CoChat

Metasurface-enabled polarization-independent LCoS spatial light modulator for 4K resolution and beyond

Open access

The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.

Abstract

With the distinct advantages of high resolution, small pixel size, and multi-level pure phase modulation, liquid crystal on silicon (LCoS) devices afford precise and reconfigurable spatial light modulation that enables versatile applications ranging from micro-displays to optical communications. However, LCoS devices suffer from a long-standing problem of polarization-dependent response in that they only perform phase modulation on one linear polarization of light, and polarization-independent phase modulation—essential for most applications—have had to use complicated polarization-diversity optics. We propose and demonstrate, for the first time, an LCoS device that directly achieves high-performance polarization-independent phase modulation at telecommunication wavelengths with 4K resolution and beyond by embedding a polarization-rotating metasurface between the LCoS backplane and the liquid crystal phase-modulating layer. We verify the device with a number of typical polarization-independent application functions including beam steering, holographical display, and in a key optical switching element - wavelength selective switch (WSS), demonstrating the significant benefits in terms of both configuration simplification and performance improvement.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41377-023-01202-6

Cites

36 of 36 references verified0 citation errors · 0 not checkable

Statistics

Figures

Fig. 1 Principle and design of the LCoS device with polarization-independent phase modulation. a Schematic of the metasurface-embedded 4 K LCoS device. b Top view of the device to indicate the necessary relative orientation angle θ = 45° between nanoantenna arrays and LC molecules. c The unit cell of the designed Au-insulator-Al (MIM) structure consists of the original LCoS backplane aluminum mirror, passivation layers (H1 = 75 nm SiO2, H2 = 75 nm SiNx), a gold nanoantenna and a SiO2 cladding layer. The geometric parameters of the nanoantenna and cladding layer are optimized as follows: L = 390 nm, S = 130 nm, H = 70 nm for the nanoantennae, and HC = 320 nm for the cladding layer. The unit cells form a square lattice with a period of P = 600 nm
Fig. 1 Principle and design of the LCoS device with polarization-independent phase modulation. a Schematic of the metasurface-embedded 4 K LCoS device. b Top view of the device to indicate the necessary relative orientation angle θ = 45° between nanoantenna arrays and LC molecules. c The unit cell of the designed Au-insulator-Al (MIM) structure consists of the original LCoS backplane aluminum mirror, passivation layers (H1 = 75 nm SiO2, H2 = 75 nm SiNx), a gold nanoantenna and a SiO2 cladding layer. The geometric parameters of the nanoantenna and cladding layer are optimized as follows: L = 390 nm, S = 130 nm, H = 70 nm for the nanoantennae, and HC = 320 nm for the cladding layer. The unit cells form a square lattice with a period of P = 600 nmCC BY · PubMed Central
Fig. 2 PCR performance and verification based on single-pixel PI-LCoS device. a Simulated PCR performance of the device for different wavelengths and refractive index of the LC material. b Schematic of the single-pixel PI-LCoS device for experimental verification. Measured PCR performance of the single-pixel device with different driving voltages corresponding to different refractive index of LC (c) and working wavelengths among C + L band (d). The L-band range is slightly limited by the available laser in the lab
Fig. 2 PCR performance and verification based on single-pixel PI-LCoS device. a Simulated PCR performance of the device for different wavelengths and refractive index of the LC material. b Schematic of the single-pixel PI-LCoS device for experimental verification. Measured PCR performance of the single-pixel device with different driving voltages corresponding to different refractive index of LC (c) and working wavelengths among C + L band (d). The L-band range is slightly limited by the available laser in the labCC BY · PubMed Central
Fig. 3 4K metasurface-embedded PI-LCoS device and its critical characteristics. a Photograph of the fabricated 4 K LCoS device (4160 × 2464 pixels), in which half of the area (4160 × 1232 pixels with 3.74 μm pixel size) as indicated in the black dashed box has embedded metasurface, so that performance of the PI-LCoS (area with metasurface) and original LCoS (area without metasurface) can be compared. An enlarged scanning electron microscope (SEM) image of the nanoantenna array is presented on the right. b Measured PCR performance of the PI-LCoS before and after LC packaging. Measured reflectivity (c) and phase response (d) of the original LCoS with 0° (LC alignment direction) linear-polarized incident light and PI-LCoS with both 0° and 90° linear-polarized incident light. The amount of phase shift in the original LCoS is halved for better comparison with that of the PI-LCoS
Fig. 3 4K metasurface-embedded PI-LCoS device and its critical characteristics. a Photograph of the fabricated 4 K LCoS device (4160 × 2464 pixels), in which half of the area (4160 × 1232 pixels with 3.74 μm pixel size) as indicated in the black dashed box has embedded metasurface, so that performance of the PI-LCoS (area with metasurface) and original LCoS (area without metasurface) can be compared. An enlarged scanning electron microscope (SEM) image of the nanoantenna array is presented on the right. b Measured PCR performance of the PI-LCoS before and after LC packaging. Measured reflectivity (c) and phase response (d) of the original LCoS with 0° (LC alignment direction) linear-polarized incident light and PI-LCoS with both 0° and 90° linear-polarized incident light. The amount of phase shift in the original LCoS is halved for better comparison with that of the PI-LCoSCC BY · PubMed Central
Fig. 4 Demonstration of two basic functionalities using the fabricated PI-LCoS device. a–d Schematic of beam steering (a) and the measured optical intensity distributions of different linearly polarized light after beam steering with diffraction angles from 1° to 4° (b). All images have the same intensity reference and position reference. Quantitative analysis of the beam-steering performance with total efficiency and polarization dependence (c) for different linearly polarized light with polarization angles at every 15° between 0° to 180° (0° corresponds to the direction of LC directors) (d). Holographic imaging of ‘4 K PI-LCOS’ logo (e) by the PI-LCoS (f) and the original LCoS (g) under two orthogonal linearly polarized input light (0° and 90° polarization). The scale bar for these holographic images is 5 mm in size
Fig. 4 Demonstration of two basic functionalities using the fabricated PI-LCoS device. a–d Schematic of beam steering (a) and the measured optical intensity distributions of different linearly polarized light after beam steering with diffraction angles from 1° to 4° (b). All images have the same intensity reference and position reference. Quantitative analysis of the beam-steering performance with total efficiency and polarization dependence (c) for different linearly polarized light with polarization angles at every 15° between 0° to 180° (0° corresponds to the direction of LC directors) (d). Holographic imaging of ‘4 K PI-LCOS’ logo (e) by the PI-LCoS (f) and the original LCoS (g) under two orthogonal linearly polarized input light (0° and 90° polarization). The scale bar for these holographic images is 5 mm in sizeCC BY · PubMed Central
Fig. 5 Demonstration of a 1 × 9 PI-WSS module based on PI-LCoS. Illustrations of a conventional 1 × 9 WSS based on an ordinary LCoS device (a) and an 1 × 9 PI-WSS based on the PI-LCoS device (b). FAU fiber array unit, Wol Wollaston prism, HWP half-wave plate, C-lens cylindrical lens. Performance of the assembled PI-WSS including IL (c) and PDL (d) for all the nine output ports in the C band
Fig. 5 Demonstration of a 1 × 9 PI-WSS module based on PI-LCoS. Illustrations of a conventional 1 × 9 WSS based on an ordinary LCoS device (a) and an 1 × 9 PI-WSS based on the PI-LCoS device (b). FAU fiber array unit, Wol Wollaston prism, HWP half-wave plate, C-lens cylindrical lens. Performance of the assembled PI-WSS including IL (c) and PDL (d) for all the nine output ports in the C bandCC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 36 references

