The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Cell-surface sensors for real-time probing of cellular environments
Open accessAbstract
The ability to explore cell signalling and cell-to-cell communication is essential for understanding cell biology and developing effective therapeutics. However, it is not yet possible to monitor the interaction of cells with their environments in real time. Here, we show that a fluorescent sensor attached to a cell membrane can detect signalling molecules in the cellular environment. The sensor is an aptamer (a short length of single-stranded DNA) that binds to platelet-derived growth factor (PDGF) and contains a pair of fluorescent dyes. When bound to PDGF, the aptamer changes conformation and the dyes come closer to each other, producing a signal. The sensor, which is covalently attached to the membranes of mesenchymal stem cells, can quantitatively detect with high spatial and temporal resolution PDGF that is added in cell culture medium or secreted by neighbouring cells. The engineered stem cells retain their ability to find their way to the bone marrow and can be monitored in vivo at the single-cell level using intravital microscopy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mesenchymal Stem Cell Homing: The Devil Is in the Details
Karp, J. M., & Leng Teo, G. S. (2009) · Cell Stem Cell · doi:10.1016/j.stem.2009.02.001 · Cited by 1,445
Self-citation
Cited by
Mesenchymal stem cells: immune evasive, not immune privileged
Ankrum, J. A., Ong, J. F., & Karp, J. M. (2014) · Nature Biotechnology · doi:10.1038/nbt.2816 · Cited by 1,531
Self-citationUpconversion Luminescence-Activated DNA Nanodevice for ATP Sensing in Living Cells
Zhao, J., Gao, J., Xue, W., Di, Z., Xing, H., Lu, Y., & Li, L. (2018) · Journal of the American Chemical Society · doi:10.1021/jacs.7b11161 · Cited by 361
Bioanalytical Chemistry of Cytokines–a Review
Stenken, J. A., & Poschenrieder, A. J. (2015) · Analytica Chimica Acta · doi:10.1016/j.aca.2014.10.009 · Cited by 302
Nucleic acid aptamers in cancer research, diagnosis and therapy
Ma, H., Liu, J., Ali, M. M., Mahmood, M. A. I., Labanieh, L., Lu, M., Iqbal, S. M., Zhang, Q., Zhao, W., & Wan, Y. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00357h · Cited by 265
Self-citationNon-genetic engineering of cells for drug delivery and cell-based therapy
Wang, Q., Cheng, H., Peng, H., Zhou, H., Li, P. Y., & Langer, R. (2015) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2014.12.003 · Cited by 225
Metadata
- Authors
- Zhao, W., Schafer, S., Choi, J., Yamanaka, Y. J., Lombardi, M. L., Bose, S., Carlson, A. L., Phillips, J. A., Teo, W., Droujinine, I. A., Cui, C. H., Jain, R. K., Lammerding, J., Love, J. C., Lin, C. P., Sarkar, D., Karnik, R., & Karp, J. M.
- Venue
- Nature Nanotechnology
- Published
- 2011-07-17
- Volume
- 6
- Issue
- 8
- Pages
- 524-531
- ISSN
- 1748-3387 (ISSN-L)
- 1748-3395
- OpenAlex
- W2107984108
- Cited by
- 222
- References
- 1
- FWCI
- 7.41
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Cell-surface sensors for real-time probing of cellular environments. https://app.cochat.ai/papers/10.1038/nnano.2011.101
- The paper
- Zhao, W., Schafer, S., Choi, J., Yamanaka, Y. J., Lombardi, M. L., Bose, S., Carlson, A. L., Phillips, J. A., Teo, W., Droujinine, I. A., Cui, C. H., Jain, R. K., Lammerding, J., Love, J. C., Lin, C. P., Sarkar, D., Karnik, R., & Karp, J. M. (2011). Cell-surface sensors for real-time probing of cellular environments. Nature Nanotechnology. https://doi.org/10.1038/nnano.2011.101
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.