A deep learning-enabled portable imaging flow cytometer for cost-effective, high-throughput, and label-free analysis of natural water samples
Open accessThe DOI matches its Crossref record; 48 of the 48 references it cites were found in a registry or an index.
Abstract
We report a deep learning-enabled field-portable and cost-effective imaging flow cytometer that automatically captures phase-contrast color images of the contents of a continuously flowing water sample at a throughput of 100 mL/h. The device is based on partially coherent lens-free holographic microscopy and acquires the diffraction patterns of flowing micro-objects inside a microfluidic channel. These holographic diffraction patterns are reconstructed in real time using a deep learning-based phase-recovery and image-reconstruction method to produce a color image of each micro-object without the use of external labeling. Motion blur is eliminated by simultaneously illuminating the sample with red, green, and blue light-emitting diodes that are pulsed. Operated by a laptop computer, this portable device measures 15.5 cm × 15 cm × 12.5 cm, weighs 1 kg, and compared to standard imaging flow cytometers, it provides extreme reductions of cost, size and weight while also providing a high volumetric throughput over a large object size range. We demonstrated the capabilities of this device by measuring ocean samples at the Los Angeles coastline and obtaining images of its micro- and nanoplankton composition. Furthermore, we measured the concentration of a potentially toxic alga (Pseudo-nitzschia) in six public beaches in Los Angeles and achieved good agreement with measurements conducted by the California Department of Public Health. The cost-effectiveness, compactness, and simplicity of this computational platform might lead to the creation of a network of imaging flow cytometers for large-scale and continuous monitoring of the ocean microbiome, including its plankton composition.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures







Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“However, the technologies based on images are easily time-consuming, and their quality and efficiency are easily subjected to the tradeoff between resolution and visual field.”
From Simultaneously Acquiring Optical and Acoustic Properties of Individual Microalgae Cells Suspended in Water (2022) · cites this paper as [6]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Primary production of the biosphere: Integrating terrestrial and oceanic components
Field, C. B., Behrenfeld, M. J., Randerson, J. T., & Falkowski, P. (1998) · Science · doi:10.1126/science.281.5374.237 · Cited by 6,371
Phase recovery and holographic image reconstruction using deep learning in neural networks
Rivenson, Y., Zhang, Y., Günaydın, H., Teng, D., & Ozcan, A. (2017) · Light: Science & Applications · doi:10.1038/lsa.2017.141 · Cited by 1,059
Self-citationMovable Aperture Lensless Transmission Microscopy: A Novel Phase Retrieval Algorithm
Faulkner, H. M. L., & Rodenburg, J. M. (2004) · Physical Review Letters · doi:10.1103/physrevlett.93.023903 · Cited by 839
Biospheric Primary Production During an ENSO Transition
Behrenfeld, M. J., Randerson, J. T., McClain, C. R., Feldman, G. C., Los, S. O., Tucker, C. J., Falkowski, P. G., Field, C. B., Frouin, R., Esaias, W. E., et al. (2001) · Science · doi:10.1126/science.1055071 · Cited by 649
Digital in-line holography for biological applications
