The DOI matches its Crossref record; 73 of the 73 references it cites were found in a registry or an index.
Comparing ultrastable lasers at 7 × 10−17 fractional frequency instability through a 2220 km optical fibre network
Open accessAbstract
Ultrastable lasers are essential tools in optical frequency metrology enabling unprecedented measurement precision that impacts on fields such as atomic timekeeping, tests of fundamental physics, and geodesy. To characterise an ultrastable laser it needs to be compared with a laser of similar performance, but a suitable system may not be available locally. Here, we report a comparison of two geographically separated lasers, over the longest ever reported metrological optical fibre link network, measuring 2220 km in length, at a state-of-the-art fractional-frequency instability of 7 × 10 −17 for averaging times between 30 s and 200 s. The measurements also allow the short-term instability of the complete optical fibre link network to be directly observed without using a loop-back fibre. Based on the characterisation of the noise in the lasers and optical fibre link network over different timescales, we investigate the potential for disseminating ultrastable light to improve the performance of remote optical clocks.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures





Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“Furthermore, the frequency of two atomic clocks can be compared via an interferometric fiber link (IFL), which supports sub-10 -19 accuracy over hundreds of kilometers [5-10].”
From Long-distance chronometric leveling with a portable optical clock (2024) · cites this paper as [10]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A fully photonics-based coherent radar system
Ghelfi, P., Laghezza, F., Scotti, F., Serafino, G., Capria, A., Pinna, S., Onori, D., Porzi, C., Scaffardi, M., Malacarne, A., et al. (2014) · Nature · doi:10.1038/nature13078 · Cited by 1,111
Atomic clock performance enabling geodesy below the centimetre level
McGrew, W. F., Zhang, X., Fasano, R. J., Schäffer, S. A., Beloy, K., Nicolodi, D., Brown, R. C., Hinkley, N., Milani, G., Schioppo, M., et al. (2018) · Nature · doi:10.1038/s41586-018-0738-2 · Cited by 727
Self-citation(2019) · doi:10.1103/physrevlett.123.033201 · Cited by 711
Single-Ion Atomic Clock with 3 × 10 − 18 Systematic Uncertainty
Huntemann, N., Sanner, C., Lipphardt, B., Tamm, C., & Peik, E. (2016) · Physical Review Letters · doi:10.1103/physrevlett.116.063001 · Cited by 677 · cited 1×
“This observation is important as it makes the advent of more stable lasers beneficial to the effectiveness of the clean-up oscillator scheme in two concurrent ways: (1) as just discussed it increases TRabi, reducing the atomic sensitivity to link noise, (2) it widens the separation between the frequency where the link…”
BackgroundQuantum projection noise: Population fluctuations in two-level systems
Itano, W. M., Bergquist, J. C., Bollinger, J. J., Gilligan, J. M., Heinzen, D. J., Moore, F. L., Raizen, M. G., & Wineland, D. J. (1993) · Physical Review A · doi:10.1103/physreva.47.3554 · Cited by 613
1.5 μm Lasers with Sub-10 mHz Linewidth
Matei, D. G., Legero, T., Häfner, S., Grebing, C., Weyrich, R., Zhang, W., Sonderhouse, L., Robinson, J. M., Ye, J., Riehle, F., et al. (2017) · Physical Review Letters · doi:10.1103/physrevlett.118.263202 · Cited by 584
Self-citationThermal-Noise Limit in the Frequency Stabilization of Lasers with Rigid Cavities
Numata, K., Kemery, A., & Camp, J. (2004) · Physical Review Letters · doi:10.1103/physrevlett.93.250602 · Cited by 554
Test of general relativity by a pair of transportable optical lattice clocks
Takamoto, M., Ushijima, I., Ohmae, N., Yahagi, T., Kokado, K., Shinkai, H., & Katori, H. (2020) · Nature Photonics · doi:10.1038/s41566-020-0619-8 · Cited by 507
Geodesy and metrology with a transportable optical clock
Grotti, J., Koller, S., Vogt, S., Häfner, S., Sterr, U., Lisdat, C., Denker, H., Voigt, C., Timmen, L., Rolland, A., et al. (2018) · Nature Physics · doi:10.1038/s41567-017-0042-3 · Cited by 495
Self-citationDemonstration of 4.8 × 10−17 stability at 1 s for two independent optical clocks
Oelker, E., Hutson, R. B., Kennedy, C. J., Sonderhouse, L., Bothwell, T., Goban, A., Kedar, D., Sanner, C., Robinson, J. M., Marti, G. E., et al. (2019) · Nature Photonics · doi:10.1038/s41566-019-0493-4 · Cited by 475
Self-citation
Research works printed but not linked: 2
- Dick, J. G. Local oscillator induced instabilities in trapped ion frequency standards. In Proceedings of the 19th Annual Precise Time and Time Interval Meeting, 133-147 (US Naval Observatory, 1988).
- Bowden, W., Vianello, A., Hill, I. R., Schioppo, M. & Hobson, R. Improving the Q factor of an optical atomic clock using quantum nondemolition measurement. Phys. Rev. X 10, 041052 (2020).
