The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Ultrahigh sensitivity and layer-dependent sensing performance of phosphorene-based gas sensors
Open accessAbstract
Two-dimensional (2D) layered materials have attracted significant attention for device applications because of their unique structures and outstanding properties. Here, a field-effect transistor (FET) sensor device is fabricated based on 2D phosphorene nanosheets (PNSs). The PNS sensor exhibits an ultrahigh sensitivity to NO 2 in dry air and the sensitivity is dependent on its thickness. A maximum response is observed for 4.8-nm-thick PNS, with a sensitivity up to 190% at 20 parts per billion (p.p.b.) at room temperature. First-principles calculations combined with the statistical thermodynamics modelling predict that the adsorption density is ∼10 15 cm−2 for the 4.8-nm-thick PNS when exposed to 20 p.p.b. NO 2 at 300 K. Our sensitivity modelling further suggests that the dependence of sensitivity on the PNS thickness is dictated by the band gap for thinner sheets (<10 nm) and by the effective thickness on gas adsorption for thicker sheets (>10 nm).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Generalized Gradient Approximation Made Simple
Perdew, J. P., Burke, K., & Ernzerhof, M. (1996) · Physical Review Letters · doi:10.1103/physrevlett.77.3865 · Cited by 215,824
Graphene: Status and Prospects
Geim, A. K. (2009) · Science · doi:10.1126/science.1158877 · Cited by 13,942
Graphene-based composite materials
Stankovich, S., Dikin, D. A., Dommett, G. H. B., Kohlhaas, K. M., Zimney, E. J., Stach, E. A., Piner, R. D., Nguyen, S. T., & Ruoff, R. S. (2006) · Nature · doi:10.1038/nature04969 · Cited by 12,922
Cited by
Recent development of two-dimensional transition metal dichalcogenides and their applications
Choi, W., Choudhary, N., Han, G. H., Park, J., Akinwande, D., & Lee, Y. H. (2017) · Materials Today · doi:10.1016/j.mattod.2016.10.002 · Cited by 2,769
Metallic Ti3C2T x MXene Gas Sensors with Ultrahigh Signal-to-Noise Ratio
Kim, S. J., Koh, H.-J., Ren, C. E., Kwon, O., Maleski, K., Cho, S.-Y., Anasori, B., Kim, C.-K., Choi, Y.-K., Kim, J., et al. (2018) · ACS Nano · doi:10.1021/acsnano.7b07460 · Cited by 1,699
Electrically-Transduced Chemical Sensors Based on Two-Dimensional Nanomaterials
Meng, Z., Stolz, R. M., Mendecki, L., & Mirica, K. A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00311 · Cited by 773
Applications of Phosphorene and Black Phosphorus in Energy Conversion and Storage Devices
Pang, J., Bachmatiuk, A., Yin, Y., Trzebicka, B., Zhao, L., Fu, L., Mendes, R. G., Gemming, T., Liu, Z., & Rummeli, M. H. (2018) · Advanced Energy Materials · doi:10.1002/aenm.201702093 · Cited by 518
Room-Temperature, Highly Durable Ti3C2Tx MXene/Graphene Hybrid Fibers for NH3 Gas Sensing
Lee, S. H., Eom, W., Shin, H., Ambade, R. B., Bang, J. H., Kim, H. W., & Han, T. H. (2020) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.9b21765 · Cited by 435
Metadata
- Authors
- Cui, S., Pu, H., Wells, S. A., Wen, Z., Mao, S., Chang, J., Hersam, M. C., & Chen, J.
- Venue
- Nature Communications
- Published
- 2015-10-21
- Volume
- 6
- Issue
- 1
- Pages
- 8632-8632
- ISSN
- 2041-1723 (ISSN-L)
- OpenAlex
- W2180579652
- Cited by
- 763
- References
- 3
- FWCI
- 29.19
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ultrahigh sensitivity and layer-dependent sensing performance of phosphorene-based gas sensors. https://app.cochat.ai/papers/10.1038/ncomms9632
- The paper
- Cui, S., Pu, H., Wells, S. A., Wen, Z., Mao, S., Chang, J., Hersam, M. C., & Chen, J. (2015). Ultrahigh sensitivity and layer-dependent sensing performance of phosphorene-based gas sensors. Nature Communications. https://doi.org/10.1038/ncomms9632
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.