The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Quantum cascade laser frequency stabilization at the sub-Hz level
Open accessAbstract
High-precision measurements with molecules may refine our knowledge of various fields of physics, from atmospheric and interstellar physics to the standard model or physics beyond it. Most of them can be cast as absorption frequency measurements, particularly in the mid-infrared ‘molecular fingerprint’ region, creating the need for narrow-linewidth lasers of well-controlled frequency. Quantum cascade lasers provide a wide spectral coverage anywhere in the mid-infrared, but show substantial free-running frequency fluctuations. Here, we demonstrate that the excellent stability and accuracy of an ultra-stable near-infrared laser, transferred from a metrological institute through a fibre link, can be copied to a quantum cascade laser using an optical frequency comb. The obtained relative stability and accuracy of 2 × 10−15 and 10−14 exceed those demonstrated so far with quantum cascade lasers by almost two orders of magnitude. This set-up enables us to measure molecular absorption frequencies with state-of-the-art uncertainties, confirming its potential for ultra-high-precision spectroscopy. A 10 μm quantum cascade laser is phase-locked to a remote ultrastable laser referenced to primary frequency standards using an optical frequency comb. The obtained relative stability of 2 × 10−15 is record-breaking in the mid-infrared region.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A 920-Kilometer Optical Fiber Link for Frequency Metrology at the 19th Decimal Place
Predehl, K., Grosche, G., Raupach, S. M. F., Droste, S., Terra, O., Alnis, J., Legero, T., Hänsch, T. W., Udem, T., Holzwarth, R., et al. (2012) · Science · doi:10.1126/science.1218442 · Cited by 543
Ultra-stable long distance optical frequency distribution using the Internet fiber network
Lopez, O., Haboucha, A., Chanteau, B., Chardonnet, C., Amy-Klein, A., & Santarelli, G. (2012) · Optics Express · doi:10.1364/oe.20.023518 · Cited by 175
Self-citation
Cited by
Quantum cascade lasers: 20 years of challenges
Vitiello, M. S., Scalari, G., Williams, B., & De Natale, P. (2015) · Optics Express · doi:10.1364/oe.23.005167 · Cited by 512
Mehlstäubler, T. E., Grosche, G., Lisdat, C., Schmidt, P. O., & Denker, H. (2018) · Reports on Progress in Physics · doi:10.1088/1361-6633/aab409 · Cited by 263
A phase-stable dual-comb interferometer
Chen, Z., Yan, M., Hänsch, T. W., & Picqué, N. (2018) · Nature Communications · doi:10.1038/s41467-018-05509-6 · Cited by 139
Schioppo, M., Kronjäger, J., Silva, A., Ilieva, R., Paterson, J. W., Baynham, C. F. A., Bowden, W., Hill, I. R., Hobson, R., Vianello, A., et al. (2022) · Nature Communications · doi:10.1038/s41467-021-27884-3 · Cited by 118
Self-citationCommon-clock very long baseline interferometry using a coherent optical fiber link
Clivati, C., Aiello, R., Bianco, G., Bortolotti, C., De Natale, P., Di Sarno, V., Maddaloni, P., Maccaferri, G., Mura, A., Negusini, M., et al. (2020) · Optica · doi:10.1364/optica.393356 · Cited by 99
Metadata
- Authors
- Argence, B., Chanteau, B., Lopez, O., Nicolodi, D., Abgrall, M., Chardonnet, C., Daussy, C., Darquié, B., Le Coq, Y., & Amy-Klein, A.
- Venue
- Nature Photonics
- Published
- 2015-06-08
- Volume
- 9
- Issue
- 7
- Pages
- 456-460
- ISSN
- 1749-4885 (ISSN-L)
- 1749-4893
- OpenAlex
- W1481037693
- Cited by
- 162
- References
- 2
- FWCI
- 6.93
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Quantum cascade laser frequency stabilization at the sub-Hz level. https://app.cochat.ai/papers/10.1038/nphoton.2015.93
- The paper
- Argence, B., Chanteau, B., Lopez, O., Nicolodi, D., Abgrall, M., Chardonnet, C., Daussy, C., Darquié, B., Le Coq, Y., & Amy-Klein, A. (2015). Quantum cascade laser frequency stabilization at the sub-Hz level. Nature Photonics. https://doi.org/10.1038/nphoton.2015.93
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.