Xu, W., Jericho, M. H., Meinertzhagen, I. A., & Kreuzer, H. J. (2001) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.191361398 · Cited by 576
Phase-retrieval stagnation problems and solutions
Fienup, J. R., & Wackerman, C. C. (1986) · Journal of the Optical Society of America A · doi:10.1364/josaa.3.001897 · Cited by 538
Gobler, C. J., Doherty, O. M., Hattenrath-Lehmann, T. K., Griffith, A. W., Kang, Y., & Litaker, R. W. (2017) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1619575114 · Cited by 537
A submersible imaging‐in‐flow instrument to analyze nano‐and microplankton: Imaging FlowCytobot
Olson, R. J., & Sosik, H. M. (2007) · Limnology and Oceanography: Methods · doi:10.4319/lom.2007.5.195 · Cited by 472
Chaos in a long-term experiment with a plankton community
Benincà, E., Huisman, J., Heerkloss, R., Jöhnk, K. D., Branco, P., Van Nes, E. H., Scheffer, M., & Ellner, S. P. (2008) · Nature · doi:10.1038/nature06512 · Cited by 455
Lensfree on-chip microscopy over a wide field-of-view using pixel super-resolution
Bishara, W., Su, T.-W., Coskun, A. F., & Ozcan, A. (2010) · Optics Express · doi:10.1364/oe.18.011181 · Cited by 440
Cited by
Items 101–190 of 190
Automated cell profiling in imaging flow cytometry with annotation-efficient learning
Hong, T., Peng, M., Kim, Y., Schellhorn, H. E., & Fang, Q. (2024) · Optics & Laser Technology · doi:10.1016/j.optlastec.2024.111992 · Cited by 8
Artificial Intelligence-Assisted Microfluidic Bio-Imaging—From Sensors to Applications: A Review
Chen, J., Fu, L. P., Xiang, R., Luo, S., Huang, X., Yu, H., & Sun, L. (2024) · IEEE Sensors Journal · doi:10.1109/jsen.2024.3507081 · Cited by 9
“Göröcs et al. [117] developed a cost-effective, portable lens-free color in-line holographic imaging flow cytometer housed in a 15.5 × 15 × 12.5 cm enclosure with good imaging performance on plankton-containing marine samples, the schematic of the flow cytometer is shown in Fig.”
InfluentialGiugliano, G., Pirone, D., Běhal, J., Wang, Z., Cerbone, V., Mugnano, M., Licitra, F., Montella, A., Scalia, G., Capasso, M., et al. (2024) · Journal of the Optical Society of America A · doi:10.1364/josaa.536841 · Cited by 7
Self-citationBianco, V., Memmolo, P., Merola, F., Carcagnì, P., Distante, C., & Ferraro, P. (2019) · Quantitative Phase Imaging · doi:10.1117/12.2509515 · Cited by 7
Self-citationCharacterization Method for Particle Extraction From Raw-Reconstructed Images Using U-Net
Hao, Z., Li, W.-N., Hou, B., Su, P., & Ma, J. (2022) · Frontiers in Physics · doi:10.3389/fphy.2021.816158 · Cited by 8
A fractal analysis of the holographic diffraction patterns for detecting microplastics among diatoms
Pirone, D., Bianco, V., Memmolo, P., Merola, F., & Ferraro, P. (2021) · IEEE International Workshop on Metrology for the Sea; Learning to Measure Sea Health Parameters (MetroSea) · doi:10.1109/metrosea52177.2021.9611578 · Cited by 7
“DH has also been exploited for the environmental monitoring [13-16].”
BackgroundSelf-citationCabrol, L., Delleuze, M., Szylit, A., Schwob, G., Quéméneur, M., & Misson, B. (2023) · Marine Pollution Bulletin · doi:10.1016/j.marpolbul.2023.115688 · Cited by 7
3D imaging in microfluidics: new holographic methods and devices
Bianco, V., Miccio, L., Memmolo, P., Merola, F., Mandracchia, B., Cacace, T., Mugnano, M., Paturzo, M., Villone, M. M., Maffettone, P. L., et al. (2019) · Microfluidics, BioMEMS, and Medical Microsystems · doi:10.1117/12.2509581 · Cited by 6
“without the need for computationally demanding phase retrieval approaches [25].”
