Estimation of Free‐Living Energy Expenditure Using a Novel Activity Monitor Designed to Minimize Obtrusiveness
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
The aim of this study was to investigate the ability of a novel activity monitor designed to be minimally obtrusive in predicting free‐living energy expenditure. Subjects were 18 men and 12 women (age: 41 ± 11 years, BMI: 24.4 ± 3 kg/m 2). The habitual physical activity was monitored for 14 days using a DirectLife triaxial accelerometer for movement registration (Tracmor D) (Philips New Wellness Solutions, Lifestyle Incubator, the Netherlands). Tracmor D output was expressed as activity counts per day (Cnts/d). Simultaneously, total energy expenditure (TEE) was measured in free living conditions using doubly labeled water (DLW). Activity energy expenditure (AEE) and the physical activity level (PAL) were determined from TEE and sleeping metabolic rate (SMR). A multiple‐linear regression model predicted 76% of the variance in TEE, using as independent variables SMR (partial‐r2 = 0.55, P < 0.001), and Cnts/d (partial r2 = 0.21, P < 0.001). The s.e. of TEE estimates was 0.9 MJ/day or 7.4% of the average TEE. A model based on body mass (partial‐r2 = 0.31, P < 0.001) and Cnts/d (partial‐r2 = 0.23, P < 0.001) predicted 54% of the variance in TEE. Cnts/d were significantly and positively associated with AEE (r = 0.54, P < 0.01), PAL (r = 0.68, P < 0.001), and AEE corrected by body mass (r = 0.71, P < 0.001). This study showed that the Tracmor D is a highly accurate instrument for predicting free‐living energy expenditure. The miniaturized design did not harm the ability of the instrument in measuring physical activity and in determining outcome parameters of physical activity such as TEE, AEE, and PAL.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
HASKELL, W. L., LEE, I.-M., PATE, R. R., POWELL, K. E., BLAIR, S. N., FRANKLIN, B. A., MACERA, C. A., HEATH, G. W., THOMPSON, P. D., & BAUMAN, A. (2007) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3180616b27 · Cited by 4,616
Obesity and the Environment: Where Do We Go from Here?
Hill, J. O., Wyatt, H. R., Reed, G. W., & Peters, J. C. (2003) · Science · doi:10.1126/science.1079857 · Cited by 2,180
The Technology of Accelerometry-Based Activity Monitors: Current and Future
CHEN, K. Y., & BASSETT, D. R. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185571.49104.82 · Cited by 996
Physical Activity Assessment With Accelerometers: An Evaluation Against Doubly Labeled Water
Plasqui, G., & Westerterp, K. R. (2007) · Obesity · doi:10.1038/oby.2007.281 · Cited by 654
Self-citationWesterterp, K. R. (2004) · Nutrition & Metabolism · doi:10.1186/1743-7075-1-5 · Cited by 570
Self-citationBrage, S., Brage, N., Ekelund, U., Luan, J., Franks, P. W., Froberg, K., & Wareham, N. J. (2006) · European Journal of Applied Physiology · doi:10.1007/s00421-005-0112-6 · Cited by 127 · cited 2×
“Likewise, accelerometers have been coupled to heart rate monitors to increase the accuracy in the AEE estimation (7,16).”
MethodZakeri, I., Adolph, A. L., Puyau, M. R., Vohra, F. A., & Butte, N. F. (2008) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01163.2007 · Cited by 80 · cited 1×
“Likewise, accelerometers have been coupled to heart rate monitors to increase the accuracy in the AEE estimation (7,16).”
Method
Cited by
van Hees, V. T., Gorzelniak, L., Dean León, E. C., Eder, M., Pias, M., Taherian, S., Ekelund, U., Renström, F., Franks, P. W., Horsch, A., et al. (2013) · PLoS ONE · doi:10.1371/journal.pone.0061691 · Cited by 926
Practical Guide to Measuring Physical Activity
Sylvia, L. G., Bernstein, E. E., Hubbard, J. L., Keating, L., & Anderson, E. J. (2014) · Journal of the Academy of Nutrition and Dietetics · doi:10.1016/j.jand.2013.09.018 · Cited by 637
Validity of Consumer-Based Physical Activity Monitors
LEE, J.-M., KIM, Y., & WELK, G. J. (2014) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000287 · Cited by 401
“The DL (DirectLife, Philips Lifestyle Incubator, Amsterdam, The Netherlands) is a triaxial accelerometrybased monitor, based on a previously developed research device called the Tracmor (3).”
