CoChat

The Intra‐ and Inter‐instrument Reliability of DXA Based on Ex Vivo Soft Tissue Measurements

Open access
Guo, Yan, Franks, Paul W., Brookshire, Thomas, Tataranni, P. Antonio · 2004 · Obesity Research
Cited by 84

The DOI matches its Crossref record.

Abstract

Objective: Comparison of ex‐vivo soft tissue measurements using the GE/Lunar pencil (DPX‐L; GE/Lunar Co., Madison, WI) and fan beam (Prodigy dual‐energy X‐ray absorptiometers (DXA) GE/Lunar Co.). Research Methods and Procedures: Intra‐instrument reliability was assessed by repeatedly scanning soft tissue phantoms for lean tissue (water) and fat tissue (methanol) using one DPX‐L and two identical Prodigy DXAs at fast, medium, and slow scan modes. For each machine, 10 scans of each phantom were performed at each scan speed. The number of scans per instrument totaled 60. Data were analyzed using ANOVA to ascertain whether scan speed affected the intra‐instrument reliability and to test whether soft tissue measurements differed among instruments. Percentage fat (phantom density) was the outcome variable. Results: Intra‐instrument reliability, expressed as coefficient of variation, ranged between 0.7% and 5.2% for the DPX‐L and 0.4% and 4.5% for the Prodigy, with the lowest coefficients of variation observed when scanning the fat tissue phantom. Scan speed also affected the intra‐instrument reliability (p < 0.01). Furthermore, differences in the measurement of percentage body fat for both the lean and fat tissue phantoms were observed among all three absorptiometers (all p < 0.01). After adjusting for scan speed, differences persisted for all three instruments. Discussion: Intra‐ and inter‐instrument reliability of DXA machines, even those from the same manufacturer, remains unpredictable. Thus, when measuring body composition using DXA, it is important to consider that even in the absence of measurement bias, the use of different DXA machines, particularly when using a variety of speed settings, will increase the residual error around the true value.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/oby.2004.241

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 84

Metadata

Authors
Guo, Y., Franks, P. W., Brookshire, T., & Tataranni, P. A.
Venue
Obesity Research
Publisher
Wiley
Published
2004-12
Volume
12
Issue
12
Pages
1925-1929
ISSN
  • 1071-7323 (ISSN-L)
  • 1550-8528
OpenAlex
W2091212860
Cited by
84
References
0
FWCI
0.57
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The Intra‐ and Inter‐instrument Reliability of DXA Based on Ex Vivo Soft Tissue Measurements. https://app.cochat.ai/papers/10.1038/oby.2004.241
The paper
Guo, Y., Franks, P. W., Brookshire, T., & Tataranni, P. A. (2004). The Intra‐ and Inter‐instrument Reliability of DXA Based on Ex Vivo Soft Tissue Measurements. Obesity Research. https://doi.org/10.1038/oby.2004.241

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.