BackgroundSelf-citationApplicability of flow imaging microscopy (FlowCAM) as a ballast water investigation tool
Chen, Y., Wang, Q., Xue, J., Yang, Y., & Wu, H. (2023) · Regional Studies in Marine Science · doi:10.1016/j.rsma.2023.102821 · Cited by 8
Automated lightless cytometry on a microchip with adaptive immunomagnetic manipulation
Civelekoglu, O., Wang, N., Arifuzzman, A. K. M., Boya, M., & Sarioglu, A. F. (2022) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2022.114014 · Cited by 6
Pacheco, C., McKay, G. N., Oommen, A., Durr, N. J., Vidal, R., & Haeffele, B. D. (2022) · Optics Express · doi:10.1364/oe.458360 · Cited by 6
Picazo-Bueno, J. Á., Sanz, M., Granero, L., García, J., & Micó, V. (2023) · Sensors · doi:10.3390/s23031472 · Cited by 9
“In addition, other future biomedical applications could be developed, for instance, for the combination of MISHELF microscopy with microfluidics to allow imaging flow cytometry [105,106] or to combine the technique with deep learning-assisted techniques [86,107,108] for the diagnosis of cancer and diseases [23–25,78,1…”
MethodSu, D., Li, X., Gao, W., Wei, Q., Li, H., Guo, C., & Zhao, W. (2023) · Opto-Electronic Science · doi:10.29026/oes.2023.230018 · Cited by 6
Montandon, F., & Nicolls, F. (2024) · Advanced Intelligent Systems · doi:10.1002/aisy.202400235 · Cited by 6
Taheriashtiani, N., Ge, Z., Harandi, M. T., Crosbie, N. D., McGregor, G. B., Gao, L., Chen, C., Blackall, L. L., Burch, M. D., Lintern, A. M., et al. (2026) · Algal Research · doi:10.1016/j.algal.2026.104599 · Cited by 7
Off-axis digital lensless holographic microscopy based on spatially multiplexed interferometry
Picazo-Bueno, J. Á., Ketelhut, S., Schnekenburger, J., Micó, V., & Kemper, B. (2024) · Journal of Biomedical Optics · doi:10.1117/1.jbo.29.s2.s22715 · Cited by 9
Rapid structure sensing of suspended particles in water using particulate Mueller matrix polarimetry
Lei, J., Li, J., Liu, H., Xiong, Z., Jiang, F., Han, B., Yang, J., & Liao, R. (2025) · Measurement · doi:10.1016/j.measurement.2025.116754 · Cited by 5
Dual-Modality Imaging Microfluidic Cytometer for Onsite Detection of Phytoplankton
Xiong, B., Hong, T., Schellhorn, H. E., & Fang, Q. (2021) · Photonics · doi:10.3390/photonics8100435 · Cited by 5
“Recently, lensless imaging has been used for morphological observation of particles/cells in the fluidic samples, such as characterization of microplastics [27], urine analysis [28,29], blood analysis [30], and phytoplankton analysis [31].”
MethodChen, Y., Wang, H., Liao, R., Li, H., Wang, Y., Zhou, H., Li, J., Huang, T., Zhang, X., & Ma, H. (2022) · Biosensors · doi:10.3390/bios12050321 · Cited by 5
Wang, Y., Zhang, Y., Wang, J., Liu, W., Wang, H., Song, M., Zhang, H., & Wang, X. (2024) · Ecotoxicology and Environmental Safety · doi:10.1016/j.ecoenv.2023.115894 · Cited by 5
Hughes, M. R., & McCall, C. (2024) · Biomedical Optics Express · doi:10.1364/boe.516030 · Cited by 5
“However, it has the advantages of being simple, low-cost and robust, with potential applications in fields such as diagnostic imaging [4] and water sample monitoring [5].”
BackgroundCarvalho, D. A. M., Pinto, V. C., Sousa, P. J., Magalhães, V. H., Fernández, E., Gomes, P., Minas, G. M. H., & Gonçalves, L. M. (2022) · Applied Sciences · doi:10.3390/app12115376 · Cited by 5
Complete holography‐based system for the identification of microparticles in water samples
Silva, A., Distante, C., & Gonçalves, L. M. G. (2023) · Journal of Microscopy · doi:10.1111/jmi.13249 · Cited by 5
“35 According to this prior report, these portable devices, when compared with imaging flow cytometers, provide extreme reductions in cost, size and weight while also providing a high volumetric throughput over a large object size range.”
