Ultralow detection limit and ultrafast response/recovery of the H2 gas sensor based on Pd-doped rGO/ZnO-SnO2 from hydrothermal synthesis
Open accessThe DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Abstract
Hydrogen (H 2) sensors are of great significance in hydrogen energy development and hydrogen safety monitoring. However, achieving fast and effective detection of low concentrations of hydrogen is a key problem to be solved in hydrogen sensing. In this work, we combined the excellent gas sensing properties of tin(IV) oxide (SnO 2) and zinc oxide (ZnO) with the outstanding electrical properties of reduced graphene oxide (rGO) and prepared palladium (Pd)-doped rGO/ZnO-SnO 2 nanocomposites by a hydrothermal method. The crystal structure, structural morphology, and elemental composition of the material were characterized by FE-SEM, TEM, XRD, XPS, Raman spectroscopy, and N 2 adsorption–desorption. The results showed that the Pd-doped ZnO-SnO 2 composites were successfully synthesized and uniformly coated on the surface of the rGO. The hydrogen gas sensing performance of the sensor prepared in this work was investigated, and the results showed that, compared with the pure Pd-doped ZnO-SnO 2 sensor, the Pd-doped rGO/ZnO-SnO 2 sensor modified with 3 wt% rGO had better hydrogen (H 2)-sensing response of 9.4–100 ppm H 2 at 380 °C. In addition, this sensor had extremely low time parameters (the response time and recovery time for 100 ppm H 2 at 380 °C were 4 s and 8 s, respectively) and an extremely low detection limit (50 ppb). Moreover, the sensor exhibited outstanding repeatability and restoration. According to the analysis of the sensing mechanism of this nanocomposite, the enhanced sensing performance of the Pd-doped rGO/ZnO-SnO 2 sensor is mainly due to the heterostructure of rGO, ZnO, and SnO 2, the excellent electrical and physical properties of rGO and the synergy between rGO and Pd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jiang, K., Xu, K., Zou, S., & Cai, W.-B. (2014) · Journal of the American Chemical Society · doi:10.1021/ja5008917 · Cited by 434 · cited 1×
“The main effects of rGO on gas sensing materials are as follows: (1) it forms a p-n heterojunction with an n-type metal oxide semiconductor, which increases the resistance of the material and increases the resistance change; (2) it has good conductivity and can detect small changes in electrical resistance caused by g…”
BackgroundSelf-citationDarmadi, I., Nugroho, F. A. A., & Langhammer, C. (2020) · ACS Sensors · doi:10.1021/acssensors.0c02019 · Cited by 382
Hydrogen sensor based on graphene/ZnO nanocomposite
Anand, K., Singh, O., Singh, M. P., Kaur, J., & Singh, R. C. (2014) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2014.01.029 · Cited by 315
A room-temperature NO2 gas sensor based on CuO nanoflakes modified with rGO nanosheets
Bai, H., Guo, H., Wang, J., Dong, Y., Liu, B., Xie, Z., Guo, F., Chen, D., Zhang, R., & Zheng, Y. (2021) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2021.129783 · Cited by 293
Wang, Z., Hou, C., De, Q., Gu, F., & Han, D. (2018) · ACS Sensors · doi:10.1021/acssensors.7b00896 · Cited by 268
Zhang, D., Sun, Y., Jiang, C., & Zhang, Y. (2017) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2016.11.005 · Cited by 237
One step synthesis of branched SnO2/ZnO heterostructures and their enhanced gas-sensing properties
Yang, X., Zhang, S., yu, Q., Zhao, L., Sun, P., Wang, T., Liu, F., Yan, X., Gao, Y., Liang, X., et al. (2019) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2018.10.138 · Cited by 236
Novel SnO2@ZnO hierarchical nanostructures for highly sensitive and selective NO2 gas sensing
Zhang, Z., Xu, M., Liu, L., Ruan, X., Yan, J., Zhao, W., Yun, J., Wang, Y., Qin, S., & Zhang, T. (2018) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2017.10.190 · Cited by 205
Singh, G., Virpal, & Singh, R. C. (2018) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2018.11.086 · Cited by 202
Bhati, V. S., Ranwa, S., Rajamani, S., Kumari, K., Raliya, R., Biswas, P., & Kumar, M. (2018) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.7b17877 · Cited by 185
An efficient hydrogen gas sensor based on hierarchical Ag/ZnO hollow microstructures
Agarwal, S., Kumar, S., Agrawal, H., Moinuddin, M. G., Kumar, M., Sharma, S. K., & Awasthi, K. (2021) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2021.130510 · Cited by 177
Nasresfahani, S., Sheikhi, M. H., Tohidi, M., & Zarifkar, A. (2017) · Materials Research Bulletin · doi:10.1016/j.materresbull.2017.01.032 · Cited by 143
Guo, W., Zhao, B., Zhou, Q., He, Y., Wang, Z., & Radacsi, N. (2019) · ACS Omega · doi:10.1021/acsomega.9b00734 · Cited by 138