Research works printed but not linked: 1

  1. Blanche, P. A. Holography, and the future of 3D display. Light Adv. Manuf. 2, 446–459 (2021).

Cited by

See all 57

Metadata

Authors
Zhu, Z., Wen, Y., Li, J., Chen, Y., Peng, Z., Li, J., Zhu, L., Wu, Y., Zhou, L., Liu, L., Zong, L., & Yu, S.
Affiliations
  • Sun Yat-sen University (CN)
  • Huawei Technologies (China) (CN)
  • Chinese Academy of Sciences (CN)
Corresponding author
  • Chen, Yujie
  • Zong, Liangjia
Venue
Light: Science & Applications
Published
2023-06-19
Volume
12
Issue
1
Pages
151-151
ISSN
2047-7538 (ISSN-L)
OpenAlex
W4381158453
Cited by
50
References
36
Citations by year
2026: 13 · 2025: 20 · 2024: 16 · 2023: 1
FWCI
3.02
Type
journal article
Language
en
Open access
Licence
Locations
  • Light Science & Applications (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Funders
  • National Natural Science Foundation of China (11774437, 61975202)
  • Sun Yat-sen University
  • Guangdong Provincial Pearl River Talents Program (2017BT01X121)
  • National Key Research and Development Program of China (2019YFA0706302, 2021YFB3600300, 2018YFB1801803)
  • Basic and Applied Basic Research Foundation of Guangdong Province (2021B1515120057, 2021B1515020093)
Topics
  • Physical Sciences › Materials Science › Electronic, Optical and Magnetic Materials › Metamaterials and Metasurfaces Applications
  • Physical Sciences › Engineering › Media Technology › Advanced Optical Imaging Technologies
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced Antenna and Metasurface Technologies
Keywords
liquid crystal on silicon, spatial light modulator, metasurfaces, polarization rotator, beam steering, holographic display, wavelength selective switch, telecom wavelengths

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Metasurface-enabled polarization-independent LCoS spatial light modulator for 4K resolution and beyond. https://app.cochat.ai/papers/10.1038/s41377-023-01202-6
The paper
Zhu, Z., Wen, Y., Li, J., Chen, Y., Peng, Z., Li, J., Zhu, L., Wu, Y., Zhou, L., Liu, L., Zong, L., & Yu, S. (2023). Metasurface-enabled polarization-independent LCoS spatial light modulator for 4K resolution and beyond. Light: Science & Applications. https://doi.org/10.1038/s41377-023-01202-6

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.