The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Cavity-enhanced dual-comb spectroscopy
Open accessAbstract
The sensitivity of molecular fingerprinting is dramatically improved when the absorbing sample is placed in a high-finesse optical cavity, because the effective path length is increased. When the equidistant lines from a laser frequency comb are simultaneously injected into the cavity over a large spectral range, multiple trace gases may be identified1 within a few milliseconds. However, efficient analysis of the light transmitted through the cavity remains challenging. Here, a novel approach—cavity-enhanced, frequency-comb, Fourier-transform spectroscopy—fully overcomes this difficulty and enables measurement of ultrasensitive, broad-bandwidth, high-resolution spectra within a few tens of microseconds without any need for detector arrays, potentially from the terahertz to ultraviolet regions. Within a period of just 18 µs, we recorded the spectra of the ammonia 1.0 µm overtone bands comprising 1,500 spectral elements and spanning 20 nm, with a resolution of 4.5 GHz and a noise equivalent absorption at 1 s averaging of 1 × 10−10 cm−1 Hz−1/2, thus opening a route to time-resolved spectroscopy of rapidly evolving single events. By combining Fourier transform spectroscopy with two frequency-shifted combs and cavity ring-down spectroscopy, scientists demonstrate a powerful new tool for ultrahigh sensitivity spectroscopy. The scheme can measure broadband, high-resolution spectra in tens of microseconds, does not require detector arrays and may allow tuning from terahertz to ultraviolet frequencies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Time-domain mid-infrared frequency-comb spectrometer
Keilmann, F., Gohle, C., & Holzwarth, R. (2004) · Optics Letters · doi:10.1364/ol.29.001542 · Cited by 734
Self-citationSpectrometry with frequency combs
Schiller, S. (2002) · Optics Letters · doi:10.1364/ol.27.000766 · Cited by 445
Yasui, T., Saneyoshi, E., & Araki, T. (2005) · Applied Physics Letters · doi:10.1063/1.2008379 · Cited by 265
Cited by
Coddington, I., Newbury, N., & Swann, W. (2016) · Optica · doi:10.1364/optica.3.000414 · Cited by 1,754
Schliesser, A., Picqué, N., & Hänsch, T. W. (2012) · Nature Photonics · doi:10.1038/nphoton.2012.142 · Cited by 1,436
Self-citationPicqué, N., & Hänsch, T. W. (2019) · Nature Photonics · doi:10.1038/s41566-018-0347-5 · Cited by 1,255
Self-citationMicroresonator soliton dual-comb spectroscopy
Suh, M.-G., Yang, Q.-F., Yang, K. Y., Yi, X., & Vahala, K. J. (2016) · Science · doi:10.1126/science.aah6516 · Cited by 991
Broadband electro-optic frequency comb generation in a lithium niobate microring resonator
Zhang, M., Buscaino, B., Wang, C., Shams-Ansari, A., Reimer, C., Zhu, R., Kahn, J. M., & Lončar, M. (2019) · Nature · doi:10.1038/s41586-019-1008-7 · Cited by 980
Metadata
- Authors
- Bernhardt, B., Ozawa, A., Jacquet, P., Jacquey, M., Kobayashi, Y., Udem, T., Holzwarth, R., Guelachvili, G., Hänsch, T. W., & Picqué, N.
- Venue
- Nature Photonics
- Published
- 2009-11-29
- Volume
- 4
- Issue
- 1
- Pages
- 55-57
- ISSN
- 1749-4885 (ISSN-L)
- 1749-4893
- OpenAlex
- W2028156840
- Cited by
- 594
- References
- 3
- FWCI
- 11.63
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Cavity-enhanced dual-comb spectroscopy. https://app.cochat.ai/papers/10.1038/nphoton.2009.217
- The paper
- Bernhardt, B., Ozawa, A., Jacquet, P., Jacquey, M., Kobayashi, Y., Udem, T., Holzwarth, R., Guelachvili, G., Hänsch, T. W., & Picqué, N. (2010). Cavity-enhanced dual-comb spectroscopy. Nature Photonics. https://doi.org/10.1038/nphoton.2009.217
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.