The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Validation and Calibration of Physical Activity Monitors in Children
Abstract
Objective: This study was designed to validate accelerometer‐based activity monitors against energy expenditure (EE) in children; to compare monitor placement sites; to field‐test the monitors; and to establish sedentary, light, moderate, and vigorous threshold counts. Research Methods and Procedures: Computer Science and Applications Actigraph (CSA) and Mini‐Mitter Actiwatch (MM) monitors, on the hip or lower leg, were validated and calibrated against 6‐hour EE measurements by room respiration calorimetry, activity by microwave detector, and heart rate by telemetry in 26 children, 6 to 16 years old. During the 6 hours, the children performed structured activities, including resting metabolic rate (RMR), Nintendo, arts and crafts, aerobic warm‐up, Tae Bo, treadmill walking and running, and games. Activity energy expenditure (AEE) computed as EE − RMR was regressed against counts to derive threshold counts. Results: The mean correlations between EE or AEE and counts were slightly higher for MM‐hip (r = 0.78 ± 0.06) and MM‐leg (r = 0.80 ± 0.05) than CSA‐hip (r = 0.66 ± 0.08) and CSA‐leg (r = 0.73 ± 0.07). CSA and MM performed similarly on the hip (inter‐instrument r = 0.88) and on the lower leg (inter‐instrument r = 0.89). Threshold counts for the CSA‐hip were <800, <3200, <8200, and ≥8200 for sedentary, light, moderate, and vigorous categories, respectively. For the MM‐hip, the threshold counts were <100, <900, <2200, and ≥2200, respectively. Discussion: The validation of the CSA and MM monitors against AEE and their calibration for sedentary, light, moderate, and vigorous thresholds certify these monitors as valid, useful devices for the assessment of physical activity in children.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Calibration of the Computer Science and Applications, Inc. accelerometer
FREEDSON, P. S., MELANSON, E., & SIRARD, J. (1998) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199805000-00021 · Cited by 3,825
Cited by
Calibration of two objective measures of physical activity for children
Evenson, K. R., Catellier, D. J., Gill, K., Ondrak, K. S., & McMurray, R. G. (2008) · Journal of Sports Sciences · doi:10.1080/02640410802334196 · Cited by 2,677
Conducting accelerometer-based activity assessments in field-based research
TROST, S. G., MCIVER, K. L., & PATE, R. R. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185657.86065.98 · Cited by 2,033
Comparison of Accelerometer Cut Points for Predicting Activity Intensity in Youth
TROST, S. G., LOPRINZI, P. D., MOORE, R., & PFEIFFER, K. A. (2011) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e318206476e · Cited by 1,360
Ekelund, U. (2012) · JAMA · doi:10.1001/jama.2012.156 · Cited by 1,158
Metcalf, B., Henley, W., & Wilkin, T. (2012) · BMJ · doi:10.1136/bmj.e5888 · Cited by 658
Metadata
- Authors
- Puyau, M. R., Adolph, A. L., Vohra, F. A., & Butte, N. F.
- Venue
- Obesity Research
- Publisher
- Wiley
- Published
- 2002-03
- Volume
- 10
- Issue
- 3
- Pages
- 150-157
- ISSN
- 1071-7323 (ISSN-L)
- 1550-8528
- OpenAlex
- W1973607582
- Cited by
- 1,023
- References
- 1
- FWCI
- 13.23
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Validation and Calibration of Physical Activity Monitors in Children. https://app.cochat.ai/papers/10.1038/oby.2002.24
- The paper
- Puyau, M. R., Adolph, A. L., Vohra, F. A., & Butte, N. F. (2002). Validation and Calibration of Physical Activity Monitors in Children. Obesity Research. https://doi.org/10.1038/oby.2002.24
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.