The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Towards outperforming conventional sensor arrays with fabricated individual photonic vapour sensors inspired by Morpho butterflies
Open accessAbstract
Combining vapour sensors into arrays is an accepted compromise to mitigate poor selectivity of conventional sensors. Here we show individual nanofabricated sensors that not only selectively detect separate vapours in pristine conditions but also quantify these vapours in mixtures, and when blended with a variable moisture background. Our sensor design is inspired by the iridescent nanostructure and gradient surface chemistry of Morpho butterflies and involves physical and chemical design criteria. The physical design involves optical interference and diffraction on the fabricated periodic nanostructures and uses optical loss in the nanostructure to enhance the spectral diversity of reflectance. The chemical design uses spatially controlled nanostructure functionalization. Thus, while quantitation of analytes in the presence of variable backgrounds is challenging for most sensor arrays, we achieve this goal using individual multivariable sensors. These colorimetric sensors can be tuned for numerous vapour sensing scenarios in confined areas or as individual nodes for distributed monitoring.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Graphene nanoelectronic heterodyne sensor for rapid and sensitive vapour detection
Kulkarni, G. S., Reddy, K., Zhong, Z., & Fan, X. (2014) · Nature Communications · doi:10.1038/ncomms5376 · Cited by 189
Cited by
Sensors for Volatile Organic Compounds
Khatib, M., & Haick, H. (2022) · ACS Nano · doi:10.1021/acsnano.1c10827 · Cited by 533
Bio-Optics and Bio-Inspired Optical Materials
Tadepalli, S., Slocik, J. M., Gupta, M. K., Naik, R. R., & Singamaneni, S. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00153 · Cited by 406
Self-citationBioinspired Stimuli‐Responsive Color‐Changing Systems
Isapour, G., & Lattuada, M. (2018) · Advanced Materials · doi:10.1002/adma.201707069 · Cited by 348
Smart Gas Sensors: Recent Developments and Future Prospective
Zong, B., Wu, S., Yang, Y., Li, Q., Tao, T., & Mao, S. (2025) · Nano-Micro Letters · doi:10.1007/s40820-024-01543-w · Cited by 282
Wang, W., & Qi, L. (2019) · Advanced Functional Materials · doi:10.1002/adfm.201807275 · Cited by 256
Metadata
- Authors
- Potyrailo, R. A., Bonam, R. K., Hartley, J. G., Starkey, T. A., Vukusic, P., Vasudev, M., Bunning, T., Naik, R. R., Tang, Z., Palacios, M. A., Larsen, M., Le Tarte, L. A., Grande, J. C., Zhong, S., & Deng, T.
- Venue
- Nature Communications
- Published
- 2015-09-01
- Volume
- 6
- Issue
- 1
- Pages
- 7959-7959
- ISSN
- 2041-1723 (ISSN-L)
- OpenAlex
- W2131377088
- Cited by
- 220
- References
- 1
- FWCI
- 11.55
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Towards outperforming conventional sensor arrays with fabricated individual photonic vapour sensors inspired by Morpho butterflies. https://app.cochat.ai/papers/10.1038/ncomms8959
- The paper
- Potyrailo, R. A., Bonam, R. K., Hartley, J. G., Starkey, T. A., Vukusic, P., Vasudev, M., Bunning, T., Naik, R. R., Tang, Z., Palacios, M. A., Larsen, M., Le Tarte, L. A., Grande, J. C., Zhong, S., & Deng, T. (2015). Towards outperforming conventional sensor arrays with fabricated individual photonic vapour sensors inspired by Morpho butterflies. Nature Communications. https://doi.org/10.1038/ncomms8959
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.