Volume Estimates by Imaging Methods: Model Comparisons with Visible Woman as the Reference
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Objective: To compare the accuracy of four volume estimation models to actual tissue and organ volumes measured in the visible woman. Methods: Actual volumes were calculated from 1‐mm‐thick visible woman images that were segmented for five major components including subcutaneous and visceral adipose tissue across the 1730 available slices. Four available models resolved to two equations: truncated cone/truncated pyramid vs. two‐column/parallel trapezium. Between‐slice interval and initial slice were systematically varied when deriving component volumes using the two equations in four regions. Results: For each compartment and each between‐slice interval, the means of the two‐column model were always the same as the corresponding reference volumes, whereas those of the truncated cone model were smaller than the reference volumes. Similarly, the coefficient variation for the two‐column model was always smaller than for the truncated cone model. Discussion: The equation based on the parallel trapezium and the two‐column models is more accurate in estimating tissue volumes than the corresponding equation for truncated pyramid and truncated cone models. This finding has important implications for the volume calculations of imaging‐based body compartments such as adipose tissue.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Seidell, J., Bakker, C., & van der Kooy, K. (1990) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/51.6.953 · Cited by 375
Muscularity in adult humans: Proportion of adipose tissue‐free body mass as skeletal muscle
Wang, Z., Heo, M., Lee, R. C., Kotler, D. P., Withers, R. T., & Heymsfield, S. B. (2001) · American Journal of Human Biology · doi:10.1002/ajhb.1099 · Cited by 82
Self-citation
Cited by
Shen, W., Punyanitya, M., Wang, Z., Gallagher, D., St.-Onge, M.-P., Albu, J., Heymsfield, S. B., & Heshka, S. (2004) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00744.2004 · Cited by 1,692
Self-citationFat Distribution in Men With HIV Infection
(2005) · JAIDS Journal of Acquired Immune Deficiency Syndromes · doi:10.1097/01.qai.0000182230.47819.aa · Cited by 328
Contemporary methods of body composition measurement
Fosbøl, M. Ø., & Zerahn, B. (2015) · Clinical Physiology and Functional Imaging · doi:10.1111/cpf.12152 · Cited by 279
Grunfeld, C., Rimland, D., Gibert, C. L., Powderly, W. G., Sidney, S., Shlipak, M. G., Bacchetti, P., Scherzer, R., Haffner, S. M., & Heymsfield, S. B. (2007) · JAIDS Journal of Acquired Immune Deficiency Syndromes · doi:10.1097/qai.0b013e31814b94e2 · Cited by 114
“Volume of each tissue for the space between 2 consecutive slices was calculated by means of a mathematic algorithm.(25) Glucose and insulin were measured in a central laboratory (Linco Research, St.”
MethodSelf-citationZhao, X., Wang, Z., Zhang, J., Hua, J., He, W., & Zhu, S. (2013) · PLoS ONE · doi:10.1371/journal.pone.0053561 · Cited by 39
“thickness (10 mm) of each image, h (40 mm) is the distance between consecutive images and Ai is each image’s cross sectional area [23].”
BackgroundSelf-citation
Metadata
- Authors
- Shen, W., Wang, Z., Tang, H., Heshka, S., Punyanitya, M., Zhu, S., Lei, J., & Heymsfield, S. B.
- Venue
- Obesity Research
- Publisher
- Wiley
- Published
- 2003-02
- Volume
- 11
- Issue
- 2
- Pages
- 217-225
- ISSN
- 1071-7323 (ISSN-L)
- 1550-8528
- OpenAlex
- W2105593880
- Cited by
- 76
- References
- 2
- FWCI
- 1.45
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.