The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Ultra-sensitive all-fibre photothermal spectroscopy with large dynamic range
Open accessAbstract
Photothermal interferometry is an ultra-sensitive spectroscopic means for trace chemical detection in gas- and liquid-phase materials. Previous photothermal interferometry systems used free-space optics and have limitations in efficiency of light–matter interaction, size and optical alignment, and integration into photonic circuits. Here we exploit photothermal-induced phase change in a gas-filled hollow-core photonic bandgap fibre, and demonstrate an all-fibre acetylene gas sensor with a noise equivalent concentration of 2 p.p.b. (2.3 × 10−9 cm−1 in absorption coefficient) and an unprecedented dynamic range of nearly six orders of magnitude. The realization of photothermal interferometry with low-cost near infrared semiconductor lasers and fibre-based technology allows a class of optical sensors with compact size, ultra sensitivity and selectivity, applicability to harsh environment, and capability for remote and multiplexed multi-point detection and distributed sensing.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The HITRAN2016 molecular spectroscopic database
Gordon, I. E., Rothman, L. S., Hill, C., Kochanov, R. V., Tan, Y., Bernath, P. F., Birk, M., Boudon, V., Campargue, A., Chance, K. V., et al. (2017) · Journal of Quantitative Spectroscopy and Radiative Transfer · doi:10.1016/j.jqsrt.2017.06.038 · Cited by 7,721
Russell, P. (2003) · Science · doi:10.1126/science.1079280 · Cited by 3,856
Snyder, A. W., & Love, J. D. (1984) · doi:10.1007/978-1-4613-2813-1 · Cited by 3,780
The HITRAN 2004 molecular spectroscopic database
Rothman, L. S., Jacquemart, D., Barbe, A., Chris Benner, D., Birk, M., Brown, L. R., Carleer, M. R., Chackerian, C., Chance, K., Coudert, L. H., et al. (2005) · Journal of Quantitative Spectroscopy and Radiative Transfer · doi:10.1016/j.jqsrt.2004.10.008 · Cited by 2,545
Hodgkinson, J., & Tatam, R. P. (2013) · Measurement Science and Technology · doi:10.1088/0957-0233/24/1/012004 · Cited by 1,745
Distributed Vibration Sensor Based on Coherent Detection of Phase-OTDR
Lu, Y., Zhu, T., Chen, L., & Bao, X. (2010) · Journal of Lightwave Technology · doi:10.1109/jlt.2010.2078798 · Cited by 735
Photothermal Spectroscopy Methods for Chemical Analysis
Bialkowski, S. E., & Mandelis, A. (1996) · Physics Today · doi:10.1063/1.2807813 · Cited by 567
Compact, stable and efficient all-fibre gas cells using hollow-core photonic crystal fibres
Benabid, F., Couny, F., Knight, J. C., Birks, T. A., & Russell, P. S. J. (2005) · Nature · doi:10.1038/nature03349 · Cited by 506
Ye, J., Ma, L.-S., & Hall, J. L. (1998) · Journal of the Optical Society of America B · doi:10.1364/josab.15.000006 · Cited by 396
Willer, U., Saraji, M., Khorsandi, A., Geiser, P., & Schade, W. (2006) · Optics and Lasers in Engineering · doi:10.1016/j.optlaseng.2005.04.015 · Cited by 347
Cited by
Wang, R., Vasiliev, A., Muneeb, M., Malik, A., Sprengel, S., Boehm, G., Amann, M.-C., Šimonytė, I., Vizbaras, A., Vizbaras, K., et al. (2017) · Sensors · doi:10.3390/s17081788 · Cited by 97
Metadata
- Authors
- Jin, W., Cao, Y., Yang, F., & Ho, H. L.
- Venue
- Nature Communications
- Published
- 2015-04-13
- Volume
- 6
- Issue
- 1
- Pages
- 6767-6767
- ISSN
- 2041-1723 (ISSN-L)
- OpenAlex
- W2077345659
- Cited by
- 296
- References
- 15
- FWCI
- 8.63
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.