Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 52 of the 52 references it cites were found in a registry or an index.

Raman lasing and soliton mode-locking in lithium niobate microresonators

Open access

Abstract

The recent advancement in lithium-niobite-on-insulator (LNOI) technology is opening up new opportunities in optoelectronics, as devices with better performance, lower power consumption and a smaller footprint can be realised due to the high optical confinement in the structures. The LNOI platform offers both large χ(2) and χ(3) nonlinearities along with the power of dispersion engineering, enabling brand new nonlinear photonic devices and applications for the next generation of integrated photonic circuits. However, Raman scattering and its interaction with other nonlinear processes have not been extensively studied in dispersion-engineered LNOI nanodevices. In this work, we characterise the Raman radiation spectra in a monolithic lithium niobate (LN) microresonator via selective excitation of Raman-active phonon modes. The dominant mode for the Raman oscillation is observed in the backward direction for a continuous-wave pump threshold power of 20 mW with a high differential quantum efficiency of 46%. We explore the effects of Raman scattering on Kerr optical frequency comb generation. We achieve mode-locked states in an X-cut LNOI chip through sufficient suppression of the Raman effect via cavity geometry control. Our analysis of the Raman effect provides guidance for the development of future chip-based photonic devices on the LNOI platform.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41377-020-0246-7

Cites

52 of 52 references verified0 citation errors · 0 not checkable

Statistics

Figures

Fig. 1 Experimental setup. a Schematic of the LN crystalline structure. The crystal axis is along the z-axis. b, c Orientation of the LN microresonator on an X-cut wafer. A 30-GHz free spectral range (FSR) racetrack resonator is used for the Raman characterisation. b A 250-GHz FSR microring resonator is used for the Raman–Kerr interactions. c The TE and TM polarisations are also indicated. d Setup for the forward (FW) and backward (BWD) Raman characterisation. EDFA erbium-doped fibre amplifier, BPF bandpass filter, FPC fibre polarisation controller, OSA optical spectrum analyser.
Fig. 1 Experimental setup. a Schematic of the LN crystalline structure. The crystal axis is along the z-axis. b, c Orientation of the LN microresonator on an X-cut wafer. A 30-GHz free spectral range (FSR) racetrack resonator is used for the Raman characterisation. b A 250-GHz FSR microring resonator is used for the Raman–Kerr interactions. c The TE and TM polarisations are also indicated. d Setup for the forward (FW) and backward (BWD) Raman characterisation. EDFA erbium-doped fibre amplifier, BPF bandpass filter, FPC fibre polarisation controller, OSA optical spectrum analyser.CC BY · PubMed Central
Fig. 2 Raman emission for TE-polarised light from an X-cut LN racetrack microresonator. a Three Raman spectra (from top to bottom) at pump powers of 20, 200, and 400 mW, which correspond to the threshold power for the Raman oscillation with frequency shifts of 250 cm−1, 628 cm−1, and 875 cm−1, respectively. The Stokes and pump are TE-polarised and are along the LN polar z-axis. Both the forward (blue) and backward (red) spectra are shown. The cascaded Raman peak from the 1st Stokes field is also observed at 1691 nm. b Raman emission power (top to bottom: 1st to 3rd Stokes) as a function of the pump power. The threshold for the 1st Stokes peak in the backward direction is 20 mW with a high differential conversion efficiency of 46% (linear fit shown with the black dashed line). The deviation from linear growth above a pump power of 60 mW is due to mini-comb formation and other Raman oscillations.
Fig. 2 Raman emission for TE-polarised light from an X-cut LN racetrack microresonator. a Three Raman spectra (from top to bottom) at pump powers of 20, 200, and 400 mW, which correspond to the threshold power for the Raman oscillation with frequency shifts of 250 cm−1, 628 cm−1, and 875 cm−1, respectively. The Stokes and pump are TE-polarised and are along the LN polar z-axis. Both the forward (blue) and backward (red) spectra are shown. The cascaded Raman peak from the 1st Stokes field is also observed at 1691 nm. b Raman emission power (top to bottom: 1st to 3rd Stokes) as a function of the pump power. The threshold for the 1st Stokes peak in the backward direction is 20 mW with a high differential conversion efficiency of 46% (linear fit shown with the black dashed line). The deviation from linear growth above a pump power of 60 mW is due to mini-comb formation and other Raman oscillations.CC BY · PubMed Central
Fig. 3 Raman emission for the TM mode (the light polarisation is along the x-axis) at a frequency shift of 238 cm−1 at the threshold power of 340 mW.
Fig. 3 Raman emission for the TM mode (the light polarisation is along the x-axis) at a frequency shift of 238 cm−1 at the threshold power of 340 mW.CC BY · PubMed Central
Fig. 4 Kerr frequency comb generation for TE-polarised light. a Raman and Kerr oscillations for the TE mode from an LN microresonator as the pump laser is tuned into the cavity resonance (top to bottom). b RF spectrum corresponding to the bottom spectra in a.
Fig. 4 Kerr frequency comb generation for TE-polarised light. a Raman and Kerr oscillations for the TE mode from an LN microresonator as the pump laser is tuned into the cavity resonance (top to bottom). b RF spectrum corresponding to the bottom spectra in a.CC BY · PubMed Central
Fig. 5 Kerr frequency comb generation for TM-polarised light. a Kerr oscillation for the TM mode from an X-cut LN microresonator as the pump laser is red-detuned into the cavity resonance (top to bottom). b RF spectra corresponding to States (ii) and (iii) in a. c Transmission measurement of the microresonator output above 1570 nm, which excludes the pump wavelength. The laser is tuned to the resonance as the wavelength increases, dominated by the thermal-optic effect. The laser sweeping speed is 80 pm/ms. d Zoom-in of the transmission trace in c, which shows the onset of the soliton step.
Fig. 5 Kerr frequency comb generation for TM-polarised light. a Kerr oscillation for the TM mode from an X-cut LN microresonator as the pump laser is red-detuned into the cavity resonance (top to bottom). b RF spectra corresponding to States (ii) and (iii) in a. c Transmission measurement of the microresonator output above 1570 nm, which excludes the pump wavelength. The laser is tuned to the resonance as the wavelength increases, dominated by the thermal-optic effect. The laser sweeping speed is 80 pm/ms. d Zoom-in of the transmission trace in c, which shows the onset of the soliton step.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 51 references

