A rapid bioluminescence assay for measuring myeloperoxidase activity in human plasma
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Myeloperoxidase (MPO) is a circulating cardiovascular disease (CVD) biomarker used to estimate clinical risk and patient prognosis. Current enzyme-linked immunosorbent assays (ELISA) for MPO concentration are costly and time-intensive. Here we report a novel bioluminescence assay, designated MPO activity on a polymer surface (MAPS), for measuring MPO activity in human plasma samples using the bioluminescent substrate L-012. The method delivers a result in under an hour and is resistant to confounding effects from endogenous MPO inhibitors. In a pilot clinical study, we compared MAPS and two clinical ELISAs using 72 plasma samples from cardiac catheterization patients. Results from parallel MAPS and ELISAs were concordant within 2±11 μg l−1 MPO with similar uncertainty and reproducibility. Results between parallel MAPS and ELISA were in better agreement than those between independent ELISAs. MAPS may provide an inexpensive and rapid assay for determining MPO activity in plasma samples from patients with CVD or potentially other immune and inflammatory disorders.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Heart Disease and Stroke Statistics—2013 Update: A Report From the American Heart Association
Go, A. S., Mozaffarian, D., Roger, V. L., Benjamin, E. J., Berry, J. D., Borden, W. B., Bravata, D. M., Dai, S., Ford, E. S., Fox, C. S., et al. (2013) · Circulation · doi:10.1161/cir.0b013e31828124ad · Cited by 5,292
Ascorbate is an outstanding antioxidant in human blood plasma
Frei, B., England, L., & Ames, B. N. (1989) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.86.16.6377 · Cited by 1,870
A global view on the development of non communicable diseases
Wagner, K.-H., & Brath, H. (2012) · Preventive Medicine · doi:10.1016/j.ypmed.2011.11.012 · Cited by 362
Cited by
Schröter, J., & Schiller, J. (2016) · Oxidative Medicine and Cellular Longevity · doi:10.1155/2016/8386362 · Cited by 51
“Such methods are widely applied to monitor the HOCl-induced modification of proteins by measuring, for instance, halogenated tyrosine residues [223] and, consequently, to determine the related MPO activities [224].”
MethodLiu, T. W., Gammon, S. T., Yang, P., Fuentes, D., & Piwnica-Worms, D. (2021) · Science Signaling · doi:10.1126/scisignal.aax5971 · Cited by 27
Self-citationLiu, T. W., Gammon, S. T., Fuentes, D., & Piwnica-Worms, D. (2021) · Cells · doi:10.3390/cells10030489 · Cited by 16
Self-citation
Metadata
- Authors
- Goiffon, R. J., Martinez, S. C., & Piwnica-Worms, D.
- Venue
- Nature Communications
- Published
- 2015-02-10
- Volume
- 6
- Issue
- 1
- Pages
- 6271-6271
- ISSN
- 2041-1723 (ISSN-L)
- OpenAlex
- W1970985040
- Cited by
- 59
- References
- 3
- FWCI
- 2.06
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A rapid bioluminescence assay for measuring myeloperoxidase activity in human plasma. https://app.cochat.ai/papers/10.1038/ncomms7271
- The paper
- Goiffon, R. J., Martinez, S. C., & Piwnica-Worms, D. (2015). A rapid bioluminescence assay for measuring myeloperoxidase activity in human plasma. Nature Communications. https://doi.org/10.1038/ncomms7271
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.