BackgroundOptical Spectroscopy for on Line Water Monitoring
Testa, G., Persichetti, G., & Bernini, R. (2022) · Springer water · doi:10.1007/978-3-031-08262-7_8 · Cited by 4
Unlocking the algae toolbox: Cutting-edge tools for environmental and biotechnological solutions
Bui, V. K. H., Trung, L. G., Huu, H., Tran, N. T., & Nguyen, M. K. (2025) · Biotechnology Advances · doi:10.1016/j.biotechadv.2025.108652 · Cited by 5
Deep focus-extended darkfield imaging for in situ observation of marine plankton
Chen, T., Li, J., Ma, W., Guo, G., Yang, Z., Li, Z., & Qiao, J. (2023) · Frontiers in Marine Science · doi:10.3389/fmars.2023.1074428 · Cited by 6
“Imaging flow cytometers actively pump seawater into their instruments and implement microscopy (mainly on microphytoplankton) as the seawater is flowing through an interrogation volume to improve the sampling rate (Olson and Sosik, 2007; Grcs et al., 2018).”
BackgroundBianco, V., Memmolo, P., Merola, F., Carcagnì, P., Paturzo, M., Distante, C., & Ferraro, P. (2019) · Optical Methods for Inspection, Characterization, and Imaging of Biomaterials · doi:10.1117/12.2527496 · Cited by 5
“Moreover, several configurations have been proposed to deploy DH technology on the field in the form of high-throughput lensless imaging flow cytometers, or even submersible holographic cameras [16,17].”
BackgroundSelf-citationBianco, V., Memmolo, P., Carcagnì, P., Merola, F., Paturzo, M., Distante, C., & Ferraro, P. (2019) · Digital Holography and Three-Dimensional Imaging · doi:10.1364/dh.2019.th2a.2 · Cited by 4
Self-citationMeasurement of specular surfaces using electrically tunable lens in digital holography
Barak, N., Kumari, V., & Sheoran, G. (2022) · Journal of Optics · doi:10.1088/2040-8986/ac9b73 · Cited by 4
“This technique, called digital holographic microscopy, has also been largely utilized to find the surface profiles of specular [22, 23] and diffusely reflecting objects [24–27].”
Machine learning is a powerful tool to study the effect of cancer on species and ecosystems
Dujon, A. M., Vittecoq, M., Bramwell, G., Thomas, F., & Újvári, B. (2021) · Methods in Ecology and Evolution · doi:10.1111/2041-210x.13703 · Cited by 4
On-chip light scattering imaging of the guanine platelet
Iwasaka, M. (2021) · Japanese Journal of Applied Physics · doi:10.35848/1347-4065/ac439b · Cited by 4
Initial Deployment of a Mobile Sensing System for Water Quality in Urban Canals
Meyers, D., Zheng, Q., Duarte, F., Ratti, C., Hemond, H. F., van der Blom, M., van der Helm, A. W. C., & Whittle, A. J. (2022) · Water · doi:10.3390/w14182834 · Cited by 3
High-resolution portable lens-free on-chip microscopy with RGB LED via pinhole array
Wang, Q., Ma, J., Cao, L., & Su, P. (2024) · Chinese Optics Letters · doi:10.3788/col202422.021101 · Cited by 3
Ferrara, M. A., Cavalletti, E., Bianco, V., Miccio, L., Coppola, G., Ferraro, P., & Sardo, A. (2025) · PLoS ONE · doi:10.1371/journal.pone.0322960 · Cited by 3
“The spatial and temporal patterns of Pseudo-nitzschia , a toxic alga producing domoic acid, have been reported to guide fishery activities and foster public health [22].”
