The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Multiparametric analysis of cells with different mitochondrial membrane potential during apoptosis by polychromatic flow cytometry
Open accessAbstract
The analysis of changes in mitochondrial membrane potential (MMP) that can occur during apoptosis provides precious information on the mechanisms and pathways of cell death. For many years, the metachromatic fluorochrome JC-1 (5,5′,6,6′-tetrachloro-1,1′,3,3′-tetraethylbenzimidazolcarbocyanine iodide) was used for this purpose. Thanks to new dyes and to the technical improvements recently adopted in several flow cytometers, it is now possible to investigate, along with MMP, a variety of other parameters. Using three sources of excitation and polychromatic flow cytometry, we have developed a protocol that can be applied to cells undergoing apoptosis. In the model of U937 cells incubated with the chemopreventive agent quercetin (3,3′,4′,5,7-pentahydroxyflavone), we describe the detection at the single cell level of changes in MMP (by JC-1), early apoptosis (exposition of phosphatidylserine on the plasma membrane detected by annexin-V), late apoptosis and secondary necrosis (decreased DNA content by Hoechst 33342 and permeability of the plasma membrane to propidium iodide). The procedure can be completed in less than 2 h.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mitochondrial membrane permeabilization in cell death
Kroemer, G., Galluzzi, L., & Brenner, C. (2007) · Physiological Reviews · doi:10.1152/physrev.00013.2006 · Cited by 3,598
Ankarcrona, M., Dypbukt, J. M., Bonfoco, E., Zhivotovsky, B., Orrenius, S., Lipton, S. A., & Nicotera, P. (1995) · Neuron · doi:10.1016/0896-6273(95)90186-8 · Cited by 1,884
Cited by
Mesenchymal stem cells use extracellular vesicles to outsource mitophagy and shuttle microRNAs
Phinney, D. G., Di Giuseppe, M., Njah, J., Sala, E., Shiva, S., St Croix, C. M., Stolz, D. B., Watkins, S. C., Di, Y. P., Leikauf, G. D., et al. (2015) · Nature Communications · doi:10.1038/ncomms9472 · Cited by 1,007
Guidelines for the use of flow cytometry and cell sorting in immunological studies (second edition)
Cossarizza, A., Chang, H., Radbruch, A., Acs, A., Adam, D., Adam‐Klages, S., Agace, W. W., Aghaeepour, N., Akdis, M., Allez, M., et al. (2019) · European Journal of Immunology · doi:10.1002/eji.201970107 · Cited by 979
Self-citationWang, Y., Xu, C.-F., Liu, Y.-J., Mao, Y.-F., Lv, Z., Li, S.-Y., Zhu, X.-Y., & Jiang, L. (2017) · Cellular Physiology and Biochemistry · doi:10.1159/000477112 · Cited by 825
Guidelines for the use of flow cytometry and cell sorting in immunological studies *
Cossarizza, A., Chang, H., Radbruch, A., Akdis, M., Andrä, I., Annunziato, F., Bacher, P., Barnaba, V., Battistini, L., Bauer, W. M., et al. (2017) · European Journal of Immunology · doi:10.1002/eji.201646632 · Cited by 542
Self-citationThe selective detection of mitochondrial superoxide by live cell imaging
Robinson, K. M., Janes, M. S., & Beckman, J. S. (2008) · Nature Protocols · doi:10.1038/nprot.2008.56 · Cited by 262
Metadata
- Authors
- Troiano, L., Ferraresi, R., Lugli, E., Nemes, E., Roat, E., Nasi, M., Pinti, M., & Cossarizza, A.
- Venue
- Nature Protocols
- Published
- 2007-10-25
- Volume
- 2
- Issue
- 11
- Pages
- 2719-2727
- ISSN
- 1750-2799 (ISSN-L)
- 1754-2189
- OpenAlex
- W1998947557
- Cited by
- 168
- References
- 2
- FWCI
- 3.71
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.