing mechanism using an air-dielectric graphene FET. (b,c) Electrical responses of FET under different amount of applied pressures. Transfer characteristics (VD=0.1 V) (b). Output characteristics (VG=25 V) (c), respectively. (d) Plot of normalized drain current changes versus applied pressure. The inset illustrates relative change in the field effect mobility under applied pressure until ∼3 MPa showing almost constant values (error bars indicate the standard deviations calculated from the 1,000 times cyclic pressure loading test). (e) Comparison between electrical responses of the fabricated pressure sensor and true stress-strain curve from p-PDMS film compression test. (f,g) Real-time measurements of normalized drain current changes for applied pressures at VD=0.1 V and VG=25 V. The different amounts of pressure are stacked one by one sequentially representing step-like features (f). Pressure (267 kPa) is loaded and unloaded repeatedly to evaluate stable and reliable operation (g).
Figure 2 Electrical responses of graphene FETs to the applied pressures. (a) Schematic illustrations for the pressure sensing mechanism using an air-dielectric graphene FET. (b,c) Electrical responses of FET under different amount of applied pressures. Transfer characteristics (VD=0.1 V) (b). Output characteristics (VG=25 V) (c), respectively. (d) Plot of normalized drain current changes versus applied pressure. The inset illustrates relative change in the field effect mobility under applied pressure until ∼3 MPa showing almost constant values (error bars indicate the standard deviations calculated from the 1,000 times cyclic pressure loading test). (e) Comparison between electrical responses of the fabricated pressure sensor and true stress-strain curve from p-PDMS film compression test. (f,g) Real-time measurements of normalized drain current changes for applied pressures at VD=0.1 V and VG=25 V. The different amounts of pressure are stacked one by one sequentially representing step-like features (f). Pressure (267 kPa) is loaded and unloaded repeatedly to evaluate stable and reliable operation (g).CC BY · PubMed Central
Figure 3 Active-matrix pressure-sensitive FET array for spatial pressure mapping. (a) 12 × 12 active-matrix pressure-sensitive FET array sample image before air-dielectrics are covered by top gate electrodes. The holes around source and drain electrodes which form air-dielectric layer are clearly identified. Scale bar, 1 mm. (b) Corresponding electrical circuitry for 12 × 12 active-matrix sensor array which allows selective readout of electrical response. (c) Pressure mapping set-up in probe station with the pressing machine on tripod structure which delivers the pressure to the 50 × 50 pressure sensor array. Scale bar, 5 cm. (d) Contour plot showing the resultant drain current change indicating how pressure was spatially distributed. White circles show the location of tripod legs and ∼240 kPa is loaded on each spot. Scale bar, 1 mm.
Figure 3 Active-matrix pressure-sensitive FET array for spatial pressure mapping. (a) 12 × 12 active-matrix pressure-sensitive FET array sample image before air-dielectrics are covered by top gate electrodes. The holes around source and drain electrodes which form air-dielectric layer are clearly identified. Scale bar, 1 mm. (b) Corresponding electrical circuitry for 12 × 12 active-matrix sensor array which allows selective readout of electrical response. (c) Pressure mapping set-up in probe station with the pressing machine on tripod structure which delivers the pressure to the 50 × 50 pressure sensor array. Scale bar, 5 cm. (d) Contour plot showing the resultant drain current change indicating how pressure was spatially distributed. White circles show the location of tripod legs and ∼240 kPa is loaded on each spot. Scale bar, 1 mm.CC BY · PubMed Central
Figure 4 Fabrication and characterization of transparent pressure sensor. (a) Schematic illustration for the structure of transparent pressure sensor. (b,c) Optical microscopy images for FETs using AgNW-graphene hybrid electrodes with bright field and dark field, respectively. The holes forming air-dielectric layer can be identified in both images. Scale bars, 200 μm. (d,e) Transparent pressure sensor sample images before and after folding the substrate, respectively. The entire device including the substrate has the transmittance of ∼82% at a wavelength of 550 nm. Scale bars, 1 cm. (f) Transfer characteristics under different amount of applied pressure. It shows similar electrical behaviour with the non-transparent pressure sensor using Cr/Au electrodes (VD=0.1 V). (g) Output characteristics (VG=35 V). (h) Real-time measurements of normalized drain current changes for applied pressures at VD=0.1 V and VG=35 V.
Figure 4 Fabrication and characterization of transparent pressure sensor. (a) Schematic illustration for the structure of transparent pressure sensor. (b,c) Optical microscopy images for FETs using AgNW-graphene hybrid electrodes with bright field and dark field, respectively. The holes forming air-dielectric layer can be identified in both images. Scale bars, 200 μm. (d,e) Transparent pressure sensor sample images before and after folding the substrate, respectively. The entire device including the substrate has the transmittance of ∼82% at a wavelength of 550 nm. Scale bars, 1 cm. (f) Transfer characteristics under different amount of applied pressure. It shows similar electrical behaviour with the non-transparent pressure sensor using Cr/Au electrodes (VD=0.1 V). (g) Output characteristics (VG=35 V). (h) Real-time measurements of normalized drain current changes for applied pressures at VD=0.1 V and VG=35 V.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 32 references

Cited by

Items 201–206 of 206

Metadata

Authors
Shin, S.-H., Ji, S., Choi, S., Pyo, K.-H., Wan An, B., Park, J., Kim, J., Kim, J.-Y., Lee, K.-S., Kwon, S.-Y., Heo, J., Park, B.-G., & Park, J.-U.
Affiliations
  • Ulsan National Institute of Science and Technology (KR)
  • Chonnam National University (KR)
Venue
Nature Communications
Published
2017-03-31
Volume
8
Issue
1
Pages
14950-14950
ISSN
2041-1723 (ISSN-L)
OpenAlex
W2598476626
Cited by
203
References
31
Citations by year
2026: 4 · 2025: 14 · 2024: 15 · 2023: 19 · 2022: 20 · 2021: 30 · 2020: 26 · 2019: 34 · 2018: 32 · 2017: 9
FWCI
12.43
Type
journal article
Language
en
Open access
Licence
Locations
  • Nature Communications (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • RePEc: Research Papers in Economics (submittedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
  • Scholarworks@UNIST (Ulsan National Institute of Science and Technology) (submittedVersion)
Funders
  • National Research Foundation (2016R1A2B3013592, 2016R1A5A1009926)
  • Ulsan National Institute of Science and Technology (1.150090.01)
  • Ministry of Trade, Industry and Energy (2015M3A7B4050308, 10044410, 2016R1A5A1009926)
  • Korea Institute of Machinery and Materials (SC0970)
  • Samsung
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
  • Physical Sciences › Materials Science › Materials Chemistry › Graphene research and applications
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Nanomaterials and Printing Technologies
Keywords
graphene transistors, pressure sensor array, wide pressure range, transparent electronics, foldable electronics, electronic skin, health monitoring

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.