The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Screening individual hybridomas by microengraving to discover monoclonal antibodies
Open accessAbstract
The demand for monoclonal antibodies (mAbs) in biomedical research is significant, but the current methodologies used to discover them are both lengthy and costly. Consequently, the diversity of antibodies available for any particular antigen remains limited. Microengraving is a soft lithographic technique that provides a rapid and efficient alternative for discovering new mAbs. This protocol describes how to use microengraving to screen mouse hybridomas to establish new cell lines producing unique mAbs. Single cells from a polyclonal population are isolated into an array of microscale wells (∼105 cells per screen). The array is then used to print a protein microarray, where each element contains the antibodies captured from individual wells. The antibodies on the microarray are screened with antigens of interest, and mapped to the corresponding cells, which are then recovered from their microwells by micromanipulation. Screening and retrieval require approximately 1–3 d (9–12 d including the steps for preparing arrays of microwells).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Passive immunity in prevention and treatment of infectious diseases
Keller, M. A., & Stiehm, E. R. (2000) · Clinical Microbiology Reviews · doi:10.1128/cmr.13.4.602 · Cited by 388
Cited by
Soft lithography for micro- and nanoscale patterning
Qin, D., Xia, Y., & Whitesides, G. M. (2010) · Nature Protocols · doi:10.1038/nprot.2009.234 · Cited by 2,334
Development of therapeutic antibodies for the treatment of diseases
Lu, R.-M., Hwang, Y.-C., Liu, I.-J., Lee, C.-C., Tsai, H.-Z., Li, H.-J., & Wu, H.-C. (2020) · Journal of Biomedical Science · doi:10.1186/s12929-019-0592-z · Cited by 2,085
High-throughput sequencing of the paired human immunoglobulin heavy and light chain repertoire
DeKosky, B. J., Ippolito, G. C., Deschner, R. P., Lavinder, J. J., Wine, Y., Rawlings, B. M., Varadarajan, N., Giesecke, C., Dörner, T., Andrews, S. F., et al. (2013) · Nature Biotechnology · doi:10.1038/nbt.2492 · Cited by 410
Functional single-cell hybridoma screening using droplet-based microfluidics
Debs, B. E., Utharala, R., Balyasnikova, I. V., Griffiths, A. D., & Merten, C. A. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1204514109 · Cited by 276
Chip in a lab: microfluidics for next generation life science research
Streets, A. M., & Huang, Y. (2013) · Biomicrofluidics · doi:10.1063/1.4789751 · Cited by 180
Metadata
- Authors
- Ogunniyi, A. O., Story, C. M., Papa, E., Guillen, E., & Love, J. C.
- Venue
- Nature Protocols
- Published
- 2009-04-30
- Volume
- 4
- Issue
- 5
- Pages
- 767-782
- ISSN
- 1750-2799 (ISSN-L)
- 1754-2189
- OpenAlex
- W2161872640
- Cited by
- 164
- References
- 1
- FWCI
- 5.16
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Screening individual hybridomas by microengraving to discover monoclonal antibodies. https://app.cochat.ai/papers/10.1038/nprot.2009.40
- The paper
- Ogunniyi, A. O., Story, C. M., Papa, E., Guillen, E., & Love, J. C. (2009). Screening individual hybridomas by microengraving to discover monoclonal antibodies. Nature Protocols. https://doi.org/10.1038/nprot.2009.40
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.