Self-citationRarima, R., & Veerasingam, S. (2025) · Optics & Laser Technology · doi:10.1016/j.optlastec.2025.113402 · Cited by 3
Julian, T., Tang, T., Tanga, N., Yang, Y., Hosokawa, Y., & Yalikun, Y. (2025) · Lab on a Chip · doi:10.1039/d5lc00673b · Cited by 3
Işıl, Ç., Haan, K. D., Gӧrӧcs, Z., Koydemir, H. C., Peterman, S., Baum, D., Fang, S., Skandakumar, T., Gumustekin, E., & Özcan, A. (2021) · Frontiers in Optics · doi:10.1364/fio.2021.fm3d.4 · Cited by 3
Self-citationPhytoplankton diversity and chemotaxonomy in contrasting North Pacific ecosystems
Matek, A., Bosak, S., Šupraha, L., Neeley, A., Višić, H., Cetinić, I., & Ljubešić, Z. (2023) · PeerJ · doi:10.7717/peerj.14501 · Cited by 5
“Recent advances in molecular and imaging technologies offer an unprecedented view of the oceanic diversty (Gorocs et al., 2018; Shin et al., 2018; Fender et al., 2019; Hoving et al., 2019; Fischer et al., 2020; Mirasbekov et al., 2021; Clayton et al., 2022).”
BackgroundDigital holography for real-time non-invasive monitoring of larval fish at power plant intakes
Sanborn, D., Base, A., Garavelli, L., Barua, R., Hong, J., & Nayak, A. R. (2023) · Canadian Journal of Fisheries and Aquatic Sciences · doi:10.1139/cjfas-2023-0058 · Cited by 3
Tian, D., Yu, N., Li, Z., Li, S., & Li, N. (2020) · PLoS ONE · doi:10.1371/journal.pone.0235111 · Cited by 3
“Furthermore, the resolution and the flow rate of solution can be improved by using image sensors with smaller pixels and higher sampling rates, or using the high-throughput microfluidic chips of the multi-channel, and high-throughput analysis can be achieved in the paper [21].”
BackgroundAdvances in Microfluidics for the Implementation of Liquid Biopsy in Clinical Routine
Teixeira, A., Carneiro, A., Piairo, P., Xavier, M., Ainla, A., Lopes, C., Sousa-Silva, M., Dias, A., Martins, A. S., Rodrigues, C., et al. (2022) · Advances in experimental medicine and biology · doi:10.1007/978-3-031-04039-9_22 · Cited by 4
Automatic multifocusing in digital holographic microscopy
Terbe, D., Orzo, L. R., & Zarándy, Á. (2026) · Optics Express · doi:10.1364/oe.586494 · Cited by 2
Pirone, D., Verde, G. L., Běhal, J., Arrichiello, C., Muto, P., Kurelac, I., Bagnale, L., Sirico, D. G., Medugno, M., del Giudice, D., et al. (2024) · Journal of Physics D Applied Physics · doi:10.1088/1361-6463/ad7c56 · Cited by 3
Self-citationPopescu, G. (2019) · Light Science & Applications · doi:10.1038/s41377-019-0133-2 · Cited by 2
Ivetich, S. D., Stavrakis, S., & deMello, A. J. (2024) · AAPS introductions in the pharmaceutical sciences · doi:10.1007/978-3-031-60717-2_9 · Cited by 1
Taheriashtiani, N., Lin, T., Burch, M. D., Lintern, A. M., & Zamyadi, A. (2026) · ACS ES&T Water · doi:10.1021/acsestwater.6c00058 · Cited by 2
Shrihari, A., Guha, P., & Kulkarni, R. D. (2025) · Journal of the Optical Society of America A · doi:10.1364/josaa.545760 · Cited by 2
Detection and remediation of harmful algal blooms: Opportunities for electrochemists?