Cited by
Roadmap towards the redefinition of the second
Dimarcq, N., Gertsvolf, M., Mileti, G., Bize, S., Oates, C. W., Peik, E., Calonico, D., Ido, T., Tavella, P., Meynadier, F., et al. (2023) · Metrologia · doi:10.1088/1681-7575/ad17d2 · Cited by 205
Self-citationReview on Charge Carrier Transport in Inorganic and Organic Semiconductors
Morab, S., Minakshi, M., & Pivrikas, A. (2023) · Coatings · doi:10.3390/coatings13091657 · Cited by 117
Measuring the stability of fundamental constants with a network of clocks
Barontini, G., Blackburn, L., Boyer, V., Butuc-Mayer, F., Calmet, X., López-Urrutia, J. R. C., Curtis, E. A., Darquié, B., Dunningham, J., Fitch, N. J., et al. (2022) · EPJ Quantum Technology · doi:10.1140/epjqt/s40507-022-00130-5 · Cited by 92
Self-citationAnalysis of atomic-clock data to constrain variations of fundamental constants
Sherrill, N., Parsons, A. O., Baynham, C. F. A., Bowden, W., Curtis, E. A., Hendricks, R., Hill, I. R., Hobson, R., Margolis, H. S., Robertson, B., et al. (2023) · New Journal of Physics · doi:10.1088/1367-2630/aceff6 · Cited by 96
Self-citationSilicon nitride stress-optic microresonator modulator for optical control applications
Wang, J., Liu, K., Harrington, M., Rudy, R. Q., & Blumenthal, D. J. (2022) · Optics Express · doi:10.1364/oe.467721 · Cited by 77
Metadata
- Authors
- Schioppo, M., Kronjäger, J., Silva, A., Ilieva, R., Paterson, J. W., Baynham, C. F. A., Bowden, W., Hill, I. R., Hobson, R., Vianello, A., Dovale-Álvarez, M., Williams, R. A., Marra, G., Margolis, H. S., Amy-Klein, A., Lopez, O., Cantin, E., Álvarez-Martínez, H., Le Targat, R., Pottie, P. E., Quintin, N., Legero, T., Häfner, S., Sterr, U., Schwarz, R., Dörscher, S., Lisdat, C., Koke, S., Kuhl, A., Waterholter, T., Benkler, E., & Grosche, G.
- Affiliations
- National Physical Laboratory (GB)
- Centre National de la Recherche Scientifique (FR)
- Renater (FR)
- Physikalisch-Technische Bundesanstalt (DE)
- Corresponding author
- Schioppo, M.
- Kronjäger, J.
- ORCID
- Venue
- Nature Communications
- Published
- 2022-01-11
- Volume
- 13
- Issue
- 1
- Pages
- 212-212
- ISSN
- 2041-1723 (ISSN-L)
- PMC
- PMC8752831
- OpenAlex
- W4206606030
- Cited by
- 118
- References
- 69
- Citations by year
- 2026: 18 · 2025: 32 · 2024: 39 · 2023: 17 · 2022: 12
- FWCI
- 10.25
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/4.0 (tdm)
- creativecommons.org/licenses/by/4.0 (vor)
- Locations
- Nature Communications (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- HAL (submittedVersion, other-oa)
- RePEc: Research Papers in Economics (submittedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- UCL Discovery (University College London) (submittedVersion)
- Zenodo (CERN European Organization for Nuclear Research) (submittedVersion, cc-by)
- Funders
- Equipex
- European Commission (18SIB05 ROCIT, HORIZON2020, 15SIB03 OC18)
- Deutsche Forschungsgemeinschaft (CRC 1227 (DQ-mat, 434617780, EXC-2123 Quantum Frontiers, 390837967, CRC 1464, CRC 1227, 274200144, (EXC 2123)
- Agence Nationale de la Recherche (ANR 10 LABX 48 01, ANR-10-LABX-0048, 15SIB03, ANR-10-IDEX-0001, 15SIB03 OC18, 10-LABX-48-01, ANR-10-LABX-48, ANR-10-IDEX, ANR-11-EQPX-0039, ANR-10, ANR-10-LABX)
- Institut Francilien de Recherche sur les Atomes Froids
- Engineering and Physical Sciences Research Council (EP/L016524/, EP/L016524/1)
- European Metrology Programme for Innovation and Research (18SIB06 (TiFOON), 15SIB03 “OC18”, 15SIB05 “OFTEN”, 15SIB03, 15SIB05, 18SIB05 ROCIT, 18SIB05, 18SIB06)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Frequency and Time Standards
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Fiber Laser Technologies
- Physical Sciences › Physics and Astronomy › Instrumentation › Scientific Measurement and Uncertainty Evaluation
- Keywords
- ultra-stable lasers, fractional frequency instability, optical frequency metrology
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparing ultrastable lasers at 7 × 10−17 fractional frequency instability through a 2220 km optical fibre network. https://app.cochat.ai/papers/10.1038/s41467-021-27884-3
- The paper
- Schioppo, M., Kronjäger, J., Silva, A., Ilieva, R., Paterson, J. W., Baynham, C. F. A., Bowden, W., Hill, I. R., Hobson, R., Vianello, A., Dovale-Álvarez, M., Williams, R. A., Marra, G., Margolis, H. S., Amy-Klein, A., Lopez, O., Cantin, E., Álvarez-Martínez, H., Le Targat, R., . . . Grosche, G. (2022). Comparing ultrastable lasers at 7 × 10−17 fractional frequency instability through a 2220 km optical fibre network. Nature Communications. https://doi.org/10.1038/s41467-021-27884-3
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.