Facile hydrothermal preparation of titanium dioxide decorated reduced graphene oxide nanocomposite
Huang, N. M., Chang, & Huang, N. M. (2012) · International Journal of Nanomedicine · doi:10.2147/ijn.s28189 · Cited by 132
Zhang, Z., Sun, T., Chen, C., Xiao, F., Gong, Z., & Wang, S. (2014) · ACS Applied Materials & Interfaces · doi:10.1021/am505911h · Cited by 127
Geng, X., Lu, P., Zhang, C., Lahem, D., Olivier, M., & Debliquy, M. (2018) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2018.11.123 · Cited by 122
Light-assisted recovery for a highly-sensitive NO2 sensor based on RGO-CeO2 hybrids
Hu, J., Zou, C., Su, Y., Li, M., Ye, X., Cai, B., Kong, E. S.-W., Yang, Z., & Zhang, Y. (2018) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2018.05.027 · Cited by 101
Highly sensitive sensors based on quasi-2D rGO/SnS2 hybrid for rapid detection of NO2 gas
Cheng, M., Wu, Z., Liu, G., Zhao, L., Gao, Y. L., Zhang, B., Liu, F., Yan, X., Liang, X., Sun, P., et al. (2019) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2019.04.074 · Cited by 98
Drmosh, Q. A., Yamani, Z. H., Hendi, A., Gondal, M. A., Moqbel, R., Saleh, T. A., & Khan, M. Y. (2018) · Applied Surface Science · doi:10.1016/j.apsusc.2018.09.128 · Cited by 96
rGO modified nanoplate-assembled ZnO/CdO junction for detection of NO2
Bai, S., Sun, X. H., Han, N., Shu, X., Pan, J., Guo, H., Liu, S., Feng, Y., Luo, R., Li, D., et al. (2019) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2019.121832 · Cited by 90
Li, Y., Deng, D., Chen, N., Xing, X., Liu, X., Xiao, X., & Wang, Y. D. (2017) · Journal of Alloys and Compounds · doi:10.1016/j.jallcom.2017.03.274 · Cited by 86
Low-temperature NO 2 gas sensor fabricated with NiO and reduced graphene oxide hybrid structure
Ngo, Y. T., & Hur, S. H. (2016) · Materials Research Bulletin · doi:10.1016/j.materresbull.2016.08.004 · Cited by 84
Henriquez, D. D. O., Cho, I., Yang, H. J., Choi, J., Kang, M., Chang, K. S., Jeong, C. B., Han, S. W., & Park, I. (2020) · ACS Applied Nano Materials · doi:10.1021/acsanm.0c02794 · Cited by 78 · cited 5×
“067= 0.047 ppm is calculated by Formula (3).”
BackgroundInfluentialHydrogen sensing properties of Pd/SnO2 nano-spherical composites under UV enhancement
Duan, P., Xiao, H., Wang, Z., Peng, Q., Jin, K., & Sun, J. (2021) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2021.130557 · Cited by 77
Self-citationChen, Z., Hu, K., Yang, P., Fu, X., Wang, Z., Yang, S., Xiong, J., Zhang, X., Hu, Y., & Gu, H. (2019) · Journal of Alloys and Compounds · doi:10.1016/j.jallcom.2019.152086 · Cited by 74
Self-citationEfficient room temperature detection of H2 gas by novel ZnFe2O4–Pd decorated rGO nanocomposite
Achary, L. S. K., Maji, B., Kumar, A., Ghosh, S. P., Kar, J. P., & Dash, P. (2020) · International Journal of Hydrogen Energy · doi:10.1016/j.ijhydene.2019.12.048 · Cited by 61
Hu, K., Wang, F., Shen, Z., Liu, H., Zeng, W., & Wang, Y. (2020) · Ceramics International · doi:10.1016/j.ceramint.2020.05.242 · Cited by 53
Enhanced ethanol sensing properties of ZnO-doped porous SnO2 hollow nanospheres
Ma, X., Song, H., & Guan, C. (2013) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2013.06.099 · Cited by 48
Sivakumar, R., Krishnamoorthi, K., Vadivel, S., & Govindasamy, S. (2021) · Diamond and Related Materials · doi:10.1016/j.diamond.2021.108418 · Cited by 47
The H 2 sensing properties of facets-dependent Pd nanoparticles-supported ZnO nanorods
Tang, Z., Zhang, Y., Deng, X., Dai, Y., Zhang, W., Fan, F., Qing, B., Zhu, C., Fan, J. Q., & Shi, Y. (2018) · Dalton Transactions · doi:10.1039/c8dt01980k · Cited by 42
Protonic Titanate Nanotube–Reduced Graphene Oxide Composites for Hydrogen Sensing
Yadav, S., Nair, A., Kusuma Urs, M. B., & Kamble, V. B. (2020) · ACS Applied Nano Materials · doi:10.1021/acsanm.0c02077 · Cited by 30 · cited 5×
“067= 0.047 ppm is calculated by Formula (3).”
BackgroundMethodInfluentialLin, B., Lin, S., Liu, Y., Luo, J., Gao, B., & Zhang, J. (2018) · Microporous and Mesoporous Materials · doi:10.1016/j.micromeso.2018.03.016 · Cited by 12
Cited by
Makhado, E., & Seleka, W. M. (2025) · Scientific Reports · doi:10.1038/s41598-025-13976-3 · Cited by 20
“The Pd-doped rGO/ZnO–SnO 2 nanocomposite sensor attains a notable limit of detection of 50 ppb (about 0.042 µM); nevertheless, its efficacy necessitates a substantial working temperature of 380 °C and the use of costly palladium 48 .”
Influential
Metadata
- Authors
- Zhang, X., Sun, J., Tang, K., Wang, H., Chen, T., Jiang, K., Zhou, T., Quan, H., & Guo, R.
- Venue
- Microsystems & Nanoengineering
- Published
- 2022-06-16
- Volume
- 8
- Issue
- 1
- Pages
- 67-67
- ISSN
- 2055-7434 (ISSN-L)
- OpenAlex
- W4283022161
- Cited by
- 202
- References
- 32
- FWCI
- 10.10
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.