Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 188

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Ultra-sensitive optical oxygen sensors for characterization of nearly anoxic systems

Open access
Lehner, Philipp, Staudinger, Christoph, Borisov, Sergey M., Klimant, Ingo·2014·Nature Communications

Abstract

Oxygen quantification in trace amounts is essential in many fields of science and technology. Optical oxygen sensors proved invaluable tools for oxygen measurements in a broad concentration range, but until now neither optical nor electrochemical oxygen sensors were able to quantify oxygen in the sub-nanomolar concentration range. Herein we present new optical oxygen-sensing materials with unmatched sensitivity. They rely on the combination of ultra-long decaying (several 100 ms lifetime) phosphorescent boron- and aluminium-chelates, and highly oxygen-permeable and chemically stable perfluorinated polymers. The sensitivity of the new sensors is improved up to 20-fold compared with state-of-the-art analogues. The limits of detection are as low as 5 p.p.b., volume in gas phase under atmospheric pressure or 7 pM in solution. The sensors enable completely new applications for monitoring of oxygen in previously inaccessible concentration ranges. Accurately detecting low concentrations of oxygen is important in many fields, but current detection systems have limited sensitivity. Here, the authors report sensor materials based on phosphorescent boron or aluminium complexes in perfluorinated polymers, capable of detecting oxygen down to picomolar levels.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/ncomms5460

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 188

Metadata

Authors
Lehner, P., Staudinger, C., Borisov, S. M., & Klimant, I.
Venue
Nature Communications
Published
2014-07-21
Volume
5
Issue
1
Pages
4460-4460
ISSN
2041-1723 (ISSN-L)
OpenAlex
W1984138304
Cited by
188
References
1
FWCI
10.67
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Ultra-sensitive optical oxygen sensors for characterization of nearly anoxic systems. https://app.cochat.ai/papers/10.1038/ncomms5460
The paper
Lehner, P., Staudinger, C., Borisov, S. M., & Klimant, I. (2014). Ultra-sensitive optical oxygen sensors for characterization of nearly anoxic systems. Nature Communications. https://doi.org/10.1038/ncomms5460

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.