MethodDowd, K. P., Szeklicki, R., Minetto, M. A., Murphy, M. H., Polito, A., Ghigo, E., van der Ploeg, H., Ekelund, U., Maciaszek, J., Stemplewski, R., et al. (2018) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-017-0636-2 · Cited by 385
Daily physical activity assessment with accelerometers: new insights and validation studies
Plasqui, G., Bonomi, A. G., & Westerterp, K. R. (2013) · Obesity Reviews · doi:10.1111/obr.12021 · Cited by 315
Self-citationXie, J., Wen, D., Liang, L., Jia, Y., Gao, L., & Lei, J. (2018) · JMIR mHealth and uHealth · doi:10.2196/mhealth.9754 · Cited by 310
“Bonomi et al [35] predicted total energy consumption and energy consumption during activity using the output results of wearable devices and found that the output value of the device and the energy consumption value were clearly correlated.”
MethodValidity of physical activity monitors during daily life in patients with COPD
Rabinovich, R. A., Louvaris, Z., Raste, Y., Langer, D., Van Remoortel, H., Giavedoni, S., Burtin, C., Regueiro, E. M. G., Vogiatzis, I., Hopkinson, N. S., et al. (2013) · European Respiratory Journal · doi:10.1183/09031936.00134312 · Cited by 293
Self-citationvan Hees, V. T., Renström, F., Wright, A., Gradmark, A., Catt, M., Chen, K. Y., Löf, M., Bluck, L., Pomeroy, J., Wareham, N. J., et al. (2011) · PLoS ONE · doi:10.1371/journal.pone.0022922 · Cited by 289
Validity of activity monitors in health and chronic disease: a systematic review
Van Remoortel, H., Giavedoni, S., Raste, Y., Burtin, C., Louvaris, Z., Gimeno-Santos, E., Langer, D., Glendenning, A., Hopkinson, N. S., Vogiatzis, I., et al. (2012) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/1479-5868-9-84 · Cited by 277
Wijsman, C. A., Westendorp, R. G., Verhagen, E. A., Catt, M., Slagboom, P. E., de Craen, A. J., Broekhuizen, K., van Mechelen, W., van Heemst, D., van der Ouderaa, F., et al. (2013) · Journal of Medical Internet Research · doi:10.2196/jmir.2843 · Cited by 156
“The activity monitor of DirectLife is based on the Tracmor tri-axial accelerometer and has been validated against doubly labeled water for the estimation of total daily life energy expenditure [18].”
Kraal, J. J., Peek, N., Van den Akker-Van Marle, M. E., & Kemps, H. M. (2014) · European Journal of Preventive Cardiology · doi:10.1177/2047487314552606 · Cited by 116
Emerging therapies for gait disability and balance impairment: Promises and pitfalls
Maetzler, W., Nieuwhof, F., Hasmann, S. E., & Bloem, B. R. (2013) · Movement Disorders · doi:10.1002/mds.25682 · Cited by 57
Bonomi, A. G., Soenen, S., Goris, A. H. C., & Westerterp, K. R. (2013) · PLoS ONE · doi:10.1371/journal.pone.0059641 · Cited by 32
Self-citationLeptin and energy restriction induced adaptation in energy expenditure
Camps, S. G. J. A., Verhoef, S. P. M., & Westerterp, K. R. (2015) · Metabolism · doi:10.1016/j.metabol.2015.06.016 · Cited by 22
Self-citation
Metadata
- Authors
- Bonomi, A. G., Plasqui, G., Goris, A. H. C., & Westerterp, K. R.
- Venue
- Obesity
- Publisher
- Wiley
- Published
- 2010-09
- Volume
- 18
- Issue
- 9
- Pages
- 1845-1851
- ISSN
- 1930-7381 (ISSN-L)
- 1930-739X
- OpenAlex
- W1968418870
- Cited by
- 100
- References
- 7
- FWCI
- 7.61
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.