Atkinson, W. S., Saju, C., & Yang, M. (2025) · Current Opinion in Electrochemistry · doi:10.1016/j.coelec.2025.101711 · Cited by 1
Recent Trends in Computational Optical Phase Imaging
Liu, C., Wang, S., & Veetil, S. P. (2022) · Progress in optical science and photonics · doi:10.1007/978-981-19-1641-0_6 · Cited by 1
Artificial Intelligence in Phycochemicals Recognition
Dullius, A., Buffon, G., Faria, M., & Giuliatti, S. (2023) · Springer eBooks · doi:10.1007/978-3-031-42026-9_5 · Cited by 2
人工智能定量相位成像:从物理到算法再到物理(内封面文章·特邀)
Xuan, 田. T., Shuquan, 费. F., Runze, 李. L., Tong, 彭. P., Junwei, 闵. M., Siying, 王. W., Yuge, 薛. X., Chen, 柏. B., & Yao, B. (2025) · Infrared and Laser Engineering · doi:10.3788/irla20240490 · Cited by 1
Survey, monitoring and assessment of marine communities conducted by new technology
Yamamoto, H. (2020) · BUTSURI-TANSA(Geophysical Exploration) · doi:10.3124/segj.73.53 · Cited by 2
Compact portable holographic microscope for cell and particle counting in microfuidics
da Silva, A. G. J., Cacace, T., Bianco, V., Paturzo, M., Gonçalves, L. M. G., Carcagnì, P., Distante, C., & Ferraro, P. (2020) · Imaging and Applied Optics · doi:10.1364/dh.2020.hw4c.5 · Cited by 1
Self-citationHolographic fingerprint as a morphological marker to identify micro-plastics
Bianco, V., Memmolo, P., Pirone, D., Carcagnì, P., Merola, F., Miccio, L., Paturzo, M., Distante, C., & Ferraro, P. (2021) · Optical Measurement Systems for Industrial Inspection XI · doi:10.1117/12.2593832 · Cited by 1
“Recently, digital holography (DH) has been demonstrated as a very powerful tool for MPs imaging [4], ensuring unique capabilities such as label-free 3D imaging, flexible focusing of samples in microfluidic streams, high throughput and the possibility to implement low-cost field-portable systems for in situ environment…”
Self-citationPortable Imaging Flow cytometer Using Deep Learning based Holographic Image Reconstruction
Gӧrӧcs, Z., Tamamitsu, M., Bianco, V., Wolf, P., Roy, S., Shindo, K., Yanny, K., Wu, Y., Koydemir, H. C., Rivenson, Y., et al. (2019) · Conference on Lasers and Electro-Optics · doi:10.1364/cleo_si.2019.sm4h.2 · Cited by 1
Self-citationThe use of an automated organism tracking microscope in mesocosm experiments
Blackburn, N. D., Haecky, P., Jurgensone, I., Grinienė, E., Brugel, S., Andersson, A., & Carstensen, J. (2022) · Limnology and Oceanography Methods · doi:10.1002/lom3.10521 · Cited by 1
Light People: Professor Aydogan Ozcan
Sun, T. (2021) · Light Science & Applications · doi:10.1038/s41377-021-00643-1 · Cited by 1
D’Almeida, C. D. P. (2023) · doi:10.11606/t.76.2023.tde-29052023-143103 · Cited by 1
Gu, B.-Y., Li, Z.-Y., & Yang, G.-Z. (1998) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.302392
Compact modules for off-axis holography in microfluidics: features and design solutions
Bianco, V., Cacace, T., Mandracchia, B., Pagliarulo, V., Paturzo, M., & Ferraro, P. (2019) · Optics and Biophotonics in Low-Resource Settings · doi:10.1117/12.2509527
Self-citationHigh accuracy platelet counting using lensfree imaging
Isèbe, D., Gremion, E., Daynès, A., Thouy, B., Rongeat, N., Bressieux, S., Ali‐Cherif, A., Rebuffel, V., Joly, P., Morales, S., et al. (2019) · Novel Biophotonics Techniques and Applications · doi:10.1117/12.2527008
“Lensfree is applied by many groups to address different problematics [2-4].”
