The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Evaluation of fluorophores for optimal performance in localization-based super-resolution imaging
Open accessAbstract
One approach to super-resolution fluorescence imaging uses sequential activation and localization of individual fluorophores to achieve high spatial resolution. Essential to this technique is the choice of fluorescent probes; the properties of the probes, including photons per switching event, on-off duty cycle, photostability and number of switching cycles, largely dictate the quality of super-resolution images. Although many probes have been reported, a systematic characterization of the properties of these probes and their impact on super-resolution image quality has been described in only a few cases. Here we quantitatively characterized the switching properties of 26 organic dyes and directly related these properties to the quality of super-resolution images. This analysis provides guidelines for characterization of super-resolution probes and a resource for selecting probes based on performance. Our evaluation identified several photoswitchable dyes with good to excellent performance in four independent spectral ranges, with which we demonstrated low–cross-talk, four-color super-resolution imaging.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hell, S. W. (2007) · Science · doi:10.1126/science.1137395 · Cited by 2,967
Precise Nanometer Localization Analysis for Individual Fluorescent Probes
Thompson, R. E., Larson, D. R., & Webb, W. W. (2002) · Biophysical Journal · doi:10.1016/s0006-3495(02)75618-x · Cited by 2,320
Cited by
Super-resolution microscopy with DNA-PAINT
Schnitzbauer, J., Strauss, M. T., Schlichthaerle, T., Schueder, F., & Jungmann, R. (2017) · Nature Protocols · doi:10.1038/nprot.2017.024 · Cited by 1,047
Endoplasmic reticulum-mitochondrial contactology: structure and signaling functions
Csordás, G., Weaver, D., & Hajnóczky, G. (2018) · Trends in Cell Biology · doi:10.1016/j.tcb.2018.02.009 · Cited by 625
Low-dose metformin targets the lysosomal AMPK pathway through PEN2
Ma, T., Tian, X., Zhang, B., Li, M., Wang, Y., Yang, C., Wu, J., Wei, X., Qu, Q., Yu, Y., et al. (2022) · Nature · doi:10.1038/s41586-022-04431-8 · Cited by 644
Super-Resolution Fluorescence Imaging of Telomeres Reveals TRF2-Dependent T-loop Formation
Doksani, Y., Wu, J. Y., de Lange, T., & Zhuang, X. (2013) · Cell · doi:10.1016/j.cell.2013.09.048 · Cited by 493
Self-citationShim, S.-H., Xia, C., Zhong, G., Babcock, H. P., Vaughan, J. C., Huang, B., Wang, X., Xu, C., Bi, G.-Q., & Zhuang, X. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1201882109 · Cited by 514
Self-citation
Metadata
- Authors
- Dempsey, G. T., Vaughan, J. C., Chen, K. H., Bates, M., & Zhuang, X.
- Venue
- Nature Methods
- Published
- 2011-11-06
- Volume
- 8
- Issue
- 12
- Pages
- 1027-1036
- ISSN
- 1548-7091 (ISSN-L)
- 1548-7105
- OpenAlex
- W2133161896
- Cited by
- 1,369
- References
- 2
- FWCI
- 34.36
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.