Research works printed but not linked: 1

  1. Boyd, R. W. Nonlinear Optics. 3rd edn. (Academic Press, Inc, Orlando, FL, USA, Academic Press, Inc, 2008).

Cited by

See all 152

Metadata

Authors
Yu, M., Okawachi, Y., Cheng, R., Wang, C., Zhang, M., Gaeta, A. L., & Lončar, M.
Affiliations
  • Harvard University (US)
  • Columbia University (US)
  • City University of Hong Kong (HK)
Corresponding author
Lončar, Marko
Venue
Light: Science & Applications
Published
2020-01-20
Volume
9
Issue
1
Pages
9-9
ISSN
2047-7538 (ISSN-L)
OpenAlex
W3000981500
Cited by
149
References
51
Citations by year
2026: 9 · 2025: 26 · 2024: 26 · 2023: 26 · 2022: 22 · 2021: 23 · 2020: 16
FWCI
8.85
Type
journal article
Language
en
Open access
Licence
Locations
  • Light Science & Applications (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • arXiv (Cornell University) (submittedVersion)
  • CityU Scholars (submittedVersion, cc-by)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
  • Figshare (submittedVersion, cc-by)
  • arXiv (Cornell University)
Funders
  • National Science Foundation (1541959, E2CDA, 1740296)
  • Harvard University (1541959)
  • Defense Advanced Research Projects Agency (1541959, W31P4Q-15-1-0013, W31P4Q)
  • Advanced Research Projects Agency
  • Division of Electrical, Communications and Cyber Systems (1541959)
  • Air Force Office of Scientific Research (FA9550-, FA9550‐15‐1‐0303, 1541959, -15-1-)
Topics
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Fiber Laser Technologies
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Photorefractive and Nonlinear Optics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Photonic and Optical Devices
Keywords
Raman lasing, soliton mode-locking, lithium niobate on insulator, Raman scattering, Kerr optical frequency combs, dispersion engineering, backward Raman scattering, differential quantum efficiency, integrated photonics, nonlinear optics

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Raman lasing and soliton mode-locking in lithium niobate microresonators. https://app.cochat.ai/papers/10.1038/s41377-020-0246-7
The paper
Yu, M., Okawachi, Y., Cheng, R., Wang, C., Zhang, M., Gaeta, A. L., & Lončar, M. (2020). Raman lasing and soliton mode-locking in lithium niobate microresonators. Light: Science & Applications. https://doi.org/10.1038/s41377-020-0246-7

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.