BackgroundField-deployable, cost-effective holographic slide microscope: a 3D-printed prototype
Bianco, V., Cacace, T., Mandracchia, B., Pagliarulo, V., Oleandro, E., Paturzo, M., & Ferraro, P. (2020) · Imaging and Applied Optics · doi:10.1364/dh.2020.hw3c.2
Self-citationLabel-free microfluidic platform for blood analysis based on phase-contrast imaging
Miccio, L., Cimmino, F., Kurelac, I., Villone, M. M., Bianco, V., Mugnano, M., Merola, F., Memmolo, P., Pirone, D., Capasso, M., et al. (2021) · IEEE International Workshop on Metrology for AeroSpace (MetroAeroSpace) · doi:10.1109/metroaerospace51421.2021.9511700
Self-citationDesign of Project Cost Management System Based on Computer Technology
Yan, T. (2022) · Lecture notes in electrical engineering · doi:10.1007/978-981-16-4258-6_92
LED-Based Optical Sensing Platforms for Multi-Analyte Detection
Shin, Y.-H. (2021) · Louisiana State University · doi:10.31390/gradschool_dissertations.5508
Point spread function engineering based on wavefront phase modulation
Zhang, W.-Q., Cui, X., Yue, J., Ren, L., Cheng, X., & Hao, Q. (2023) · Optoelectronic Imaging and Multimedia Technology · doi:10.1117/12.2686463
“Monitoring methods for plankton include flow cytometry 161, 162 , acoustic monitoring 163 and optical monitoring 164, 165 .”
MethodCompact Label-free Microfluidic System for Single Cell Imaging and Diagnosis
Wang, Z., Villone, M. M., Maffettone, P. L., Valentino, M., Marí, S. M., Miccio, L., Běhal, J., & Ferranti, F. (2024) · IEEE International Workshop on Metrology for AeroSpace (MetroAeroSpace) · doi:10.1109/metroaerospace61015.2024.10591566
“Noteworthy, it has been demonstrated that QPI systems can be scaled-down for point-of-care diagnostics [3].”
BackgroundGiugliano, G., Miccio, L., Bianco, V., Pirone, D., Memmolo, P., & Ferraro, P. (2024) · Digital Holography and Three-Dimensional Imaging · doi:10.1364/dh.2024.th2a.3
Self-citation3D Visualization of Phytoplankton via In-Flow Digital Holographic Tomography
Borrelli, F., Giugliano, G., Pirone, D., Běhal, J., Zupo, V., Amoroso, M., Costantini, M., Sardo, A., Miccio, L., Memmolo, P., et al. (2024) · Digital Holography and Three-Dimensional Imaging · doi:10.1364/dh.2024.w4a.19
Self-citationControl of biological contamination in microalgae cultures
Flores-Tinoco, V., Brito-Bello, A. A., Le, V. P., & López-Arredondo, D. L. (2024) · Elsevier eBooks · doi:10.1016/b978-0-443-14058-7.00005-1 · Cited by 1
Investigation of Marine Phytoplankton by In-Flow Holographic Tomography
Borrelli, F., Giugliano, G., Běhal, J., Pirone, D., Roselli, L., Sardo, A., Houliez, E., Zupo, V., Costantini, M., Miccio, L., et al. (2024) · IEEE International Workshop on Metrology for the Sea; Learning to Measure Sea Health Parameters (MetroSea) · doi:10.1109/metrosea62823.2024.10765697
“This allowed new investigation possibilities regarding phytoplankton characterization and in situ monitoring of algal blooms [14] and microplastics identification [15].”
Self-citationHong, T., Peng, M. R., & Fang, Q. (2025) · Elsevier eBooks · doi:10.1016/b978-0-323-95478-5.00024-8
Xiao, Y., Zeng, Q., Liu, L., & Sun, X. (2025) · Sixth Symposium on Novel Optoelectronic Detection Technology and Applications · doi:10.1117/12.3057181
Lippeveld, M., Peralta, D., Vardi, A., Vincent, F., & Saeys, Y. (2025) · Cytometry Part A · doi:10.1002/cyto.a.24944
MacNeil, L., Missan, S., Luo, J., Trappenberg, T. P., & LaRoche, J. (2021) · Figshare · doi:10.6084/m9.figshare.14795399
Xu, M., Gaofang, Y., Renqing, 贾. J., Yun, P., Wang, X., Liang, T., Hu, X., Huang, P., Zhang, M., Zhu, C., et al. (2026) · Applied Optics · doi:10.1364/ao.590392
Flasseur, O. (2019) · theses.fr (ABES) · doi:10.70675/c8768be8z788ez4e60za3c9zaa2df8224053 · Cited by 1
Machine Learning on High-Throughput Bioparticles Image Recognition and Sizing
Luo, S. (2021) · theses.fr (ABES) · doi:10.70675/a9a9d1ffzfc5cz452fz979bz191c257b5077
Khokher, S., Jhanjhriya, N., Thakran, M., Pahuja, P., & Lata, S. (2026) · Materials and Corrosion · doi:10.1002/maco.70190
Jianping, 李. L., Liangpei, 陈. C., Kaijian, 郑. Z., Jingyao, G., Zhenping, 李. L., Min, 姚. Y., Boxue, 王. W., Abbas, A. N., Zhisheng, 周. Z., Peng, 吕. L., et al. (2026) · Acta Optica Sinica · doi:10.3788/aos260849
Liu, W., Tang, Q., Shen, M., Zhang, L., & Jia, X. (2026) · Applied Microbiology and Biotechnology · doi:10.1007/s00253-026-13917-8
High-throughput sorting of Chlamydomonas reinhardtii by complex mitochondrial morphology
HARMON, J. O. (2022) · Institutional Repositories DataBase (IRDB) · doi:10.15083/0002010918
Fu, L., Chen, J., Zhang, Y., Wang, Z., & Huang, X. (2026) · Analytica Chimica Acta · doi:10.1016/j.aca.2026.346347
Zheng, S., Zhou, Z., Zhao, C., & Li, J. (2026) · Optics Express · doi:10.1364/oe.605446
Dynamic Diagnosis and Integrated Intelligent Management of Urban Drainage Ecological Risks
Wang, A., Cui, H., Jiang, J., Xiao, P., Pang, Z., Ren, Y., Meng, W., Tao, Y., & Liang, B. (2026) · Water & Ecology · doi:10.1016/j.wateco.2026.100058
Metadata
- Authors
- Gӧrӧcs, Z., Tamamitsu, M., Bianco, V., Wolf, P., Roy, S., Shindo, K., Yanny, K., Wu, Y., Koydemir, H. C., Rivenson, Y., & Ozcan, A.
- Affiliations
- California NanoSystems Institute (US)
- University of California, Los Angeles (US)
- ORCID
- Venue
- Light: Science & Applications
- Published
- 2018-09-19
- Volume
- 7
- Issue
- 1
- Pages
- 66-66
- ISSN
- 2047-7538 (ISSN-L)
- PMC
- PMC6143550
- OpenAlex
- W2889672357
- Cited by
- 188
- References
- 48
- Citations by year
- 2026: 9 · 2025: 16 · 2024: 18 · 2023: 32 · 2022: 31 · 2021: 30 · 2020: 23 · 2019: 25 · 2018: 3
- FWCI
- 9.37
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/4.0 (tdm)
- creativecommons.org/licenses/by/4.0 (vor)
- Locations
- Light Science & Applications (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, other-oa)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
- Funders
- National Science Foundation
- Howard Hughes Medical Institute
- Mary Kay Foundation
- California Department of Public Health
- Engineering Research Centers
- National Institutes of Health
- National Institute of General Medical Sciences (R25GM055052)
- Division of Chemical, Bioengineering, Environmental, and Transport Systems
- Division of Emerging Frontiers in Research and Innovation
- Division of Emerging Frontiers
- Army Research Office
- Life Sciences Division, Army Research Office
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Digital Holography and Microscopy
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Random lasers and scattering media
- Physical Sciences › Engineering › Media Technology › Advanced Optical Imaging Technologies
- Keywords
- imaging flow cytometry, phase recovery, microfluidic channels, portable field instrument, low-cost instrumentation, plankton composition, Pseudo-nitzschia, harmful algal bloom monitoring, natural water samples, diffraction pattern reconstruction
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.